Polyvinyl chloride film, also PVC film, is a film prepared by polyvinyl chloride resin and other modifiers through a preparation process. It is generally used for panel surface packaging, electrical adhesive tape, and shoes, toys, and raincoats in daily life. , tablecloths, etc., are widely used. PVC film is insoluble in water, alcohol, gasoline, and can swell or dissolve in ether, ketone, chlorinated aliphatic hydrocarbons and aromatic hydrocarbons. At room temperature, it is resistant to concentrated hydrochloric acid, 90% sulfuric acid, and 50%-60% nitric acid. And caustic soda solution below 20%.
This article is a routine experimental performance testing instrument scheme for PVC films, including coating film, roughness, adhesion, Thickness Gauge, color measurement, and gloss testing. details as follows:
| Mechanical Properties Testing Instruments - Destructive | |
![]() | Modern Environment QCJ Paint Film Impact Tester |
| Specification parameters: impact type spherical collision top impact, impact height 0~100cm, drop hammer mass 1000g, punch diameter Φ8mm, mold base aperture Φ15mm, meet the standard GB/T 1732-1993, overall size 252*140*1340mm, net weight of the instrument 14kg | |
| Film making and proofing equipment- Film making | |
![]() | Zhongyi Instrument TBJ-X1 Vacuum Adsorption Blade Coating Testing Machine |
| Specification parameters: coating accuracy ±0.003mm, coating thickness range 0.01~10mm, coating speed 2~180mm/s, coating format 300*400MM (coating length 0-400mm can be set arbitrarily), coating speed digital display , different speeds, vacuum adsorption size 300*400mm, vacuum aperture Φ1.2mm, hole spacing 20*20mm, scraper length, host power supply voltage 220V 50HZ, overall size 626*410*520 (length*width*height), weight and net weight 65KG, infinitely variable speed control, base plate material aluminum alloy | |
| Physical property testing instrument - thickness | |
![]() | Defelsko PosiTector 200 C1 Ultrasonic Coating Thickness Gauge |
| Specifications: Measuring principle ultrasonic, measuring range 50~3800μm, error range ±3%, application of concrete, glass fiber and other coatings, calibration certificate can be traced to NIST or PTB (long form), unit display μm/mils, average value of statistical function , standard deviation, maximum value, minimum value, no graphic function, data interface USB, data storage 250 readings, power supply alkaline battery or rechargeable battery, meet the standards ASTM D6132, ISO 2808, system language Chinese, English and other 16 kinds language optional | |
| Physical performance testing instrument - color | |
![]() | Color Spectrum CS-580A Spectrophotometer |
| Specifications:Illumination mode d/8 (scattered light source, 8-degree observation angle), SCS optical engine (spectral integration system), ETC (real-time calibration technology), equipped with SCI (including specular reflection component) / SCE (excluding specular reflection component) synchronous measurement Function. , sensor blue light enhanced array sensor, measurement light source A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL83, TL84 , NBF, U30, CWF, measuring time about 2s, measuring aperture Φ10mm, repeatable spectral reflectance: standard deviation within 0.08%; chromaticity value: within ΔE*ab 0.03 (after calibration, measure the whiteboard 30 times at intervals of 5s) Deviation), maximum: 0.05, operating language Chinese, English, data interface USB, Bluetooth (customizable), viewing angle CIE 2°/10°, lighting source CLEDs (full-band balanced Led light source), color difference formula ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*94, ΔE*00, data storage 20000 test data, battery life can be recharged, continuous measurement 10000 Secondary, 7.4V/6000mAh, display mode spectrogram/data, sample chromaticity value, color difference value/graph, pass/fail result, color bias, color simulation, display measurement area, historical data color simulation, manual input standard sample , Generate test reports, operating environment 0~45°C, relative humidity 80% or lower (at 35°C), no moisture condensation, storage environment -25°C to 55°C, relative humidity 80% or lower (at 35°C), no moisture condensation, external dimensions 181*73*112mm, instrument weight about 550g (excluding battery), integrating sphere size Φ40mm, Alvan total diffuse reflection surface coating, wavelength range 400~700nm, The wavelength interval is 10nm, the spectral half bandwidth is 5nm, the reflectance measurement range is 0~200%, the reflectivity resolution is 0.01%, the color space is CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy , reflectivity, the life of the lighting source is 5 years and 1.5 million times, and the difference between units ΔE*ab<0. | |
| Physical Property Testing Instrument - Gloss | |
![]() | Color Spectrum CS-380 Gloss Meter |
| Specification parameters: measuring angle 20°/60°/85°, measuring range 0~2000GU(20°); 0~1000GU(60°); 0~160GU(85°), repeatability 0~100GU: 0.2GU; 100 ~2000GU: 0.2%GU, measurement spot 10*10mm(20°); 9*15mm(60°); 5*38mm(85°), measurement mode average mode, standard sample and sample measurement, division value 0.1GU |1GU, meet the standards DIN 67530, ISO 2813, ASTM D 523, JIS Z8741, BS 3900 Part D5 and JJG696, data interface USB, Bluetooth (optional), data storage can store 100 standard samples, 10000 samples, operation Language Simplified Chinese, English, external dimensions 165*51*77mm, weight about 400g, power supply 3000mAh lithium battery, accuracy meets the requirements of JJG 696 first-class gloss meter, measurement time 1s, working temperature 0~40℃, relative humidity < 85%RH, non-condensing, suitable for paint, coating, ink, electroplating, plastic electronics, hardware, etc. | |
| Physical property testing instrument - roughness | |
![]() | Peric BC-110 Surface Roughness Meter |
| Specification parameters: display mode digital display, measurement parameters Ra, Rz, Rq, Rt, measurement range Ra, Rq: 0.05~10.0μm; Rz, Rt: 0.1~50μm, resolution 0.01, indication error ± (7-10) %, Indication value variability <12%, sampling length 0.25mm, 0.80mm, 2.50mm, evaluation length 1.25mm, 4.0mm, 5.0mm, stroke length 6mm, sensor-radius 10.0±2.5 μm, stylus static force ≤ 0.016N, sensor-measurement force≤0.5N, sensor-angle 90°, force change rate≤800N/m, power supply 3.7V lithium polymer battery, charger adopts DC 5V, 500mAh, charging time is about 3 hours, external dimensions 106*70*24mm, product weight 200g | |
| Mechanical Properties Testing Instruments - Adhesion | |
![]() | Modern Environment FZ-II Paint Film Adhesion Tester |
| Specification parameters: type manual, tracing diameter 0~10.5mm, rotating needle 808 brand stylus (used less than 5 times), working stroke ≥ 80mm, weight weight 100g, 500g, 200g, 200g, effective workbench area 100*50mm | |