Coating thickness testing on small parts is more difficult than testing other products with large contact surfaces. The contact surface of a conventional coating Thickness Gauge probe is more than ten millimeters, while small parts are often small in size, with a contact surface of only a few millimeters , and even two or three millimeters. In order to ensure the accuracy of the test, the basic requirement for coating thickness measurement is that the measured surface of the sample is larger than the contact surface of the probe, otherwise the test results will have large errors.
Therefore, generally for the coating thickness measurement of small parts, special small probes should be selected. At present, the coating Thickness Gauge brands at home and abroad can test the coating thickness of small parts, but relatively speaking, some imported brands do To a slightly higher technical level, such as EPK, Defelsko.
Below is a selection of coating Thickness Gauge models that can test the coating thickness of small parts in the northern and southern tides.
| Physical property testing instrument - thickness | |
![]() | Defelsko PosiPen Magnetic Pull-Off Coating Thickness Gauge |
| Specifications: Measuring principle magnetic induction, measuring range 5~500μm, error range ±10%, no statistical function, no power supply required, meets standards ASTM D7091/B499, ISO2808, etc., calibration certificate is available, measured surface temperature range -100℃~ 230℃, the unit shows μm/mils | |
![]() | Linshang LS225+N1500 Aluminum-Based Coating Thickness Gauge |
| Specification parameters: host display 240×160 dot matrix LCD, power supply mode 4 1.5VAAA alkaline batteries, working temperature 0°C~50°C, storage temperature -20°C~60°C, host size length 148mmX width 76mmX thickness 26mm, weight ( Including battery) 194g, measuring principle eddy current induction, base material non-ferromagnetic metal, measuring range 0~1500μm, resolution 0.1μm|1μm|0.01mm, repeatability≤±(0.8% reading+0.1μm) hand pressure test rack Test, measurement accuracy ± (2% reading + 0.3μm) five-point calibration, unit μm/mil, measurement interval 0.8s, minimum measurement surface Ø=7mm, minimum curvature convex surface 1.5mm, concave surface 10mm, minimum substrate thickness 0.05mm, User calibration supports zero point calibration, 1 point to 5 point calibration, probe size Φ15*110mm, probe weight 81g | |
![]() | Elcometer 211 A211F--1E Mechanical Coating Thickness Gauge |
| Specification parameters: Measuring principle mechanical, measuring range 0~40mils, minimum measuring surface Φ20mm, thinnest substrate 0.4mm, integrated probe, display screen scale display, overall size 200*60*30mm, minimum measuring surface Φ30mm, edge effect At least 6mm (0.24”) from the edge | |
![]() | Linshang LS225+F500 coating Thickness Gauge |
| Specification parameters: measurement principle magnetic induction, measurement range 0.0~500μm, error range ± (0.3μm+2%) five-point calibration, resolution 0.1μm: (0μm-99.9μm); 1μm: (100μm-500μm), the smallest measurement surface φ7mm, minimum curvature convex surface: 1.5mm; concave surface: 10mm, thinnest substrate 0.1mm, probe size Φ15*110mm, probe weight 81g, calibration mode supports zero point calibration, 1 point to 5 point calibration, statistical function maximum, minimum, Average value and variance value, power supply 4 1.5V AAA alkaline batteries, meet the standards GB/T 4956-2003, DIN EN ISO 2808, JJG-818-2005, system language Chinese, display screen 240x160 dot matrix LCD, working Temperature 0°C~50°C, machine weight 194g (including battery), machine size 148*76*26mm, base material ferromagnetic metal, repeatability≤±(0.1μm+0.8%) fixture test, measurement interval 1.5s, Storage temperature -20℃~60℃ | |
![]() | Defelsko PosiTector 6000 N90S3 Coating Thickness Gauge |
| Specification parameters: measurement principle eddy current, measurement range 0~625μm, error range ±3%, resolution 0.1μm, probe N90S3 probe (90°miniature), statistical function average value, maximum value, minimum value, number of tests, standard deviation , the functions shown in the picture are, power supply 3*AAA alkaline batteries, meet the standards ISO 2178/2360/2808, PrEN ISO 19840, ASTM B499/D1186/D1400/D7091/E376/G12, BS3900-C5, SSPC-PA2, etc., calibration The certificate is available, the system language is Chinese and English, the display screen is a high-resolution color LCD screen, the data interface is USB, and the supporting software is available. The weight of the whole machine is 140g (excluding batteries), the size of the whole machine is 137*61*28mm, and the data storage is 100,000 Measured value, 1000 groups, test environment non-ferrous metal substrate non-conductive coating environment, Defelsko calibration standard STDA2 | |
![]() | Defelsko PosiTector 6000 F45S1 Coating Thickness Gauge |
| Specification parameters: measurement principle magnetic induction, measurement range 0~1150μm, error range ±3%, resolution 0.1μm, probe F45S1 probe (45°miniature), statistical function average value, maximum value, minimum value, number of tests, standard deviation, The functions shown in the picture are, power supply 3*AAA alkaline batteries, meeting the standards ISO 2178/2360/2808, PrEN ISO 19840, ASTM B499/D1186/D1400/D7091/E376/G12, BS3900-C5, SSPC-PA2, etc. Calibration certificate Yes, the system language is Chinese and English, the display screen is high-resolution LCD screen, the data interface is USB, the supporting software is available, the weight of the whole machine is 140g (excluding batteries), the size of the whole machine is 137*61*28mm, and the data storage is 250 measured values , test environment ferrous metal substrate non-magnetic coating environment, Defelsko calibration standard STDS2, STDA2 | |
![]() | Defelsko PosiTector 6000 F90S3 Coating Thickness Gauge |
| Specifications: Measuring principle magnetic induction, measuring range 0~1150μm, error range ±3%, statistical function color display, can record/download 100,000 readings, machine weight 140 g (without battery), machine size 137*61 *28mm, probe split 90° miniature probe, test environment ferrous metal substrate non-magnetic coating environment, Defelsko calibration standard STDS2 | |
![]() | Defelsko PosiTector 6000 N0S1 Coating Thickness Gauge |
| Specification parameters: Measuring principle eddy current, measuring range 0~625μm, error range ±3%, resolution 0.1μm, probe N0S1 probe (0°miniature), statistical function average value, maximum value, minimum value, number of tests, standard deviation , no function shown in the picture, power supply 3*AAA alkaline batteries, meet the standards ISO 2178/2360/2808, PrEN ISO 19840, ASTM B499/D1186/D1400/D7091/E376/G12, BS3900-C5, SSPC-PA2, etc., calibration The certificate is available, the system language is Chinese and English, the display screen is a high-resolution LCD screen, the data interface is USB, and the supporting software is available. The weight of the whole machine is 140g (excluding batteries), the size of the whole machine is 137*61*28mm, and the data storage is 250 measurements Value, test environment non-ferrous metal substrate non-conductive coating environment, Defelsko calibration standard STDS2, STDA2 | |
![]() | Defelsko PosiTector 6000 F0S1 Coating Thickness Gauge |
| Specifications: Measuring principle magnetic induction, measuring range 0~625μm, error range ±3%, machine weight 165g (excluding battery), machine size 146*64*31mm | |