Aiming at the development of boron-containing ultra-thin fireproof coatings for steel structures, this paper mainly introduces that based on the basic formula of boron fireproof coatings, the general range of five kinds of fireproof additives such as zinc borate is determined by single factor choice test. A good formula for boron-containing ultra-thin steel structure fireproof coatings has been obtained through cross-testing. From the analysis of the test results, when the coating thickness is 1.1 mm, the fire resistance limit can reach 76 min 57 s, exceeding the requirement in GB 14097-2002 by about 17 min.
Development and analysis of fire-proof coatings for boron-containing ultra-thin steel structures
Guess you like it
Relevant knowledge
- 1Principle and application of muffle furnace
- 2Introduction of working principle and application of muffle furnace
- 3Working principle and application analysis of muffle furnace
- 4Application of muffle furnace in Determination of Tobacco Ash
- 5Nondestructive measurement of dry coating thickness
- 6Coated steel coatings - Determination of dry-film thickness
- 7Application scheme of coating thickness test on wood board [with test video]
- 8Curved plastic coating thickness test application scheme [with test video]
- 9PosiTector200C ultrasonic coating Thickness Gauge on concrete coating thickness measurement application
Author:
赵敏; 孙均利
Source:
含硼超薄型钢结构防火涂料的研制
Products