YT-1200H 4 in 1 Gas Detector Operation Manual

Precautions:

Improper operation or unsuitable use environment may impair the performance of the instrument. In order to use the instrument safely and effectively , please carefully read the following correct operation procedures and safe use environment.

In order to ensure the safety and correct use of the instrument, the calibration and maintenance of the instrument can only be carried out by qualified professionals.

Opening operations, replacing batteries, and repairing parts can only be carried out in uncharged, safe places.

Calibration checks should be carried out regularly, and the calibration cycle should not exceed one year. Sensors that exceed the effective service life and have faults should be replaced in time.

It is strictly forbidden to shock the sensor with gas exceeding the measurement range.

The sensor window and water filter membrane need to be kept clean, if the sensor window is clogged or the water filter membrane is contaminated, it may cause the reading to be lower than actual gas concentration.

It is strictly forbidden to expose the instrument to an environment with high concentration of corrosive gas or oily gas to prevent damage to the sensor.

It is strictly forbidden to use the instrument in a high temperature and high humidity environment.

Users are not allowed to turn on the machine to repair or replace parts without authorization.

It is not allowed to replace the components or structures that affect the explosion-proof performance at will, so as not to affect the explosion-proof performance.

Potential electrostatic charge hazard, the instrument should avoid ignition hazard caused by electrostatic charge during normal use, maintenance and cleaning.

When used in an explosive environment, the device should not be touched or wiped. If it is necessary to wipe or touch it, it should be done in a safe place and used

Wipe the case with a wrung damp cloth, never wipe the case with a dry cloth!

Replace the battery with the same type of battery and do it in a safe place.

For portable products, before entering the dangerous area, the human body is professionally discharged with static electricity, and then carries the instrument into the scene.

Charging needs to be carried out in a safe place, and use the special charger equipped with the main unit.

It is strictly forbidden to disassemble, charge or replace the battery in dangerous places.

Yuante YT-1200H 4-in-1 Gas Detector Operation Manual with Figure 1

Yuante YT-1200H 4-in-1 Gas Detector Operation Manual with Figure 2

Yuante YT-1200H 4-in-1 Gas Detector Operation Manual with Figure 3

National standards complied with in product development, design and production:

GB3836.1-2010 Explosive atmospheres Part 1: General requirements for equipment

GB3836.1-2010 Explosive atmospheres Part 4: Equipment protected by intrinsic safety type "i"

JJG693-2011 Verification regulations for combustible gas detection and alarm

GB15322.3-2003 Part 3: Portable combustible Gas Detectors with a measuring range of (0-100)%LEL

JJG365-2008 Verification Regulations for Oxygen Gas Detection and Alarm Instruments

JJG695-2003 Verification Regulations for Hydrogen Sulfide Gas Detection and Alarm Instruments

JJG915-2008 Verification Regulations for Carbon Monoxide Gas Detection and Alarm Instruments 

product description

此系列气体检测仪,是一种可灵活配置单种气体或多种气体传感器的便携式气体检测报警仪;最多可配备四个传感器,同时检测四种气体浓度;具有高清晰液晶点阵显示大屏,中英文操作界面, 声、光、振动三级声光报警提示,仪器自带报警记录功能,可存储 1 万条报警记录。无论是仪器所使用的传感器还是电路芯片,每一颗都来自原装进口很好品牌,从选型、到测试、到成品,都经过了严格的审核工序,仪器具有响应速度快、测量精度高、稳定性和重复性好等优点,整机性能居国内专业水平。仪器外壳采用高强度工程材质,其具有匠心的外形设计和令人炫目的色彩搭配定能重新定义气体浓度检测方式。

  仪器特点

采用世界良好进口高精度传感器

可同时检测任意四种气体

液晶点阵显示技术,支持中英文显示界面

气体浓度单位 PPM,mg/m3 可一键切换显示

可一键查看电池电压,及电池电量百分比

一键恢复出厂设置功能,可免去误操作的困扰

超高蜂鸣报警音,声、光、振动三重报警

带 1 万条报警记录功能,可在仪器上查看报警历史记录

大容量锂聚合物充电电池,可保证仪器长时间连续工作

主机采用高强度特殊工程塑料加柔软外包胶,坚固耐用,手感舒适,可防静电

技术性能

采样方式:扩散式

气体种类:氧气,可燃气体,一氧化碳,硫化氢 (以常规四气为例,其他气体也可选)

测量范围:0-30%VOL、0-100%LEL、0-1000PPM、0-100PPM (以常规四气为例)

分 辨 率:0.01%VOL、1%LEL、1PPM、0.1PPM (以常规四气为例)

检测误差:≤±3%F.S.

