China CHP-80S Co2 incubator Water jacket 500W/80L
The high-performance Co2 incubator developed by the company's many years of technical experience and the introduction of new processes has fast heating and small temperature fluctuations.
-
YIHENG BPH-9402 Precision thermostatic incubator artificial thermostatic fostering experiment box
$ 2170.60 -
BENTING CBPX-70B biochemistry cultivating box 70L
Login -
Kenton SPX-250S Biochemical Incubator 250L
$ 978.22 -
Huitai LRH-250CB Low Temperature Incubator Volume 250L
$ 6145.69 -
SANFA SHP-250DB low temperature biochemistry cultivating box -40 ℃/250L
$ 3718.08
Applications
CHP-80S carbon dioxide incubator is an advanced equipment for culturing cells, tissues and bacteria. It is a key instrument necessary for carrying out immunology, oncology, genetics and bioengineering. It is widely used in the research and production of microorganisms, agricultural sciences, and pharmaceuticals.
Features
CHP-80S carbon dioxide incubator is a high-performance carbon dioxide incubator developed using advanced technology and new processes. The control accuracy of using infrared CO2 sensor is accurate and stable. It has the characteristics of fast heating and small error in temperature and CO2 concentration.
It adopts mirror stainless steel inner tank, which is easy to clean; it adopts door temperature heating system, which can effectively prevent condensation on the glass door inside the box, thus preventing the possibility of microbial contamination caused by condensed water.
The carbon dioxide incubator is composed of a plastic spray shell, a stainless steel working chamber and an electronic control part. A carbon dioxide cylinder and a carbon dioxide pressure reducing valve must be available during use. The carbon dioxide gas must be pure and the pressure of the pressure reducing valve must be stable. The carbon dioxide cylinder is a pressure volume and is prepared by the user. The pressure reducing valve is a special pressure reducing valve for carbon dioxide. Its performance directly affects the accuracy of the carbon dioxide concentration in the tank, so it is matched by our company.
1. The CO2 incubator has two heating methods: water jacket type and air jacket type, which can heat up quickly and have good uniformity.
2. The temperature sensor is Pt100 platinum resistor, which has good interchangeability.
3. The temperature control circuit uses two sensors: alarm and main control box temperature. Even if the main control circuit is out of control, the alarm circuit can still limit the temperature, greatly improving reliability.
4. The carbon dioxide input loop is uniquely designed and can be quickly restored after opening the door (for example: when the concentration is 5%, the recovery time does not exceed 6 minutes, and when the concentration is 10%, the recovery time does not exceed 12 minutes). The carbon dioxide concentration is input by the ratio of air and carbon dioxide. The concentration Not affected by humidity, etc.
5. The humidity is natural evaporation.
6. It adopts a double door structure, the outer door adopts a magnetic door seal structure, and the inner chamber glass door and box adopt silicone rubber sealing strips, which has good sealing performance, avoids contamination and facilitates observation.
Domestic CHP-80S Co2 incubatorSpecifications
LIST | VALUE |
---|---|
volume | 80L |
Humidity control range | RT+5~60℃ |
Temperature stability | ±0.5℃ |
Temperature uniformity | ±0.3℃ |
temperature recovery time | ≤ 15 minutes (at 37 ℃) |
Carbon dioxide control range | 0-20%V/V |
Carbon dioxide concentration recovery time | Concentration value × 1.2 minutes |
Power | 220V 50HZ |
Power | ≤500W |
Working temperature | 5~35℃ |
Liner size | 400*400*500mm |
Dimensions | 550×510×840 |
Heating method | natural evaporation |
Heating mode | water jacket |
Relative humidity | ≤85%RH |
Domestic CHP-80S Co2 incubator Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.