YUWEN GGL-10 industrial grade economical temperature recorder, widely used in GSP and GMP certification, only measurement and recording of temperature data
The YUWEN GGL-10 industrial-grade economical temperature recorder is dedicated to recording temperature data, with a range of -35 to 80 ° C. The GGL-10 temperature recorder can store 32,000 readings, with an LCD, and professional analysis software.
-
Yuwen YET-710L High Precision Platinum Resistance Thermometer, Single Channel
980.0 RMB -
Yuwen YET-710 High Precision Thermometer -200~ 800 ℃
899.0 RMB -
Yuwen YET-620L Dual Channel High Precision Thermocouple Thermometer
680.0 RMB -
CEM DT-3891G multi-function temperature tester
1050.0 RMB -
Smart Sensor ST1008A 8-channel thermocouple temperature recorder
1350.0 RMB
Picture show
Product Description
Yuwen GGL-10usb temperature recorder only measures and records temperature data. Unlike the GGL20 model, it cannot measure humidity data. Similarly, the GGL-10usb temperature recorder allows users to display dew point data curves through software. The accompanying analysis software DGraph allows users to easily set up records, download data, and perform professional curve display and analysis. DGraph analysis software supports functions such as setting records, downloading data, and performing professional curve display and analysis. Multiple data can be compared and analyzed at the same time, and user unit customization and custom data curve output can be supported. The recording alarm limit can be set. If the USB temperature recorder exceeds this limit, the alarm will be indicated by LED. The USB temperature recorder has an LCD, which can easily check the recording status. At the same time, when in non-recording mode, it can be used as a portable measuring instrument. This temperature recorder can easily set the recording interval, set the data download password, and select the start and end methods. The flexible design method better meets the professional needs of users.
Product display picture
Features
1. Ultra-portable, precise, easy to use, and cost-effective;
2. GGL-10usb temperature recorder is widely used in GSP and GMP certification, as well as temperature and humidity recording and monitoring of medicines, food, medicine cabinets, and cool cabinets;
3. High and low alarm limits can be set, and a light alarm can be issued if the limit is exceeded;
4. Optional extended probe;
5. The USB interface is directly connected to the computer;
6. Each recorder has a unique serial code, and multiple recorders can be compared and analyzed on the same curve interface;
7. Users can enter a password to limit data download permissions;
8. Equipped with DGraph software, it can easily complete settings, downloads, curve display, and data output.
9. Users can easily perform two-point calibration;
10. Extra long battery life, the battery can be replaced, and the data will not be lost when the battery is exhausted;
11. Users can customize the curve;
12. Users can customize units;
13. Users can name the channel individually and choose to close or open it;
14. The operation is very simple and can be used quickly.
Application
1. Temperature and humidity recording, monitoring, and SMS alarm for cool cabinets and medicine cabinets.
2. Cold chain transportation, logistics and warehousing of temperature and humidity sensitive items.
3. Drug GSP/GMP.
4. Scientific research, agriculture, plant and climate research.
Standard accessories
CD (1 piece), battery (1 piece), manual (1 piece)
Structure diagram
Key Description
The GGL-20 temperature and humidity recorder has only one button. Different operations can achieve different functions. Please refer to the following instructions for details:
1. When setting up the temperature and humidity recorder, if the user selects the button start method, after the setting is completed, the user can press and hold the button until the green LED lights up and the recorder starts recording.
2. When setting up the temperature and humidity recorder, if the user selects the button end mode, then when the temperature and humidity recorder is in the recording state, the user presses and holds the button until the green LED lights up, and the temperature and humidity recorder will stop recording.
LCD liquid crystal display
Users can activate the LCD display and switch display channels by pressing the button continuously. Without any key operation, the LCD will automatically turn off within 30 seconds. Please refer to the following description for LCD indication:
1. Real-time reading display.
2. If displayed, it indicates that the recorder is recording.
3. If displayed, it indicates that the data recorded by this channel exceeds the upper limit alarm value.
4. If displayed, it indicates that the data recorded by this channel exceeds the lower limit alarm value.
Note: The LCD will not display properly below -10 degrees Celsius.
LCD instruction sheet
Steps
Step 1: Battery installation
Unless you plan to use USB power, please install the battery before starting. Users can take it out of the packaging. In addition, users can also purchase replacement batteries from dealers. Please install the battery as shown below.
Step 2: Driver and software installation
Please put the supporting CD into the computer's optical drive, double-click the optical drive, and click USBXpressInstaller.exe in the "Driver" folder to start the driver installation. The user will first see the "Silicon LaboratoriesUSBXpress Device Driver Installer" dialog box. Please click the "Install" button to start. Install the driver until the "Success" dialog box appears, click the "Confirm" button. Subsequently, click setup.exe under the "Software" folder in the CD to start installing the software. The user follows the prompts and clicks "Next" until the installation is completed. After the software installation is completed, please insert the recorder into the computer USB interface to prepare the recorder settings. .