浓度单位:ppm、mg/m3 可一键切换显示,浓度值由系统自动换算

显示技术:单色点阵 128*128 LCD 图形显示

背光:可手动设置背光时间,报警时自动开启背光

数据记录:超 10 万组存储数据,存储间隔 10-3600 秒可调(选配功能)

报警记录:存储 10000 条报警记录,可在仪器上直接查看

电 池:3.7V 可充电锂电池,电池容量 2300mA

工作时间:10-12 小时连续;有毒气体 200 小时

充 电 器:带 USB 接口的旅行充电器,充电时间 4-6 小时

防爆等级:ExiaⅡCT3

防护等级:IP65

工作温度:-20℃~50℃

工作湿度:0-90%RH (无冷凝)

壳体材料:ABS+皮套

外型尺寸:131*83*35 (长*宽*厚)

整机重量:240 克(主机+皮套)

操作说明

  操作按键的功能描述

Yuante YT-1200H 4-in-1 Gas Detector Operation Manual with Figure 4


注: 1、长按键功能限于检测界面,菜单界面及设置模式无长按键功能;

2、在检测界面中同时 长按 “ 上” 键和“ 下”  键 3  秒以上,可实现“ 一键归零” 功能。


快捷功能说明

1、 快速 归零:将仪器置于纯净的空气中,在检测界面时,同时长按“上”和“下”键 3 秒钟以上,仪器将各通道数据自动归零(氧气则为 20.9%,氮气为79.1%,二氧化碳则为400ppm),在非纯净的空气中时,请不要进行此项操作;

2、 单位转换:在检测界面时,长按“下”键 3 秒钟以上,仪器自动将显示的数据进行单位转换,此功能限于“ppm”与“mg/m3”之间互相转换,其它单位无转换功能。

3、 界面转换:在检测界面时,短按“电源”键 一下,仪器将切换显示至电量时间界面(显示时间及电池参数),反之亦可。

开启仪器

关机状态下长按“电源”键 3 秒钟以上,液晶背光亮,指示灯亮,蜂鸣器“哔”一声,检测仪显示“仪器开启”0.5秒,然后显示公司名称 1 秒,再后显示产品型号、产品名称及通道信息 2 秒,再后显示“预热等待”进行传感器预热倒计时,倒计时完成后显示“启动完毕”0.5 秒,即完成仪器启动过程。

Yuante YT-1200H 4-in-1 Gas Detector Operation Manual with Figure 5

检测 界面

当仪器启动完成后,仪器进入检测界面,如下:

非中文四气时,界面右上角分别为时间“12:30”及电池电量符号“Yuante YT-1200H 4-in-1 Gas Detector Operation Manual with Figure 6 ”;

以下从左至右依次 1 至 4 气的检测界面,以 4 气界面为例,中间 4 格中,左上为 1 通道,右上为 2 通道,左下为 3 通道,右下为 4 通道;在每个通道数据中, “CO”或“一氧化碳”为气体类型的分子式或中文名称,“ppm”为气体浓度单位,数字为气体浓度数据;

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 7

电量时间界面

在检测界面时,短按一下“电源”键,即可切换显示至电量及时间显示界面,此界面中,再按一次“电源”键,可返回到检测界面,界面显示如下:

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 8

关闭仪器

正常测量状态下长按“电源”键 3 秒钟以上,蜂鸣器鸣叫,液晶显示“仪器关闭”0.5 秒后,LCD 关闭,背光关闭,检测仪进入休眠状态。

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 9

报警状态

当仪器检测到任意气体浓度超过设置的低报警值时,仪器即启动低报警,超过报警值浓度数据自动反白显示,同时蜂鸣器连续“哔-哔”响,蓝色指示灯闪烁,频率为 2HZ;

当仪器检测到任意气体浓度超过设置的高报警值时,仪器即启动高报警,超过报警值浓度数据自动反白显示,同时蜂鸣器连续“哔-哔”响,红色指示灯闪烁,频率为 4HZ;如果仪器同时检测到低报警及高报警,将优先执行高报警动作。

