HYLOLOGY HYL-2100 Particle Image Analysis System
The HYLOLOGY HYL-2100 particle image analysis system has a test range of 1 μm to 3500 μm, and the magnification of this model particle image analysis system is 4000 times. The HYL-2100 is a particle image analysis system suitable for material analysis laboratories in Universities & colleges and research institutes.
-
INESA WKL-722 Dust Morphology Carr Dispersibility Tester with Imported Microscope
$ 7350.31 -
INESA WKL-702 Particle image analyzer with China Microscope
$ 6577.33 -
JINGXIN JX-2000B Particle image analyzer test range: 0.5~ 3000μm
Login -
INESA WKL-728 Intelligent Dust Morphology Carr Dispersibility Tester with China Microscope
$ 8957.49 -
JINGXIN JX-2000A Particle image analyzer test range: 0.5~ 3000μm
Login
Introduction
HYL-2100 particle image analysis system is a multifunctional particle analysis system developed by Dandong Haoyu Technology Co., Ltd. The system consists of optical microscope, industrial CCD camera, computer, printer and image analysis software. Its basic workflow is as follows: 1. Take pictures of particles through optical microscope and video camera and transmit them to the computer; 2. Use special analysis software to process and analyze the images of particles; 3. Use computer display or printer output for analysis result. This system not only has the characteristics of intuition, image and accuracy, but also can directly observe the morphology of particles and obtain indicators such as particle size distribution, aspect ratio and sphericity. It provides an intuitive and visual means for particle analysis.
Features
1. This system uses the number of pixels contained in each particle in the particle image to make statistics, and calculates the isometric area and spherical volume of each particle. In this way, the iso-circular diameter and iso-spherical diameter of each particle are obtained, and then all the particles in the image are counted, and finally the particle size distribution and other information of the analyzed sample are obtained.
2. This system can perform grayscale conversion, segmentation, deletion, filling, scaling, smoothing, stitching and other processing on the image, and can also perform the above processing on multiple images at the same time, so as to improve the representativeness of the analyzed samples and make the processing results more accurate ,Honest and reliable.
3. After processing the image, the system can automatically count the number, area, volume, sphericity, aspect ratio, and particle size distribution data and graphics of the particles.
4. The original picture can be selected in the print report to make the test report more intuitive. At the same time, it can also print the data of particle size distribution, distribution curve, data information of each particle, aspect ratio, sphericity, etc.
Application
Research, processing and application of various metal powders, non-metal powders, and other powders. It is especially suitable for material analysis laboratories in colleges and universities and scientific research institutes.
hylology HYL-2100 Particle image analysis systemSpecifications
LIST | VALUE |
---|---|
test range | 1~3500μm |
Camera resolution | 2048 × 1536 pixels |
system magnification | 4000 times |
Repeatability error | < 2% (excluding error due to sample prepative factors) |
System resolution | 0.1 micron |
Digital Camera (CCD) | 5 million pixels |
Microscope | Microscope |
Ruler scale | 10μm |
Camera system | Maximum resolution 2048 × 1536; pixel size 2.2µm × 2.2µm; frame rate 5FPS; signal-to-noise ratio 40.5dB; sensitivity 0.53V/lux-sec; output mode USB2.0 |
calibration function | Use ruler calibration to make measurement results accurate |
Automatic segmentation, multiple images merge function | The software has automatic segmentation and manual segmentation functions, among which the automatic segmentation function is convenient, accurate and fast; the software adopts the function of merging multiple pictures to make up for the shortcomings of insufficient representation of the image particle size instrument |
analysis project | Particle size distribution, aspect ratio distribution, circularity distribution, monomer particles and particle groups, etc |
Automatic segmentation speed | < 1 second. Segmentation success rate: > 93% |
Software operating environment | Windows XP、Windows7 |
interface mode | USB mode |
Output item | Including original parameters (including sample information, test information, etc.), analytical data (including interval distribution, cumulative distribution, average diameter, aspect ratio, and aspect ratio distribution, etc.), distribution graphics (interval distribution histogram and cumulative distribution Linear dispersion, etc.) |
hylology HYL-2100 Particle image analysis system Packing list
OpticalMicroscopy X1, industrial digital CCD camera X1, image processing and analysis software X2, ultrasonic disperser X1, sample spoon X3, slide X1, coverslip X1, power strip X1, paper drawing X1, warranty card X1, manual X1, certificate X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.