HUITAI MJ-1000F-I Mold Incubator Volume 1000L
Huitai MJ-1000F-I Mold Incubator is a laboratory mold Incubator with a power of 4100W and a volume of 1000L. The MJ-1000F-I Mold Incubator adopts a large-screen LCD with a Temperature range of 0~ 65 ℃.
-
YIHENG BPN-80RHP CO2 Incubator 90 ℃ disinfection 80L/500W
$ 3854.31 -
YIHENG DHP-9402 Electric heated incubators of constant temperature 420L/1100W
$ 1778.75 -
HUITAI LRH-1000F Biochemical Incubator Volume 1000L
$ 5447.71 -
SANFA MHP-100E mildew incubator touch 100L
$ 1220.07 -
HONGKE GHP-160 intelligent lighting chamber 50 ℃ lighting chamber
$ 826.69
Overview
It is suitable for scientific research, colleges and production departments such as environmental protection, sanitation and epidemic prevention, drug inspection, agriculture and livestock, and aquatic products. It is a special constant temperature equipment for water body analysis and BOD determination, bacteria, mold, microorganism culture, preservation, plant cultivation and breeding test.
Features
1) Humanized design
⊕Large-screen LCD display, multi-group data display on one screen, menu-style operation interface, easy to understand and easy to operate. (standard configuration)
⊕Mirror stainless steel liner is adopted, the semi-circular arc design of the four corners is easy to clean, and the distance between the shelves in the box is adjustable.
⊕ Use 134 a, 406 a fluorine-free refrigerant, effective, energy-saving, and make the environment healthier!
⊕ There is a test hole with a diameter of 25mm/50mm on the left side of the box, which is convenient for experimental operation and temperature measurement. (optional)
2) Quality Assurance
⊕Adopt international brand compressors, self-developed compressor cooling system, which can effectively prolong the service life of the compressor.
⊕Using JAKEL pipe flow circulation fan, coupled with a uniquely designed air duct structure, creates a good air circulation system and effectively ensures the temperature uniformity in the box.
⊕PID control method, accurate temperature control and small fluctuation, with timing function, the maximum time setting value is 99 hours and 99 minutes.
◆Ultraviolet sterilization system
⊕Located on the top floor of the box, it can effectively kill floating bacteria in the circulating air in the box, thereby effectively preventing pollution during cell culture.
◆Intelligent LCD programmable multi-segment controller (optional)
⊕Programmable 15 sections and 30 steps can be preset, and the setting time of each section is 1~99 hours and 99 minutes.
⊕Multi-segment programmable control, which simplifies the complex test process and truly realizes automatic control and operation.
◆Independent temperature limit alarm system (optional)
⊕If the temperature exceeds the limit, the operation will be automatically interrupted, and the operator will be prompted by an audible and visual alarm. Ensure the safe operation of the experiment without accidents.
◆Convenient data processing (optional)
⊕Has a USB or RS485 interface, can be connected to a printer or a computer, and can record changes in temperature parameters. (optional)
Optional accessories
Intelligent program controller
Independent temperature limit controller
BOD special socket
Embedded printer
RS485 interface and special software
Test hole 25mm/50mm
HuiTai MJ-1000F-I Mold IncubatorSpecifications
LIST | VALUE |
---|---|
Temperature range | 0~65℃ |
Temperature uniformity | ±1.2℃ |
Temperature fluctuation | High temperature ± 0.3 ℃, low temperature ± 0.5 ℃ |
temperature resolution | 0.1℃ |
Liner size | 1050*590*1610mm |
volume | 1000L |
Load bracket (standard) | 3pcs |
Timer | 1~9999min |
Power | AC220V 50Hz/25A |
Input power | 4100W |
Dimensions | 1410x890x1950mm |
Optional accessories | Intelligent program controller, independent temperature limit controller, BOD special socket, embedded printer, RS485 interface and special software, test hole 25mm/50mm |
HuiTai MJ-1000F-I Mold Incubator Packing list
Complete-built unit X1, carrier X3, manual X1, certificate of conformity X1, warranty card X1