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 10

电量不足

在开机状态下,检测仪检测到电池电量过低时,非中文四气时主界面的右上角,或者在电量时间界面中电池符号显示为空格 ,仪器将会激发声、光低电量报警,仪器每隔 5 秒蜂鸣器“哔”一声,指示灯闪一下,以提示操作者电池电量不足需要充电。当电量耗尽时仪器将强制自动关机, LCD 显示 “电池电量低”0.5 秒,之后显示“仪器关闭”0.5 秒,检测仪进入休眠状态。

当发生低电量报警后,操作者应给检测仪关机充电,充电时间大约 4-6 小时。

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 11

菜单操作

仪器除了快捷功能外,其它所的有功能均需要进入菜单操作,在检测界面长按“上”键三秒以上,仪器将立即进入主菜单界面;在主菜单界面中用“上”键或“下”键选择“退出菜单”选项时,按一下“电源”键即可返回到检测界面;

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 12

菜单树及功能

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 13

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 14

报警值设置

在主菜单界面中,用“上”键上翻或“下”键下翻选择 “报警值”选项,再按一下“电源”键,即可进入“报警值”子菜单;

在该子菜单界面中,使用“上”键或“下”键可以上下选择预修改的选项;在选择 “退出”选项时,再按一下“电源”键即可返回到主菜单界面;

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 15

“报警设置”子菜单共有 3 个选项(不算退出选项),第 1 个选项为“通道选择”,选择想要修改的通道, 在修

改下面两个选项前均需要提前设置这个选项;

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 16

第 2 项和第 3 项分别为“低报”和“高报”,可以分别设置当前通道气体的高、低报警值;先选中预修改的选项,按一下“电源”键确认即可进入设置模式,在设置模式中,使用“上”键增上数值,“下”键下少数值,“电源”移动光标位置,光标移动到最高位后,再按一下“电源”键,仪器长“哔”一声,指示齐亮,之后退出设置模式,即完成修改;

下面以修改第二通道的低报值为例,高报值设置可参考此过程。

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 17

报警模式设置

在主菜单界面中,用“上”键上翻或“下”键下翻选择 “报警模式”选项,再按一下“电源”键,即可进入“报警模式”子菜单;

在该子菜单界面中,使用“上”键或“下”键可以上下选择预修改的选项;在选择 “退出”选项时,再按一下“电源”键即可返回到主菜单界面;

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 18

“报警模式”子菜单中共有 3 个选项(不算退出选项),分别为“声音”、“灯光”以及“振动”,“声音-开”表示开启蜂鸣器功能,“声音-关”表示关闭此功能;“灯光-开”表示开启指示灯报警功能,“灯光-关”表示关闭此功能;“振动-开”表示开启振动报警功能,“振动-关”表示关闭此功能。

仪器设置

在主菜单界面中,用“上”键上翻或“下”键下翻选择“仪器设置”选项,再按一下“电源”键,即可进入“仪器设置”子菜单;

在该子菜单界面中,使用“上”键或“下”键可以上下选择预修改的选项;在选择 “退出”选项时,再按一下“电源”键即可返回到主菜单界面;

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 19

第 2 项为“灰度”设置,第 3 项为“背光”设置,“背光”设置是指在仪器无操作一定时间后仪器自动关掉显示背光,以节约电池电量,如果不想使用此功能,可以将此值设为 0 即可;设置过程略。

时钟设置


在主菜单界面中,用“上”键上翻或“下”键下翻选择“时钟设置”选项,再按一下“电源”键,即可进入“时钟设置”子菜单;

在该子菜单界面中,使用“上”键或“下”键可以上下选择修改时间或日期或者退出;在选择“退出”选项时,再按一下“电源”键即可返回到主菜单界面;

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 20


“时钟设置”子菜单只有“日期”及“时间”两个设置选项(不算退出选项);选中“日期”选项,确认后可以修改仪器的日期(格式为“年/月/日”);选中“时间”选项,确认后可以修改仪器的时间(格式为“时:分:秒”),但是“秒”不可修改;

下面以设置时间为例,设置日期可参考此过程。

Yuante YT-1200H 4-in-1 Gas Detector Operation Manual with Figure 21

仪器校准

在主菜单界面中,用“上”键上翻或“下”键下翻选择“仪器校准”选项,再按一下“电源”键,仪器将提示输入密码,输入正确的密码(假设为 0000),每按一次“电源”键,光标将向左移动一位,当光标位为最高位(按下 3 次“电源”键后)时,再按一下“电源”键后,仪器提示“输入密码正确”,即可进入“仪器校准”子菜单;如果输入的密码错误,仪器将显示“输入密码错误”,然后自动返回到主菜单界面。

