YUEPING NDJ-8S swirl/spin Viscometer is used in grease, paints, plastics, accessories, Coatings, detergents, etc
Digital display, Measurement range 10~ 2000000mpa.s, rotor specifications 1 #, 2 #, 3 #, 4 #(0 #optional), Rotor velocity 0.3/0 6/0.5/3/6/12/30/60rpm, Measurement accuracy +/- 2% F.S
-
Pingxuan NDJ-1 rotational viscometer
1500.0 RMB -
JINGTIAN SNB-AI digital display Rotational Viscometer 10 million CP
7650.0 RMB -
JINGTIAN SNB-1 Digital display Rotational Viscometer with ultra-low viscosity adapter
5900.0 RMB -
CNSHP SNB-2 digital rotational viscometer viscosity up to 2000000mPa.s
3010.0 RMB -
NIRUN 60000 series, standard solution (not sold separately)
1200.0 RMB
Picture show
NDJ-8S Rotational Viscometer Overview
Yueping NDJ-8S rotational viscometer is equipped with 1st, 2nd, 3rd, 4th rotor and 8-speed digital display rotational viscometer, controlled by microcomputer technology, it is very convenient to set the range, and it is detected by the built-in sensor The measured data is processed, and finally the measured rotor number, speed, viscosity value, full scale percentage value and other parameters are displayed on the real screen, which is clear and intuitive. NDJ-8S rotational viscometer has a larger measurement range than NDJ-5s, and the measurement range is 10~2×10 6 mpa.s.
The rotational viscometer is a viscometer used to measure the absolute viscosity of Newtonian liquids and the apparent viscosity of non-Newtonian liquids. Measurement. NDJ-8S rotational viscometer has the characteristics of high measurement sensitivity, reliable test results, convenient use and operation, and beautiful appearance.
Principle
NDJ-8S is a digital display viscometer, the motor drives the rotor to rotate at a constant speed through variable speed. When the rotor rotates in the liquid, the liquid will generate a viscous moment acting on the rotor. The greater the viscosity of the liquid, the greater the viscous moment; conversely, the smaller the viscosity of the liquid, the smaller the viscous moment. The viscous moment acting on the rotor is detected by the sensor, and the viscosity of the measured liquid is obtained after computer processing.
Comparison of NDJ-5S and NDJ-8S parameters
model | NDJ-5S | NDJ-8S |
Measuring range | 10~2×10 5 mpa.s | 10~2×10 6 mpa.s |
Rotor Specifications | No. 1, 2, 3 and 4 rotors (optional No. 0 rotor can measure low viscosity to 0.1 mpa.s) | |
Rotor speed | 6, 12, 30, 60 rpm | 0.3, 0.6, 0.5, 3, 6, 12, 30, 60 rpm |
Automatic | Can automatically select the appropriate speed or prompt the rotor number | |
Reading Stable Cursor | When the vertical bar cursor is full, the displayed reading is basically stable | |
measurement accuracy | ±2% (Newtonian liquid) | |
Power supply | AC 220V±10% 50Hz±10% | |
working environment | Temperature 5℃—35℃, relative humidity not more than 80% | |
Dimensions | 370×325×280mm | |
net weight | 6.8kg |
Features
1. NDJ-8S digital viscometer is an upgraded product of Yueping rotational viscometer.
2. NDJ-8S digital viscometer adopts professional mechanical design technology, manufacturing process and microcomputer control technology, and the data collection is correct.
3. The display adopts blue backlight and high-brightness LCD display, and the data display is clear.
YuePing NDJ-8S ViscometerSpecifications
LIST | VALUE |
---|---|
Display mode | digital explicit |
Measurement range | 10~2000000mpa.s |
Rotor specification | 1 #, 2 #, 3 #, 4 #(0 #optional) |
Rotor velocity | 0.3/0.6/0.5/3/6/12/30/60rpm |
Measurement accuracy | ±2%F.S |
Power supply voltage | AC 220V +/- 10% 50Hz +/- 10% |
Operating temperature | 5~35℃ |
Dimensions | 370*325*280mm |
Weight | 6.8kg |
Automatic scan function | Can automatically select the appropriate Rotation speed or prompt the rotor number |
Readout stability cursor | When the vertical bar cursor is full, the display reading is basically stable |
Allowable relative humidity | ≤80% |
YuePing NDJ-8S Viscometer Packing list
host x1, (No. 1, 2, 3, 4) rotor x1, bracket x1, power adapter x1, base x1, lifting column x1, manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
YuePing NDJ-8S Viscometer Comment
FAQ
- Viscosity measurement for food and manufacturing
- Two different viscosity measurement methods
- Water-bomecoating formulation design basics
- Viscometer applications, classification, range and selection factors
- Viscosity cup operation application instructions
- How does temperature in liquids and gases change their viscosity?
- Introduction of Several Methods for Determination of Relative Viscosity
- Formulation and Preparation Method of Self-cleaning Coating Based on Modified Hydrophobic SiO _ 2
- Viscosity measurement in food production and processing
- Measurement and Application of Swirl/spin Viscometer
- ActiveGB/T 13217.4-2020
- ActiveGB/T 22427.7-2008
- ActiveGB/T 12004.4-2003
- AbolishGB/T 18856.4-2002
- ActiveSN/T 2903-2011
- ActiveGB/T 17473.5-2008
- AbolishGB/T 11175-2002
- AbolishGB/T 2794-2013
- ISO 2884-2-2003
- ActiveJB/T 9357-1999
- ActiveGB/T 22235-2008
- ActiveGB/T 10247-2008