PH value of hydrogen ion concentration in aqueous solution measured by AOLILONG PHS-2C digital acidity meter
AOLILONG PHS-2C digital acidity meter PH measurement range 0~ 14.00pH, PH measurement accuracy +/- 0.02PH, temperature compensation (0~ 60) ℃, input Impedance ≥ 1012Ω, use conditions Working temperature 0~ 45 ℃, relative humidity ≤ 85% RH; ORP measurement accuracy +/- 0.1% F. S, ORP measurement range 0~ +/-1999mV.
-
Basic PHB-5 pen pHmeter Economical pen pHmeter
280.0 RMB -
Online ph acidity meter AOLILONG PHG-2 industrial acidity meter
1080.0 RMB -
PhS-25CW-CN laboratory pHmeter desktop acidity meter
780.0 RMB -
LEICI 212 reference electrode
98.0 RMB -
Kodilda CT-1001C PH electrode with temperature probe NTC10K
499.0 RMB
Picture show
PHS-2C Digital Acidity Meter Description
Orilon PHS-2C digital acidity meter is a knob-type laboratory desktop acidity meter with a white backlight function. The measured pH value range is 0~14.00pH, which meets the testing needs of most laboratories. In addition, the PHS-2C digital acidity meter has a novel and fashionable appearance and structure, a white shell, a large LCD, and a clear and intuitive display.
Orilon PHS-2C digital acidity meter is a digital display acidity meter. The calibration method is two-point calibration. It is equipped with E201-9. It can accurately measure the pH value of hydrogen ion concentration in aqueous solution. It is often used in laboratory testing. Solution acid value can be used in chemical industry, scientific research, quality inspection, environmental protection and other fields, with accurate measurement and novel appearance.
PHS-2C digital acidity meter display diagram
AOLILONG PHS-2C Digital acidity meterSpecifications
LIST | VALUE |
---|---|
PH measurement range | 0~14.00pH |
PH measurement accuracy | ±0.02PH |
Temperature measurement range | 0~60℃ |
Impedance | ≥1012Ω |
Working temperature | 0~45℃ |
mV measurement accuracy | ±0.1%F.S |
mV measurement range | 0~±1999mV |
Allowable relative humidity | ≤85%RH |
Power | AC(220±22)V(50±0.5)Hz |
AOLILONG PHS-2C Digital acidity meter Packing list
Host x1, electrode x1, manual x1, Encasement box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
AOLILONG PHS-2C Digital acidity meter Comment
FAQ
- Detailed steps for pH determination of solutions
- Experimental water mass inspection
- Preparation method of polyaniline anti-corrosion coating
- A brief analysis of the history of pH paper
- Classification of common acidity meters on the market
- Maintenance technology of acidity meter (detailed introduction)
- Acidity meter - principle and use of laboratory acidity meter
- What are the inspection equipment required for emulsion paint?
- Detection principle of pH value
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- ActiveGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010
- ActiveGB/T 2390-2013
- ActiveGB/T 3780.7-2016
- ActiveGB/T 14518-1993
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 41166-2021
- ActiveGB/T 5541-2017
- ActiveGB/T 34676-2017
- ActiveGB/T 22374-2018
- ActiveGB/T 21894-2008
- ActiveHG/T 5164-2017