A little note of the international standard illuminant lighting booth

As the name suggests, the color comparison light box is used to build an environmental light box for color comparison and color comparison, which is very suitable for those industries that have very high requirements for product color consistency. In fact, these industries are very broad: the car is not it? Is it ceramic? What about cosmetics? Even furniture, paint, leather and more. You will also often buy the experience that the color difference from Taobao is completely different from the picture, which is the function of the color comparison light box.


Colorimetric light boxes are generally equipped with push-button switches and electronic rectifiers to control the light source. These components ensure consistent viewing conditions for users when comparing colors. The general colorimetric light boxes have passed the calibration error approval of a certain standard. The outside of the color comparison light box looks like a rectangular grid, and the inside is usually painted gray. The author only has a copy of Sheen's color comparison light box information. You may wish to take a look:

A little note with picture 1 of the international standard light source colorimetric light box

"British SHEEN Company International Standard Light Source Colorimetric Light Box Specifications and Brief Operation"


one. This light box is suitable for those industries that need to maintain color consistency and color quality, such as: automotive, ceramics, cosmetics, dyes, food, footwear, furniture, inks, knitwear, leather, eyepieces, packaging, printing and textile industries wait.

two. The CAC colorimetric light box series are equipped with touch-key switches and electronic ballasts to control the light source. These components ensure excellent consistency in viewing conditions and also allow you to use both 26mm and 38mm lights. All SHEEN colorimetric light boxes are approved by EN55015 for calibration tolerance.


three. The interior of the colorimetric light box is painted gray (ref. 14.40D), but if you prefer other grays (such as: Munsell gray N5), we can also meet your requirements as long as it is specified on the order.


Four. Other options:

We stock diffusers for CAC60, 120 and 150 light boxes, but should only be used when evaluating materials with high emissivity (add '/D' to order if required).


five. Electrical Notes:

All light boxes are equipped with light tubes and need to be grounded. Our electronic ballasts are suitable for 220v or 240v (50-60Hz). If other voltage requirements are required, please be sure to specify on the order. The light box has a "use time Recorder", and the light of the light box should be replaced every 2000 hours. The "time Recorder" will automatically reset to zero after recording 10,000 hours.


six. A brief description of the conditions of use:

In order to obtain good test results, external dazzling glare and all things/environments that can cause visual disturbance should be avoided. The windows next to the color evaluation box should be fitted with gray curtains. There should be no direct light in the field of view, and the general light around should be "artificial daylight" like 200-300 kinks. The wall behind the light box should be painted light gray with light gray BS00A01 emulsion paint. These measures allow you to make accurate color evaluations in a comfortable working environment.


01
Power (on/off)
D65"Artificial daylight" fluorescent lamps, which comply with the D6500 international standard illuminant, and whose tolerances do not exceed the range specified in the first part of BS950.
D652Another level of "artificial daylight" fluorescent lamps (for those colors with low reflectance)
TL83Philips triphosphorous fluorescent lamps are often chosen as "display light sources".
TL84Philips triphosphorous fluorescent lamps are often chosen as "display light sources".
fTungsten lighting, which is required by the first part of BS950 for conditional colorimetric tests.
UVUV backlight to demonstrate the presence of fluorescent dyes and optical brighteners.

Other fluorescent lamps can be installed if desired, but for CAC150, CAC120 and CAC60, only a maximum of three fluorescent lamps and one tungsten lamp can be installed