China CHP-160Q Co2 incubator 160L/700W
Volume 160L, humidity control range RT + 5~ 60 ℃, Temperature stability +/- 0.5 ℃, Temperature uniformity +/- 1 ℃, temperature recovery time ≤ 15 minutes (37 ℃), carbon dioxide control range 0-20% V/V, carbon dioxide concentration recovery time concentration value × 1.2 minutes
Equipment introduction
The new generation CHP series carbon dioxide incubator is a high-performance carbon dioxide incubator developed by the company's many years of technical experience and the introduction of new processes. It has the characteristics of fast heating and small temperature fluctuation: it is ideal for carrying out immunology, oncology, genetics and biology. The key equipment necessary for engineering is widely used in the research and production of medicine, microbiology, agricultural science, and pharmacology.
This machine is a desktop carbon dioxide incubator, which is composed of a plastic spray shell, a stainless steel working chamber and an electronic control part. A carbon dioxide cylinder and a carbon dioxide pressure reducing valve must be available during use. The carbon dioxide gas must be pure and the pressure of the pressure reducing valve must be stable. The carbon dioxide cylinder is a pressure volume and is prepared by the user. The pressure reducing valve is a special pressure reducing valve for carbon dioxide. Its performance directly affects the accuracy of the carbon dioxide concentration in the tank, so it is matched by our company.
Features
1. The CO2 incubator has two heating methods: water jacket type and air jacket type, which can heat up quickly and have good uniformity.
2. The temperature sensor is Pt100 platinum resistor, which has good interchangeability.
3. The temperature control circuit uses two sensors: alarm and main control box temperature. Even if the main control circuit is out of control, the alarm circuit can still limit the temperature, greatly improving reliability.
4. The carbon dioxide input loop is uniquely designed and can be quickly restored after opening the door (for example: when the concentration is 5%, the recovery time does not exceed 6 minutes, and when the concentration is 10%, the recovery time does not exceed 12 minutes). The carbon dioxide concentration is input by the ratio of air and carbon dioxide. The concentration Not affected by humidity, etc.
5. The humidity is natural evaporation.
6. It adopts a double door structure, the outer door adopts a magnetic door seal structure, and the inner chamber glass door and box adopt silicone rubber sealing strips, which has good sealing performance, avoids contamination and facilitates observation.
Factory CHP-160Q Co2 incubatorSpecifications
LIST | VALUE |
---|---|
volume | 160L |
Humidity control range | RT+5~60℃ |
Temperature stability | ±0.5℃ |
Temperature uniformity | ±1℃ |
temperature recovery time | ≤ 15 minutes (at 37 ℃) |
Carbon dioxide control range | 0-20%V/V |
Carbon dioxide concentration recovery time | Concentration value × 1.2 minutes |
Power | 220V 50HZ |
Power | ≤700W |
Working temperature | 5~35℃ |
Liner size | 500*500*650mm |
Dimensions | 650×610×990 |
Heating method | natural evaporation |
Heating mode | Air sleeve |
Relative humidity | ≤85%RH |
Factory CHP-160Q Co2 incubator Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Introduction to the principle, characteristics and application scenarios of shock incubator
- Principles and selection methods of various laboratory incubators