ZKHS QL-010 ozone aging test chamber ozone aging machine
ZKHS QL-010 ozone aging test chamber size 1000X1000X1000mm, Temperature range RT + 10 ℃~ 70 ℃, 0 ℃~ 70 ℃, Humidity range 65%~ 98% R.H, 40%~ 98% R.H, ozone concentration (low concentration) 10~ 1000PPhm, (high concentration) 1~ 500PPm, fluctuation +/- 10%.

-
ZKHS QL-500 ozone aging test chamber ozone aging test chamber
$ 13638.45 -
HYQL-150 Ozone Conditioning Test Chamber 100~ 1000pphm
Login -
HZAOC QL-100 Ozone Conditioning Test Chamber
$ 10052.25 -
ZKHS QL-100 ozone aging test chamber aging test for resistance to sunlight and artificial Light sources
$ 10741.90 -
HZAOC QL-500 Ozone Conditioning Test Chamber
$ 12412.40
Applications
◆The product is suitable for the aging test of sunlight resistance and artificial light source of non-metallic materials.
Cabinet structure
◆ The box body is processed and formed by CNC machine tools, the shape is beautiful and generous, and the box cover is the side buckle handle type, which is easy to operate.
◆ The inner tank of the box is made of imported stainless steel plate, and the shell of the box is sprayed with A3 steel plate, which increases the appearance texture and cleanliness.
◆ The heating method is heating wire, which heats up quickly and the temperature is evenly distributed.
Control system
◆ PT100 temperature sensor, imported instrument control heating, more stable temperature.
◆ The light can be controlled independently, and it can be controlled alternately.
◆ The light control time and the alternating control time can be set arbitrarily within 0~999H.
Meets standards
Strictly refer to: GB/T16777-2008, GB/T12967.4-2014 technical parameters design and manufacturing.
Series selection
Model | QL-100 | QL-150 | QL-225 | QL-500 | QL-010 |
Inner dimensions | 450X450X500 | 500X500X600 | 500X600X750 | 700X800X900 | 1000X1000X1000 |
Temperature range | RT+10℃~70℃、 0℃~70℃ | ||||
Humidity range | 65%~98%R.H 、 40%~98%R.H | ||||
Ozone concentration | (Low concentration) 10~1000PPhm, (High concentration) 1~500PPm, Volatility 10% | ||||
Temperature fluctuations | ±0.5℃ | ||||
Humidity fluctuations | +2、-3%R.H | ||||
Test setup | Dynamic, static (optional) | ||||
Sample frame speed | 360 degree rotation of the sample holder (1 revolution per minute) | ||||
Gas flow rate | 12~16mm/S | ||||
Temperature controller | Imported LED digital display P, I, D+S, S, R. microcomputer integrated controller | ||||
Time controller | High-precision hour, minute, and second time controllers | ||||
Ozone concentration analysis | Inlet concentration analysis regulator 4~20mA output, RS232 communication port | ||||
ozonizer | Silent discharge tube type | ||||
Security | Leakage, short circuit, overtemperature, motor overheating, overcurrent protection | ||||
Total power | 4.0KW | 4.5KW | 5.5KW | 6.5KW | 7.5KW |
Duration of the trial | 0~9999 M, H adjustable | ||||
Supply voltage | AC380V±10% 50Hz three-phase five-wire system |
ZKHS QL-010 Ozone aging test chamberSpecifications
LIST | VALUE |
---|---|
Interior size | 1000*1000*1000mm |
Temperature range | RT+10~70℃、 0~70℃ |
Humidity range | 65~98%R.H、40~98%R.H |
Ozone concentration range | (Low concentration) 10~ 1000PPhm, (high concentration) 1~ 500PPm, volatility +/- 10% |
Temperature stability | ±0.5℃ |
Humidity stability | +2、-3%R.H |
Sample state | Dynamic, static (optional) |
Rotation speed | 1Rpm 360 degree swirl/spin sample holder |
Flow velocity | 12~16mm/S |
temperature controller | Imported LED digital display P, I, D + S, S, R. Microcomputer integrated controller |
time controller | High-precision hour, minute, second time controller |
Ozone concentration analysis | Imported concentration analysis regulator 4~ 20mA output, RS232 communication port |
Ozone generator | Silent discharge tube |
Safety protection | Leakage, short circuit, overtemperature, motor overheating, overcurrent protection |
Power | 7.5KW |
Time setting range | 0~ 9999 M, H adjustable |
Power supply voltage | AC380V +/- 10% 50Hz three-phase five-wire system |
ZKHS QL-010 Ozone aging test chamber Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 2051-2023
- ActiveHG/T 5721-2020
- ActiveDIN 53508-2000
- ActiveGB/T 18173.1-2012
- ActiveISO 1431-1-2022
- ActiveDIN 53508-2020
- ActiveASTM D1149-2018
- ActiveGB/T 16777-2008