China CHP-160S Co2 incubator Water jacket 160L/700W
Fast heating, small temperature fluctuations, fast heating, good uniformity; mirror stainless steel liner, easy to clean; door temperature heating system, can effectively prevent the condensation of the Glass door in the box, thereby preventing the possibility of microbial contamination caused by condensate.
-
JINGQI CHP-80 Co2 incubator water jacket type
$ 1680.79 -
YIHENG BPN-80CRH Co2 incubator 80L/500W
$ 3480.83 -
HONGKE GHP-800 intelligent lighting chamber Biological lighting chamber
$ 2256.31 -
TAISITE MJX-250BIII mildew incubator Manual humidity control 250L
$ 1145.06 -
Guohua 150C Digital Illumination Incubator 150L
$ 868.02
Applications
CHP-160S carbon dioxide incubator is an advanced equipment for culturing cells, tissues and bacteria. It is a key instrument necessary for carrying out immunology, oncology, genetics and bioengineering. It is widely used in the research and production of microorganisms, agricultural sciences, and pharmaceuticals.
Features
CHP-160S carbon dioxide incubator is a high-performance carbon dioxide incubator developed using advanced technology and new processes. The control accuracy of using infrared CO2 sensor is accurate and stable. It has the characteristics of fast heating and small error in temperature and CO2 concentration. It adopts mirror stainless steel inner tank and is easy to clean. The door temperature heating system can effectively prevent condensation on the glass door inside the box, thus preventing the possibility of microbial contamination caused by condensed water.
The CO2 incubator has two heating methods: water jacket type and air jacket type, which can heat up quickly and have good uniformity.
The temperature sensor is Pt100 platinum resistor, which has good interchangeability.
The temperature control circuit uses two sensors: alarm and main control box temperature. Even if the main control circuit is out of control, the alarm circuit can still limit the temperature, greatly improving reliability.
The carbon dioxide input loop is uniquely designed and can be quickly restored after opening the door (for example: when the concentration is 5%, the recovery time does not exceed 6 minutes, and when the concentration is 10%, the recovery time does not exceed 12 minutes). The carbon dioxide concentration is input by the air and carbon dioxide ratio, and the concentration is not affected by the Humidity and other effects.
Humidity is natural evaporation.
It adopts a double door structure, the outer door adopts a magnetic door seal structure, and the inner chamber glass door and box adopt silicone rubber sealing strips, which has good sealing performance, avoids contamination and facilitates observation.
Factory CHP-160S Co2 incubatorSpecifications
LIST | VALUE |
---|---|
volume | 160L |
Humidity control range | RT+5~60℃ |
Temperature stability | ±0.5℃ |
Temperature uniformity | ±1℃ |
temperature recovery time | ≤ 15 minutes (at 37 ℃) |
Carbon dioxide control range | 0-20%V/V |
Carbon dioxide concentration recovery time | Concentration value × 1.2 minutes |
Power | 220V 50HZ |
Power | ≤700W |
Working temperature | 5~35℃ |
Liner size | 500*500*650mm |
Dimensions | 650×610×990 |
Heating method | natural evaporation |
Heating mode | water jacket |
Relative humidity | ≤85%RH |
Factory CHP-160S Co2 incubator Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Introduction to the principle, characteristics and application scenarios of shock incubator
- Principles and selection methods of various laboratory incubators