Instructions for the use of MOLSUN-105A pure water machine

Function Description

1.1 Working mode selection

After shorting the K2 of the circuit board, the system works in the pressure control mode, and the digital display pressure value (in kilograms).

After K2 is disconnected from the circuit board, the system works in the fixed time water intake mode, and the digital display time (unit S).

1.2 Settings

When setting the state, the following keys are multiplexed.

during normal work

function at setup

illustrate

Tertiary key

set up

When in standby, press and hold for 3 seconds to enter the settings

RO flush key

choose

In pressure control mode, choose to set high-low pressure control points.

Select the hundreds, tens and ones to be modified in the fixed time water intake mode

cycle key

Increase

increase the number

primary key

reduce

reduce the number

When the system is in the standby state, press and hold the setting button for 3 seconds to enter the setting state, press the selection button to select the data item to be modified, and press the increase or decrease to modify the data. You can press the standby button or press the setup button again to exit the setup.

2 Indicator light description

indicator light

state

illustrate

start light

red

standby

green

work, set

Call the police

1 second - 1 second flashing

Low water inlet pressure or faulty water inlet pressure switch

0.5 seconds - 0.5 seconds flashing

Medium or high level switch failure

0.3 seconds - 0.3 seconds flashing

Water level below low level or low level switch failure

primary water intake

flashing

First-level water intake at a fixed time and the window displays the remaining time for the first-level water intake

always on

Level 1 random water intake, or Level 1 and Level 3 are taking water at a fixed time at the same time but the window display is in the period when the remaining time of Level 3 water intake is displayed.

Three-stage water intake

flashing

Three-level fixed time water intake and the window displays the remaining time for three-level water intake

always on

Level 3 random water intake, or Level 1 and Level 3 are simultaneously taking water at a fixed time but the window displays the remaining time of level 1 water intake.

rinse

flashing

It is in programmed automatic flushing such as power-on flushing, regular flushing or flushing after water creation.

always on

RO manual flushing

cycle

flashing

Timed automatic cycle

always on

artificial circulation

pure water backup

flashing

The water level in the Water Tank is between the medium level and the high level

always on

Water tank level reaches high level

off

The water level of the Water Tank is lower than the medium level

make water

Bright

Hydrogenation state

3 rinse

1) RO automatic flushing: When automatic flushing is performed, the flushing indicator flashes to indicate

2) RO manual flushing: When the RO button is pressed, the manual flushing is performed, and the RO button is pressed again to interrupt the RO manual flushing, otherwise the flushing will end automatically after 5 minutes. When performing RO manual flushing, the flushing indicator is always on.

4 Make water

When the system detects the low pressure value set by the pressure tank, it will start water production, and when it reaches the high pressure value set by the pressure tank, it will stop water production.

5 transport water

This system adopts the pressure control mode. The delivery pump automatically executes the water delivery mode, and sends the pure water from the aging machine interface at the back of the machine to the pure water for the relevant aging machine, and is controlled by the high limit of the back-end pressure to stop.

6 Alarm and protection

6.1  当系统检测到进水压力低或自来水停水时或滤芯及膜被堵时,不能执行或中断执行的造水动作,系统发出1s-1s间隔的声光报警。按任意键或一分钟后自动消除报警声音。此时应停机检查自来水(是否停水或处于低压),检查滤芯或RO膜是否被堵。

系统维护与耗材更换:

     1)、耗材大致更换周期、更换方法 (请用户对应工艺流程图)

对应的

耗材名称

大约更

换周期

更换判定

更换方法

一级预处理滤芯

(粗滤芯)

1-3个月

通过透明滤瓶观察滤芯顔色变成深黄色即可更换

用随机配送的皮带板手,按逆时针旋开,取出耗品, (请注意筒体内的黑色橡胶圈不要弄丢了!)。

然后装上新的滤芯,滤芯没有正反方向。滤芯的中心孔要与筒体的中心孔对齐,然后把筒体装到固定的端盖接口上,用皮带扳手套住筒体,顺时针旋转拧紧。

二级预处理滤芯

(活性碳滤芯)

6个月


反渗透膜(含膜壳)

1-2年


取下旧膜壳(膜在膜壳里),换上新的膜壳(新膜在膜壳里)即可。 注意:膜壳有三个不同接口(进水、纯水、浓水),更换时请仔细观查,更好贴上相应标签,以防接口接错。

纯化柱mp4

According to用水量不同寿命不同

设备输送至QSUN时,会显示电阻值,当电阻小于5 MΩ.cm,则需要更换

此柱有两个接口,无正反方向。很方便更换。

2) 故障现象诊断和处理

常见故障

原  因  分  析

解  决  方  法

开机出现系统保护,设备报警

① 进水阀门未打开

② 自来水压力低于0.1Mpa

③ 滤芯被堵

④ 进水电磁阀没有全打开

① 打开进水阀门

② 调整自来水压力

③ 更换新的滤芯

④ 更换对应型号的新进水电磁阀

按下取水键后,取水指示灯亮,不能正常取水

① 取水电磁阀坏

② 智能控制器坏

① 更换新的电磁阀

② 更换新的智能控制器

插上电源插头,面板指示灯不闪烁,不能开机

① 插座没电

② 保险管熔断

③ 智能控制器上的灰色连接线松脱

④ 开关电源有220V输入无24V或48V输出

① 更换到有电插座

② 更换保险管

③ 重新连接好灰色连接线

④ 更换对应型号新开关电源

产水量降低

① 预处理滤芯堵塞

② RO膜堵塞

③ 天气温度低于10℃

① 更换预处理滤芯

② Replace the RO membrane

③ After the temperature rises, the water production will naturally increase

The quality of effluent water is reduced

① Expired consumables

② The probe of the resistance meter or conductivity meter is broken

① Replace consumables

② Replace the corresponding probe

The machine does not make water

① The pipeline is wrongly connected

② The machine will not start without power

③ Expiration of consumables

④ The booster pump does not work

⑤ The intelligent controller is broken

⑥ The water inlet solenoid valve is broken

① Connect the pipeline correctly

② Replace circuit accessories

③ Replace consumables

④ Replace the booster pump

⑤ Replace the smart controller

⑥ Replace the solenoid valve