Step 3: Recorder setup and startup
Please follow the steps below to make the necessary settings for the recorder and start the recorder:
1. Make sure the temperature and humidity recorder has the battery installed correctly and plugged into the computer USB interface. If direct USB power supply is required, the battery does not need to be installed.
2. Double-click the "Data Logger Graph" icon on the desktop to run the program.
3. Click the green "Start" button on the toolbar to enter the "Logger Settings and Download" dialog box. Observe the "Logger Device Information and Status" on the left side of the dialog box. If the temperature and humidity recorder device serial number and device description are displayed correctly , recorder status, and battery status, it indicates that the device is correctly connected to the computer, otherwise the user needs to check the recorder connection or whether the driver is correctly installed.
4. Click "Settings" on the right to enter the settings dialog box, and set the current recorder name, sampling interval, and access password in "Basic Settings". In "Channel Settings", double-click the specified cell, and the user can set the upper and lower alarm limits of each channel, whether to turn on the red LED alarm, whether to turn on the alarm hold function, enable and disable channels, etc. In "Recording start and end mode", users can choose the recording start and end mode according to actual usage. All the above settings can also be directly used as factory default settings. After all settings are confirmed, the user should click the "Settings" button at the bottom right of the dialog box to officially take effect, or "Cancel" to exit the settings directly.
5. After the setting is completed, the recorder will start working according to the working mode set by the user. Users can pull out the temperature and humidity recorder and place it in a specific measurement and recording environment. Please note that if the start method selects button start, the user should not forget to use the button to start after arriving at the site.
Step 4: Data Download
Please follow the steps below to download the data to your computer:
1. Make sure the recorder is properly connected to the computer.
2. Click the green "Start" button on the toolbar of the main interface of the software to enter the "Logger Settings and Data Download" dialog box. Observe whether the description of "Logger Device Information and Status" is normal. If it is normal, it means that the device is connected normally. Otherwise, it should Check the device connection or whether the driver is installed correctly.
3. Click the "Download" button and select the data download directory according to the prompts. After the data download is completed, the curve graph can be opened and displayed directly.
Step Five: Curve Graph
1. Open the document through "File->Open" (or the "Open" button on the toolbar), and the curve corresponding to the document will be displayed.
2. Enlargement and reduction methods. Zoom in: Place the mouse on a certain point in the curve area, hold down the left mouse button, and drag a square area in any direction, the area will be enlarged and displayed. Zoom out: Please use the "Return to Previous" button on the toolbar to return to the previous display area, or click "Return to All" to directly return to the starting default display area.
3. Translation method. Move the mouse to the curve area, hold down the middle mouse button and move in any direction, and the curve will follow the movement.
4. Zoom in, zoom out and pan in fixed directions. If "Horizontal" is selected on the toolbar, all zooming in, zooming out, and panning can only be done in the horizontal direction. Similarly, if you select "Vertical", all operations will only be performed in the vertical direction.
5. Mark recording points. Right-click the mouse in the curve area, and a menu will pop up. Click "Mark Recording Points" to turn off or enable the mark recording point function. When marking recording points is on, all recording points will be marked with thick dots.
6. Curve display options. Right-click the mouse in the curve area, and a menu will pop up. Click "Curve Settings", and the user can set the color, font, line thickness, and Y-axis unit of the curve display area.
Step 6: File export
The user clicks the menu "File->Export" to save the currently opened document or the current curve display area (if the current display area is stored, the file type should select the option with the word for Window) as txt, csv, xls, jpg, bmp and other data formats.
Step 7: Print
1. Before printing, the user should determine what will be printed. Please click the menu "File->Print and Output Options", and in this dialog box, select the content or area to be printed.
2. Click "File->Print" to complete document printing.
YUWEN GGL-10 Industrial-grade economical temperature recorderSpecifications
LIST | VALUE |
---|---|
Temperature measurement range | -35~80℃ |
Temperature accuracy | ±0.3℃ |
Temperature resolution | 0.1℃/0.2℉ |
Sensors location | built-in |
Sampling rate | Optional 2s~ 24h |
Data storage | 64KBytes (32,000 readings in total) |
Interface | USB |
unit conversion | ℃/℉ |
Power | User-replaceable 3V lithium battery |
Dimensions | 120*37*23mm |
supporting software | DGraph, USB driver (included in the companion CD) |
Battery life | 1 year |
host material | ABS |
YUWEN GGL-10 Industrial-grade economical temperature recorder Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.