      YIHENG BPN-80RHP CO2 Incubator 90 ℃ disinfection 80L/500W

      High-grade CO2 Incubator, gas sleeve PID control heating, 80L volume, 90 ℃ high temperature heating and humidity sterilizing, with 2 shelves, color touch screen, imported infrared Sensors control, set high efficiency Filter.

      Brand
      SKU: NB038576
      China YiHeng
      Stock
      Loading…
      Price
      $ 3853.56
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • YiHeng BPN-80RHP Co2 incubatorOverview

        • Specifications
        • Comments
        • FAQs
        BPN-80RHP
        Co2 incubator
        • YIHENG BPN-80RHP CO2 Incubator 90 ℃ disinfection 80L/500W
        High-grade CO2 Incubator, gas sleeve PID control heating, 80L volume, 90 ℃ high temperature heating and humidity sterilizing, with 2 shelves, color touch screen, imported infrared Sensors control, set high efficiency Filter.

        Features

        1. Touch screen controller

        ●  Using super large touch screen screen, instead of the traditional button operation mode, it is easy to operate and edit programs. The controller operation interface is optional in Chinese and English.

        ● It can display real-time running curves, and has the function of curve summary. It can directly check the changes of three groups of curves of temperature, humidity and CO2 concentration in the same period of time, as well as abnormal alarm and door opening and closing information.

        ● After the data and test conditions are input, the controller has a screen lock function to avoid human touch instead of normal shutdown.

        ● 72-hour machine operation record query function, which is convenient for users to track abnormal conditions and trace historical operation information.

        ● Optional RS-485 communication interface, can design programs on the computer, monitor the experimental process and perform functions such as switching on and off.

        2. CO2 concentration control system

        ● Imported infrared (IR) sensor control

        If the door needs to be opened frequently during the experiment, the infrared sensor is a suitable choice. The imported infrared (IR) sensor selected by Yiheng is very sensitive to the change of CO2 concentration, and is not affected by other conditions inside the incubator impact on it. If you open the door for 30 seconds and then close the door, it can return to the set concentration of 5% CO2 within ≤3 minutes. Even if it is used by multiple people and needs to open and close the door frequently, it can still keep the CO2 concentration in the box fast, stable and uniform.

        3. Temperature control\monitoring system

        A. Incubator temperature control system

        ● Pt100 temperature detector to ensure accurate temperature inside the box. The heating power can be adjusted in real time to ensure the accuracy of the actual temperature in the box. After the user opens and closes the door to sample and stake out, the experimental temperature can be restored within 3 minutes.

        B. Door temperature heating system

        ● The outer box door has a heating function, and the door temperature follows the box temperature and is slightly higher than the box temperature, which can effectively prevent the glass door from condensing water, facilitate observation of the experiment process, and avoid the possibility of microbial contamination caused by the glass door condensing water sex.

        C. Ambient temperature monitoring system

        ● The independent ambient temperature detector can automatically adjust the heating , so as to avoid the overshoot of the temperature inside the chamber.

        D. Over-temperature protection system

        ● Standby temperature control system independent of the temperature control system of the CO2 incubator. When the temperature control system of the incubator fails and , when the temperature in the working room reaches the limit temperature setting value of the controller, the over-temperature protection system will Automatically cut off heating , and sound and light alarm.

        E. Power failure alarm system

        ● Real-time detection of the power supply status of the incubator. When there is a power failure or loss of power, an audible and visual alarm signal will be issued immediately, so that the incubator run safely and reliably without accidents.

        4. Sterilization system

        A. 90°C High Temperature Humid Heat Sterilization System (RHP)

        ● It can effectively sterilize the inner chamber (including temperature sensor, carbon dioxide concentration sensor, fan, partition and bracket) with high temperature and humidity, and effectively eliminate bacteria, mold, mycoplasma and other microorganisms caused by cell culture. Pollution, to provide users with a safe experimental environment.

