JINGKELIAN QND-4D Portable Viscometer GB1723-79 Standard 4mm caliber for Coatings, paints Viscosity measurement
GB/T1723 coated 4 standard cup, 4mm standard diameter, portable, suitable for Viscosity measurement at the production and processing site of Coating paints.
-
Pushen ISO-6 #flow cup with bracket, aluminum material
710.0 RMB -
PUSHEN Zahn-5 #Zahn Cup
330.0 RMB -
China Ford-5 #Ford viscosity cup, flow hole 5.20mm
550.0 RMB -
Pushen Ford-1 #Ford viscosity cup Aluminum single cup
460.0 RMB -
MODERNER ISO-6 ISO flow cup
720.0 RMB
Picture show
Jingke QND-4D Portable Viscometer is a portable Tu 4 viscosity cup with a handle, which meets the national standard GB1723 and is designed with stainless steel. QND-4D portable viscometer is suitable for coatings, paints, varnishes, inks and other industries. NBCHAO Mall presents the QND-4D portable viscometer comprehensively in terms of specifications, Details, applications, etc. See the figure below for details:
Introduction to QND-4D Portable Viscometer
The QND-4D portable viscometer is a product designed and manufactured according to the QB1723-79 standard. The portable viscometer belongs to the workshop control test instrument. outflow time. (QND-4D portable viscometer hereinafter referred to as viscometer)
Operation method of portable viscometer
1. Before the test, first check whether the connection of the lifting beam is reliable and whether it can rotate freely.
2. Wipe the interior of the viscosity cup with gauze or absorbent cotton with the solvent used for the sample, especially the outlet part, and observe it with light until it is wiped clean.
3. Intrude the instrument into the liquid to be tested, lift the lifting beam with one finger and quickly lift the upper plane of the container cup away from the liquid surface, and at the same time start the stopwatch for timing. When the first drop appears in the middle of the sample wire, stop the stopwatch. The time is the full settling time of the measured liquid, that is, the conditional viscosity of the measured liquid.
4. For the conditional viscosity value of the same liquid, the arithmetic mean value should be calculated after three times, but the difference between each measurement should not be greater than 3% of the mean value.
5. After use, the viscometer should be cleaned and wiped clean for storage.
Calibration of Portable Viscometer
Multiplying the viscosity t1 measured by the effective viscometer by the correction coefficient k is the conditional viscosity t measured by the viscometer as shown in the following formula: t=k.tl
There are two ways to obtain the value of k:
1. Quasi-viscosity method: First, prepare more than five kinds of mixed oils of aviation oil and transformer oil with different viscosities, and measure the time of flowing out in the standard viscometer and the effective positive viscometer respectively at 25±0.2°C to obtain A series of time ratios k1, k2, k3, ..... The calculated average value of the two viscometers is the correction coefficient k.
2. Viscosity motion method: when there is a lack of viscous liquid, the t value is calculated according to the following formula:
Tu-1 viscometer: t=0.53n+1.0
Tu-4 viscometer: t]=0.223n+6.0
n is the kinematic viscosity (centistokes) of the mixed oil of aviation oil and transformer oil measured according to GB265-75 "Viscometer Measurement Method" at 25±0.1°C. The self-reported average value of a series of t1 ratios is the kw value. (1 centistoke = 1×10)
JingKeLian QND-4D Painted 4 Viscometer (Portable)Specifications
LIST | VALUE |
---|---|
outflow time | 10~150s |
Flow hole diameter | 4mm |
capacity | 100ml |
Cup body material | stainless steel |
Filter material | stainless steel |
Applicable standard | GB/T 1723 |
Environment temperature | 25±0.1℃ |
certificate | without |
Outlet height | 4±0.02mm |
JingKeLian QND-4D Painted 4 Viscometer (Portable) Packing list
Viscosity cup x1, Plastic Encasement Box with Shockproof Cotton x1, Instruction Manual x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
JingKeLian QND-4D Painted 4 Viscometer (Portable) Comment
FAQ
- Discussion on the calibration method of coating-4 viscosity cup
- Principle and application of floor coatings viscosity measurement instrument
- Principle, Characteristics and Application of QND Viscometer
- Introduction of Several Methods for Determination of Relative Viscosity
- Viscosity Conversion Tool - Required by the Viscosity Industry
- Should the Viscosity cup be portable or desktop?
- Viscosity cup operation application instructions
- What is dip coating? How to dip coating?
- Determination of Coating Viscosity
- Determination of Coating Viscosity
- ActiveJB/T 3078-2015
- ActiveGB/T 1727-2021
- ActiveGB/T 17001.6-2022
- ActiveHG/T 5187-2017
- ActiveHG/T 3369-2003
- ActiveHG/T 3349-2003
- ActiveCY/T 205-2019
- ActiveGB/T 13217.4-2020
- ActiveQB/T 5477-2020
- ActiveJT/T 821.4-2011
- ActiveJT/T 821.3-2011
- ActiveJT/T 821.2-2011
- ActiveJJG 743-2018
- ActiveHG/T 3830-2006
- AbolishGB/T 13217.4-2008
- ActiveQB/T 1046-2012
- ActiveGB/T 1723-1993
- ActiveJC/T 423-1991
- ActiveGB/T 4653-1984
- ActiveHG/T 2005-1991