Surfix®Pro series dry Film Thickness Gauge is a dry Film Thickness Gauge with professional features from PHYNIX. This article lists the comparison of its Surfix®Pro series dry Film Thickness Gauge. It can be seen that compared with the naming methods of domestic Thickness Gauge manufacturers, foreign countries will be more standardized. Whether it is the American Defelsko (Difelsko) or PHYNIX (Phoenix), its F and N logos are recognizable. You can understand it. The main difference between PRO series Thickness Gauges lies in the measurement principle and measurement range, and from the perspective of hardware, it is mainly reflected in the difference in the probe.
| Compare category | Surfix® Pro FN0.2 | Surfix® Pro F 1.5R | Surfix® Pro F 20 | Surfix® Pro F 3.5 | Surfix® Pro FN 1.5R | Surfix® Pro F 10 | Surfix® Pro FN 3.5 | Surfix® Pro FN 1.5/90° |
| product picture | ![]() | |||||||
| brand | Phoenix | |||||||
| place of origin | Germany | Germany | Germany | Germany | Germany | Germany | Germany | Germany |
| Specification comparison | ||||||||
| Measuring principle | Electromagnetic induction + eddy current | Electromagnetic induction | Electromagnetic induction | Electromagnetic induction | Electromagnetic induction + eddy current | Electromagnetic induction | Electromagnetic induction + eddy current | Electromagnetic induction + eddy current |
| Measuring range | 0~200μm | 0~1500µm | 0~20000μm | 0~3500µm | 0~1500µm | 0~10000μm | 0~3500µm (F); 0~3000µm (N) | 0~1500µm |
| tolerance scope | ±2.5% | +/– 3μm or 3% | +/– 5μm or 3% | +/– 3μm or 3% | +/– 10μm or 3% | +/– 5μm or 3% | ||
| resolution | 0.1μm | |||||||
| probe | FN0.2 standard external probe: Ø14x 83mm Zero calibration accuracy +/– (0.7μm+1.5 %) Aluminum foil calibration accuracy +/– (0.7μm+1,0 %) | F 1.5R special external probe Ø14x14x14mm Zero calibration accuracy +/– (1.0 μm + 2 %) Aluminum foil calibration accuracy +/– (1.0 μm + 1 %) | F 20 special external probe Ø50x 57mm Zero calibration accuracy +/– (10 μm + 4 %) Aluminum foil calibration accuracy +/– (10 μm + 2 %) | F 3.5 special external probe Ø14x83mm Zero calibration accuracy +/– (2.0 μm + 2 %) Aluminum foil calibration accuracy +/– (2.0 μm + 1 %) | N1.5 standard external probe Ø14x 24 x 24mm Zero calibration accuracy +/– (1.0 μm + 2 %) Aluminum foil calibration accuracy +/– (1.0 μm + 1 %) | F 10 special external probe Ø25x 47mm Zero calibration accuracy +/– (5.0 μm + 2 %) Aluminum foil calibration accuracy +/– (3.0 μm + 1 %) | FN 3.5 special external probe: Ø 25x 47mm Zero calibration accuracy +/– (2.0 μm + 2 %) Aluminum foil calibration accuracy +/– (2.0 μm + 1 %) | FN 1.5/90° special external probe: Ø 8x 11 x 170mm Zero calibration accuracy +/– (1.0 μm + 2 %) Aluminum foil calibration accuracy +/– (1.0 μm + 1 %) |
| Statistical function | n, x ¯ , s, Min, Max, Kvar, cp, cpk | n, x ¯ , s, Min, Max, Kvar, cp, cpk | n, x ¯ , s, Min, Max, Kvar, cp, cpk | n, x ¯ , s, Min, Max, Kvar, cp, cpk | n, x ¯ , s, Min, Max, Kvar, cp, cpk | n, x ¯ , s, Min, Max, Kvar, cp, cpk | n, x ¯ , s, Min, Max, Kvar, cp, cpk | n, x ¯ , s, Min, Max, Kvar, cp, cpk |
| Icon function | have | have | have | none | have | have | have | have |
| Weight (g) | 205+70g | 205+90g | 205+200g | 205+105g | 205+90g | 205+85g | 205+105g | 205+90g |
| Dimensions (mm) | 137×66×23 | 137×66×23 | 137×66×23 | 137×66×23 | 137×66×23 | 137×66×23 | 137×66×23 | 137×66×23 |
| Power supply form | 2 AAA batteries | |||||||
| fulfill the standard | DIN, ISO, BS ASTM | |||||||
| Calibration certificate | factory certificate | |||||||
| system language | multilingual menu | |||||||
| display screen | High resolution color display backlight | |||||||
| Data interface | Bluetooth 4 and USB 2 ports | |||||||
| supporting software | phynix.connect data transfer software | |||||||
| Friendly reminder: This page is a comparison table of Surfix® Pro series dry Film Thickness Gauges, please read the official information in detail. | ||||||||