The main purpose of measuring the viscosity of a paste is to understand its rheological properties in order to optimize its preparation and application.
The specific reasons are as follows:
Ensure product quality: Paste is a semi-solid substance whose quality and stability are greatly affected by its viscosity. By measuring the viscosity of the paste, its composition ratio and preparation process can be adjusted to ensure the quality and stability of the product.
Improve product performance: The performance of the paste is greatly affected by its viscosity. By measuring the viscosity of the paste, the best application conditions can be determined, thereby improving the performance and application effect of the product.
Optimizing the production process: The measurement of paste viscosity can be used to optimize the production process, thereby improving production efficiency and reducing production costs.
Promote technology development: Paste viscosity measurement technology is an important physical testing technology, and its development can promote technological progress and product innovation in related fields.
In summary, measuring the viscosity of paste has important application value, which can optimize product quality, product performance and production process, and promote technological development and product innovation in related fields.

Rotational viscometers are widely used in paste viscosity testing, which can help manufacturers control the viscosity and fluidity of pastes to ensure product quality and stability.
The following are the basic steps of Rotational Viscometer in the detection of paste viscosity:
Sample preparation: Stir the paste sample to be tested evenly and bring it to the required temperature.
Instrument preparation: turn on the Rotational Viscometer, adjust the temperature and rotation speed, and calibrate the zero point.
Sample test: inject the sample into the viscometer, pay attention to avoid the generation of air bubbles, record the reading, and record the time and temperature. Repeat the test three times and take the average value.
Data processing: Calculate the viscosity value of the sample according to the readings obtained from the experiment, and perform data analysis.
NBCHAO reminds you: When testing the viscosity of the paste, you should pay attention to the temperature and stirring time of the sample to ensure the uniformity and stability of the sample. In addition, different types of pastes, such as cosmetics, medicines, etc., may have different measurement conditions and data processing methods, which need to be adjusted according to the actual situation. At the same time, when using a Rotational Viscometer for paste testing, attention should also be paid to the maintenance and maintenance of the instrument to ensure the accuracy and stability of the test results.