        ● Simple operation: the user only needs to press the (sterilization start) button on the control panel, and the sterilization system can effectively sterilize all components in the box (including temperature sensor, carbon dioxide concentration sensor, fan, partition and bracket) of sterilization. The entire sterilization process takes 18 hours to ensure comprehensive and effective sterilization.

        B. UV sterilization system (RWP)

        ● The ultraviolet sterilizing lamp is located at the top and rear side of the box, which can regularly sterilize the inside of the box, effectively kill the circulating air in the box and the water vapor floating bacteria in the humidification water tray or the bottom slope water tray, thus effectively preventing cell culture. pollute.

        5. Automatic control of circulating fan speed

        ● The speed of the circulating fan can be automatically controlled. When the temperature in the box is at a constant temperature, the speed will decrease, and the circulating wind speed will be adjusted to the wind speed suitable for cell growth, so as to avoid volatilization of samples due to excessive air volume

        6. Effective filter

        A. Microbial effective filter

        ● The CO2 inlet is equipped with an effective microbial filter. For particles with a diameter ≥ 0.3 μm, the filtration efficiency is as high as 99.99%, and the bacteria and dust particles in the CO2 gas are effectively filtered.

        B. HEPA effective filter

        ● The gas quality in the CO2 incubator is an important indicator to measure the cell culture environment. The HEPA effective filter can effectively filter bacteria and dust particles in the outside air, eliminate and prevent cross-contamination between the outside air and the inner room of the incubator, and make the incubator It is kept sterile at all times. After the door is closed for 5 minutes, the air quality in the box can quickly return to the 100-level cleanliness level. The HEPA effective filter is easy to disassemble and assemble without tools.

        7. Safety function

        ● High temperature, low temperature and over-temperature alarm ● Box temperature sensor failure alarm    ● Door temperature sensor failure alarm

        ● Over-temperature sensor failure alarm    ● CO2 concentration is too high or too low alarm    ● Power failure alarm

        ● Independent temperature limit alarm    ● Too long door opening alarm    ● Disinfection and sterilization status reminder

        A. Hierarchical authority management (optional)

        ● There are multiple personal accounts that can be allocated. According to the needs of equipment management, the operation authority of the equipment controller can be assigned to three levels of authority: administrator , operator and guest. The touch screen also supports Chinese and English input, and the system can be logged in according to the actual name of the operator . At the same time, the system also has an operation log query function to record detailed operation logs of each user, which is convenient for equipment operation and maintenance management and audit trail.

        B. Data recording and fault diagnosis display (optional)

        ● All data can be downloaded to the computer through the RS485 port for storage, and when a fault occurs, the data .

        C. Wireless alarm system (SMS alarm system) (optional)

        ● If the equipment user is not on site, when the equipment fails, the system will collect the fault signal in time and send it to the mobile phone of the designated recipient through SMS to ensure timely troubleshooting and resume testing to avoid accidental losses

        VS

        YiHeng BPN-80RHP Co2 incubatorSpecifications

        LIST VALUE
        Power AC220V/50Hz
        Input power 500W
        Heating method Air jacket microcomputer PID control
        Temperature range RT+5~55°C
        Environment temperature +5~30℃
        Temperature fluctuation ±0 1℃
        CO2 control range 0~20%
        CO2 control accuracy +/- 0.1% (Infrared Sensors)
        CO2 recovery time (Open the door for 30 seconds to restore to 5%) ≤ 3 minutes
        temperature recovery (Open the door for 30 seconds and return to 37 ℃) ≤ 8 minutes
        Relative humidity Natural evaporation ≥ 90% (can be equipped with relative humidity digital display)
        volume 80L
        Liner size W × D × H 400mm×450mm×500mm
        Dimensions W × D × H 590mm×687mm×790mm
        Shelf 2 pieces (standard)
        UV Lamp Sterilization 90 ℃ high temperature heating and humidity disinfection (UV disinfection optional)

        YiHeng BPN-80RHP Co2 incubator Packing list

        host x1, instruction manual x1, packing list x1, certificate x1.

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
        +YiHeng BPN-80RHP Co2 incubator Big data