LEICI ZDJ-5B AutomaticTitrator
LEICI ZDJ-5B AutomaticTitrator supports Potentiometric titration, poten-tiometry, adopts valve Burette integrated design, direct replacement, effectively avoids interference, ZDJ-5B AutomaticTitrator titration analysis Repeatability 0.20%, titration capacity allowable error 10ml Burette : +/- 0.025ml; 20ml Burette : +/- 0.035ml, Burette resolution 1/30000.

-
LEICI ZDJ-4B Potentiometric titrator
$ 3693.64 -
HANNA HI933 Karl Fischer Volumetric (KF) Moisture Meter Potentiometric titrator
$ 9334.31 -
HANNA HI931 Automatic Potentiometric titration, poten-tiometry analyzer
$ 7992.75 -
HANNA HI934 Karl Fischer Coulomb Method (KF) Potentiometric titrator
$ 9334.31 -
LEICI ZDJ-4A Potentiometric titrator
$ 2697.05
Introduction
The titrator supports potentiometric titration. 7-inch color touch screen and navigation-style operation make titration testing simple and convenient. Can support two sets of titration lines (including one set of built-in titration lines and one set of optional external titration lines), which will be more convenient for users who need to frequently change titrants; supports direct connection to automatic samplers to achieve batch samples Automatic measurement can meet customersâ batch testing needs.
Product Description
7-inch color touch capacitive screen, navigation-style operation; real-time display of test methods, titration curves and measurement results;
Contains a set of built-in titration lines, which can be expanded to a second set of titration lines (optional, external);
It adopts the integrated design of valve and burette, which can be replaced directly to effectively avoid interference. It supports various burettes of 10mL and 20mL;
Supports various titration modes such as dynamic titration, isovolumetric titration, preset end point titration, constant titration and manual titration; supports acid-base titration, non-aqueous acid-base titration, redox titration, precipitation titration and complex titration, etc. method;
Calculation formulas can be defined and calculation results can be directly displayed; it supports the creation, editing, copying and querying of titration methods, and can store 100 sets of titration methods; 10 titration method shortcuts can be customized;
Support titrant management function;
Supports pH calibration and measurement functions;
Supports titration result recalculation function; supports data management, can store 200 sets of titration results that meet GLP requirements; supports data statistics function, allowing users to count, review, analyze, and compare titration results;
Supports Chinese/English operating languages; supports user management functions; supports power-off protection functions and self-diagnosis functions;
Supports USB and RS232 connection to PC, two-way communication, supports U disk plug-and-play, and comes with REX titration special software;
It can be directly connected to the automatic sampler to realize automatic measurement of batch samples.
LeiCi ZDJ-5B AutomaticTitratorSpecifications
LIST | VALUE |
---|---|
Titration Analysis Repeatability | 0.20% |
Allowable error of titration capacity | 10Ml Burette : +/- 0.025ml; 20ml Burette : +/- 0.035ml |
Burette resolution | 1/30000 |
Titration volume accuracy | 0.0001mL |
Burette infusion or rehydration rate | (55 +/- 10) s (when Burette is full) |
Measurement range | (-1999.99~1999.99)mV,(0.000~14.000)pH |
Resolution | 0.01mV,0.001pH |
Intrinsic error | pH:±0.01pH mV:±0.03%FS |
Stability | (+/- 0.3mV +/- 1 word)/3h |
Measurement range | (-5.0~105.0)℃ |
Resolution | 0.1℃ |
Intrinsic error | ±0.3℃ |
Power | AC (220 +/- 22) V; Frequency (50 +/- 1) Hz |
Dimensions | 340×400×400mm,10kg |
LeiCi ZDJ-5B AutomaticTitrator Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 3653.1-2024
- ActiveGB/T 43788-2024
- ActiveSN/T 2261-2009
- ActiveHB 20056.4-2011
- ActiveYB/T 159.3-2015
- ActiveYB/T 505.4-2007
- Active 178-2014
- ActiveYS/T 710.1-2009
- Active 5110.2-2000
- Active 0995-2019
- Active 0980-2019
- ActiveSH/T 0688-2000
- ActiveHG/T 3838-2008
- ActiveYC/T 314-2009
- ActiveSH/T 1767-2008
- Active 0836-2010
- Active 5092.4-2001
- Active
- ActiveSN/T 4951-2017
- ActiveSN/T 0254-2020