在该子菜单界面中,使用“上”键或“下”键可以上下选择预操作的选项;在选择“退出”选项时,再按一下“电源”键即可返回到主菜单界面;

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 22

“仪器校准”子菜单共有 4 个选项(不算“退出”选项),第 1 个选项为“通道”,选择想要校准的通道, 在操作后面三个选项前均需要提前设置这个选项;过程请参考“报警值”子菜单下的第 1 项“通道”选择操作。

零点校准

第 2 项为“零点”选项,选定后可以校准当前通道的零点;选中此选项,按一下“电源”键,仪器将显示“零点校准”界面,LCD 上侧显示“请输入纯净空气或纯氮气体”(通道为氧气时则仅显示“请输入纯氮气体”),LCD 下

侧显示当前通道的气体类型、预校准值(默认为 0)、当前显示值(VA)、当前 ADC 值(AD)以及预操作项(默认为退出),即已进入待校准状态;

在待校准状态下,随时可以使用“上”键或“下”键将预操作项修改为“退出”,然后按一下“电源”键,返回到“仪器校准”子菜单。

在待校准状态下,待 LCD 下方两个数值稳定后,使用“上”键或“下”键将预操作项修改为“确认”,然后按一下“电源”键,仪器长“哔”一声,指示灯齐亮,即可完成校准操作;

在待校准状态下,待 LCD 下方两个数值稳定后,使用“上”键或“下”键将预操作项修改为“确认”,然后按一下“电源”键,仪器长“哔”一声,指示灯齐亮,即可完成校准操作;

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 23

注意:执行此选操作功能时,请先将仪器置于纯净的空气中 3-5 分钟,待仪器 LCD 下方的数值稳定后,方

可进行,否则会造成显示数据不准。

标气校准

第 3 项为“标气”选项,选定后可进入“标气”校准操作;选中此选项,按一下“电源”键,仪器将显示“标气校准”界面,LCD 上侧显示“请输入标准气体”(通道为氧气时则显示“请输入标准气体或纯净空气”);LCD 下侧显示当前通道的气体类型、预校准值(默认为满量程)、当前显示值(VA)、当前 ADC 值(AD)以及预操作项(默认为退出),即已进入待校准状态;

在待校准状态下,随时可以使用“上”键或“下”键将预操作项修改为“退出”,然后按一下“电源”键,返回到“仪器校准”子菜单。

在待校准状态下,使用“上”键或“下”键,将预操作项修改为“设置”,然后按一下“电源”键,进入数值修改状态,预校准值(气体类型右侧 4 位数据)最低位被选中,此每按一下“电源”键,光标(即被选中的位)向左移动一位,According to具体的标气浓度,使用“上”键或“下”键修改好预校准值,当光标移动到最高位时,再按一次“电源”键,退出数值修改状态,进入待校准状态;待 LCD 下方两个数值稳定后,使用“上”键或“下”键,将预操作项修改为“确认”,然后按一下“电源”键,仪器长“哔”一声,指示灯齐亮,即可完成校准操作;

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 24

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 25

标气校准过程如下:

首先按下图所示连接好气路;

然后进行仪器校准子菜单,选定“标气”选项,按确认后进入待校准状态,气体类型右则数值为标气校准点,仪器默认为满量程,需要According to现场实现的标准气体浓度进行修改,原则上所选的标准气休浓度应大于 50%满量程,小于 100%满量程;

修改好校准点后以 400mL/min 的流量释放标准气体到检测仪中,之后继续观察 LCD 下方显示的实时浓度值(VA)及 ADC 值(AD),待两个显示值基本稳定后(约 30-90 秒,不同气体传感器稳定时间有所差别),使用“上”键或“下”键,将预操作项修改为“确认”,然后按一下“电源”键,仪器长“哔”一声,指示灯齐亮,即可完成校准操作。

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 26

注 意:执行此选操作功能时,一定要先连接好标准气体的管路,待仪器 LCD 下方的数值稳定后,方可进行,否则会造成显示数据不准。

恢复出厂校准

第 4 项为“恢复”选项,选定后可进行“恢复”出厂校准操作;选中此选项,按一下“电源”键,仪器将显示“恢复出厂校准”界面,LCD 上侧显示通道值、通道气体以及文字“恢复出厂校准”;LCD 下侧显示“是”和“否”两个选项,仪器默认光标在“否”选项上;

