What are the requirements for the installation location and use of the Biochemical Incubator?

Guide: When the buyer receives the biochemical Incubator, the first three questions we consider are how to move it? How to install? how to use? This article makes a summary of these three issues, so that you can use the biochemical Incubator without worry.

What are the requirements for the installation location and use of the biochemical Incubator?  Picture 1

Requirements for the installation location of the biochemical Incubator
1. The biochemical Incubator should be placed in a place with little dust and small temperature changes. The box must be grounded, use a three-pin plug, and the socket should be properly grounded.
2. Before opening the biochemical Incubator, you should fully familiarize yourself with the instruction manual and master the correct method of use. To maintain the service life of the biochemical Incubator.
3. It is strictly forbidden to contain volatile chemical solvents, explosive gases and flammable gases in the box; do not use flammable sprays near the biochemical Incubator to avoid ignition by electric sparks.
4. When working, avoid opening the door frequently to keep the temperature stable and prevent dust and dirt from entering.
5. After the cultivation is over, please pay attention to cut off the power in time, and take out the items and dispose of them properly in time.
6. In order to ensure the effective heat dissipation of the condenser, the distance between the condenser and the wall should be greater than 100mm. There should be 50mm of clearance on the sides of the cabinet and at least 300mm of clearance on the top of the cabinet.
7. The inside and outside of the biochemical Incubator should be kept clean every day, and should be cleaned after each use. If it is not used for a long time, it should be covered with a plastic dust cover and placed in a dry room. At the same time, the inner tank of the box wall and the surface of the equipment should be wiped frequently to keep it clean and increase the transparency of the glass. Do not wipe the outer surface with acid, alkali or other corrosive solutions.
8. Stop using the biochemical Incubator, turn off the main power button, and the power switch at the back of the equipment.
Biochemical Incubator handling requirements
1. Be careful when handling, the angle between the box and the horizontal plane should not be less than 60°.
2. When the operating temperature is low, there will be condensed water in the Incubator, and the accumulated water in the water tray should be cleaned regularly.
3. In order to maintain the appearance of the equipment, do not use acid or alkali and other corrosive substances to wipe the surface of the box body, and the inside of the box can be wiped dry regularly with a dry cloth.
4. When the Incubator is out of use, the power plug should be unplugged.
5. The minimum distance between the Incubator and the wall should be greater than 10cm to ensure good heat dissipation of the refrigeration system.
6. The room should be dry, well ventilated, and the relative humidity should be kept below 85%. There should be no corrosive substances, and avoid direct sunlight on the Incubator.
7. The power supply used must have a reliable ground wire to ensure reliable contact between the ground wire of the Incubator and the ground wire of the grid power supply to prevent damage caused by leakage or accidental grid power supply.
Requirements for the use of the biochemical Incubator
1. The biochemical Incubator should be installed as far as possible in a place with clean air and small temperature changes. A three-pin plug should be used, and the socket should be properly grounded.
2. Before opening the biochemical Incubator, you should be familiar with and understand the instructions of the supporting instruments and instruments of each component, and master the correct use methods.
3. It is strictly forbidden to contain volatile chemical solvents, explosive gases and flammable gases in the box; do not use flammable sprays near the Incubator to avoid ignition by electric sparks.
4. Always pay attention to whether there is any air leakage in the air circuit. 5. The biochemical Incubator has a breakpoint protection function and a delay function of about one and a half minutes. After the compressor
stops, it takes about one and a half minutes to restart.
Should be greater than 100mm. There should be 50mm of clearance on the sides of the cabinet and at least 300mm of clearance on the top of the cabinet.
7. The biochemical Incubator should avoid collision, shaking and vibration during transportation, repair and maintenance; the maximum inclination is less than 45 degrees.
8. Stop using it, turn off the main power button, and the power switch at the rear of the equipment. Avoid frequent door openings to keep the temperature stable while preventing the entry of dust and dirt.
9. The inside and outside of the box should be kept clean every day, and should be cleaned after each use. If it is not used for a long time, it should be covered with a plastic dust cover and placed in a dry room. At the same time, the inner tank of the box wall and the surface of the equipment should be wiped frequently to keep it clean and increase the transparency of the glass. Do not wipe the outer surface with acid, alkali or other corrosive solutions.
10. After the cultivation is over, turn the power switch to "0". If you don't take out the items immediately, please don't open the door.