如果不需要恢复成出厂校准状态,此时可以按一下“电源”键,退出到“仪器校准”子菜单界面;

如果需要恢复成出厂校准状态,此时可以使用“上”键或“下”键使光标移动到“是”选项上,然后按一下“电源”键,仪器长“哔”一声,指示灯齐亮,仪器自动退出到仪器校准子菜单界面,即已完成“恢复出厂校准”操作。

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 27

注意:由于传感器的输出特性,仪器使用时间越长,使用出厂校准可能就会导致测量越不准确,请谨慎使用此功能。

记录查看

在主菜单界面中,用“上”键上翻或“下”键下翻可选择“记录查看”选项,再按一下“电源”键,即可进入“记录查看”子菜单;

在该子菜单界面中,使用“上”键或“下”键可以上下选择预修改的选项;在选择 “退出”选项时,再按一下“电源”键即可返回到主菜单界面;

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 28

“数据记录”子菜单共有 4 个选项(不算退出选项),第 1 项为“时间设置”,可设置仪器的保存间隔时间,仪器最低记录周期为 10 秒,往上以 10 秒为一等级,最大可达 1 个小时间;设置过程略。

第 2 项为“历史记录”,选中该选项,按一下“电源”键确认后即可进入“历史记录”查看界面,LCD 上方显示记录编号及预操作选项(默认为退出),LCD 下方显示相应记录的日期、时间以及各通道记录信息。

在历史记录查看界面中,使用“上”键或“下”键将预操作项修改为“退出”,然后按一下“电源”键,即可返回到“记录查看”子菜单界面。

在历史记录查看界面中,可以修改记录编号,从而查看对应编号的记录信息,仪器自带大容量的存储芯片,

最多可同时保存 10 万条记录;使用“上”键或“下”键将预操作项修改为“设置”,然后按一下“电源”键,进入编号修改状态,记录编号的最低位被选中,此每按一下“电源”键,光标(即被选中的位)向左移动一位,此时使用“上”键或“下”键可修改记录编号被选中位的数值,同时 LCD 下方的记录信息实时更新,当光标移动到最高位时,再按一次“电源”键,退出编号修改状态。

Yuante YT-1200H 4-in-1 Gas Detector Operating Instructions with Figure 29

第 3 项为“报警记录”选项,按一下“电源”键确认后即可进入“报警记录”查看界面,逐个查看每条浓度记录,仪器自带大容量的存储芯片,最多可同时保存 3000 条记录;在报警记录查看界面中,可以修改记录编号,从而查看对应编号的记录,操作过程同“历史记录”。

注意:如果存储芯片存满后(无论是“历史记录”还是“报警记录”),用户没有删除记录,仪器将自动从最前开始存起,逐一覆盖前面的记录,如有重要记录,请一定要在记录存满前先行导出备份。

第 4 项为“删除”选项,该选项可以实现对仪器内部存储数据(包括历史记录及报警含记录)的删除,具体步骤为先选中该选项,按一下“电源”键确认后,仪器将显示“记录删除”界面,LCD 上侧显示文字“删除所有记录”;

LCD 下侧显示“是”和“否”两个选项,仪器默认光标在“否”选项上;

如果不需要删除所有记录,此时可以按一下“电源”键,退出到“记录查看”子菜单界面;如果需要删除所有记录,此时可以使用“上”键或“下”键使光标移动到“是”选项上,然后按一下“电源”键,仪器长“哔”一声,指示灯齐亮,仪器自动退出到记录查看子菜单界面,即已完成“删除所有记录”操作。

元特YT-1200H四合一气体检测仪操作说明书配图30

  通道信息

在主菜单界面中,用“上”键上翻或“下”键下翻选择“信息查看”选项,再按一下“电源”键,即可进入“通道信息”子菜单;

在该子菜单界面中,使用“上”键或“下”键可以上下选择“通道”及“退出”两个选项;在选择“退出”选项时,再按一下“电源”键即可返回到主菜单界面;

在界面下方为当前选定通道实时浓度及实时 ADC值,只可查看,不能修改。

元特YT-1200H四合一气体检测仪操作说明书配图31

"Channel" is used to select the channel information to be displayed on the submenu interface. For the specific operation process, please refer to the first item "Channel" selection under the "Alarm Value" submenu.

Common faults and solutions

元特YT-1200H四合一气体检测仪操作说明书配图32

NBCHAO E-shop
Guess you like it
Relevant knowledge