| model | temperature range ℃ | Temperature uniformity (horizontal/vertical °C) | Inner tank size mm | Total capacity (L) | Working tank opening mm 2 | Cooling capacity W pure water at 20°C | Outer circulation pump flow L/min |
| DC-0506 | -5~100 | ±0.05 | 275*195*120 | 6 | 180*140 | 600 | 13 |
| DC-0510 | -5~100 | ±0.05 | 275*195*180 | 10 | 180*140 | 900 | 13 |
| DC-0515 | -5~100 | ±0.05 | 300*250*200 | 15 | 235*160 | 1500 | 13 |
| DC-0520 | -5~100 | ±0.05 | 300*250*270 | 20 | 235*160 | 2000 | 13 |
| DC-0530 | -5~100 | ±0.05 | 440*325*210 | 30 | 310*280 | 2700 | 13 |
| DC-0550 | -5~100 | ±0.05 | 500*340*300 | 50 | 350*300 | 4000 | 13 |
| DC-05100 | -5~100 | ±0.05 | 625*400*400 | 100 | 480*380 | 7000 | 13 |
| DC-1006 | -10~100 | ±0.05 | 275*195*120 | 6 | 180*140 | 800 | 13 |
| DC-1010 | -10~100 | ±0.05 | 275*195*180 | 10 | 180*140 | 1200 | 13 |
| DC-1015 | -10~100 | ±0.05 | 300*250*200 | 15 | 235*160 | 1800 | 13 |
| DC-1020 | -10~100 | ±0.05 | 300*250*270 | 20 | 235*160 | 2300 | 13 |
| DC-1030 | -10~100 | ±0.05 | 440*325*210 | 30 | 310*280 | 3000 | 13 |
| DC-1050 | -10~100 | ±0.05 | 500*340*300 | 50 | 350*300 | 4300 | 13 |
| DC-10100 | -10~100 | ±0.05 | 625*400*400 | 100 | 480*380 | 7500 | 13 |
| DC-2006 | -20~100 | ±0.05 | 275*195*120 | 6 | 180*140 | 1200 | 13 |
| DC-2010 | -20~100 | ±0.05 | 275*195*180 | 10 | 180*140 | 1600 | 13 |
| DC-2015 | -20~100 | ±0.05 | 300*250*200 | 15 | 235*160 | 2200 | 13 |
| DC-2020 | -20~100 | ±0.05 | 300*250*270 | 20 | 235*160 | 2700 | 13 |
| DC-2030 | -20~100 | ±0.05 | 440*325*210 | 30 | 310*280 | 3400 | 13 |
| DC-2050 | -20~100 | ±0.05 | 500*340*300 | 50 | 350*300 | 4700 | 13 |
| DC-20100 | -20~100 | ±0.05 | 625*400*400 | 100 | 480*380 | 7900 | 13 |
| DC-3006 | -30~100 | ±0.05 | 275*195*120 | 6 | 180*140 | 1700 | 13 |
| DC-3010 | -30~100 | ±0.05 | 275*195*180 | 10 | 180*140 | 2100 | 13 |
| DC-3015 | -30~100 | ±0.05 | 300*250*200 | 15 | 235*160 | 2700 | 13 |
| DC-3020 | -30~100 | ±0.05 | 300*250*270 | 20 | 235*160 | 3200 | 13 |
| DC-3030 | -30~100 | ±0.05 | 440*325*210 | 30 | 310*280 | 3900 | 13 |
| DC-3050 | -30~100 | ±0.05 | 500*340*300 | 50 | 350*300 | 5200 | 13 |
| DC-30100 | -30~100 | ±0.05 | 625*400*400 | 100 | 480*380 | 8400 | 13 |
| DC-4006 | -40~100 | ±0.05 | 275*195*120 | 6 | 180*140 | 2300 | 13 |
| DC-4010 | -40~100 | ±0.05 | 275*195*180 | 10 | 180*140 | 2900 | 13 |
| DC-4015 | -40~100 | ±0.05 | 300*250*200 | 15 | 235*160 | 3400 | 13 |
| DC-4020 | -40~100 | ±0.05 | 300*250*270 | 20 | 235*160 | 3900 | 13 |
| DC-4030 | -40~100 | ±0.05 | 440*325*210 | 30 | 310*280 | 4600 | 13 |
| DC-4050 | -40~100 | ±0.05 | 500*340*300 | 50 | 350*300 | 5800 | 13 |
| DC-40100 | -40~100 | ±0.05 | 625*400*400 | 100 | 480*380 | 9000 | 13 |
| DC-5006 | -50~100 | ±0.05 | 275*195*120 | 6 | 180*140 | 2700 | 13 |
| DC-5010 | -50~100 | ±0.05 | 275*195*180 | 10 | 180*140 | 3400 | 13 |
| DC-5015 | -50~100 | ±0.05 | 300*250*200 | 15 | 235*160 | 3900 | 13 |
| DC-5020 | -50~100 | ±0.05 | 300*250*270 | 20 | 235*160 | 4500 | 13 |
| DC-5030 | -50~100 | ±0.05 | 440*325*210 | 30 | 310*280 | 5200 | 13 |
| DC-5050 | -50~100 | ±0.05 | 500*340*300 | 50 | 350*300 | 6400 | 13 |
| DC-50100 | -50~100 | ±0.05 | 625*400*400 | 100 | 480*380 | 9800 | 13 |
| DC-6006 | -60~100 | ±0.05 | 275*195*120 | 6 | 180*140 | 3500 | 13 |
| DC-6010 | -60~100 | ±0.05 | 275*195*180 | 10 | 180*140 | 4200 | 13 |
| DC-6015 | -60~100 | ±0.05 | 300*250*200 | 15 | 235*160 | 4700 | 13 |
| DC-6020 | -60~100 | ±0.05 | 300*250*270 | 20 | 235*160 | 5300 | 13 |
| DC-6030 | -60~100 | ±0.05 | 440*325*210 | 30 | 310*280 | 6000 | 13 |
| DC-6050 | -60~100 | ±0.05 | 500*340*300 | 50 | 350*300 | 7200 | 13 |
| DC-60100 | -60~100 | ±0.05 | 625*400*400 | 100 | 480*380 | 10600 | 13 |
NLDC low temperature thermostat series selection table
Guess you like it
-
-
RONGHUA DHH-5-5 Thermostat 5L$ 685.00 -
-
-
-
Relevant knowledge
- 1Difference between Thermostatic bath and Water bath
- 2How to choose a laboratory constant temperature bath?
- 3Thermostatic bath working principle and its application in viscosity measurement
- 4How to install the Rotational Viscometer on the thermostatic tank?
- 5Detection instrument scheme | Preparation of graphene oxide film and study on atmospheric purification mechanism
- 6Operation steps and precautions of Tianling thermostat
- 7Tips for using thermostat
- 8GDH series ultra-high precision low temperature thermostat tank selection table
- 9GH series ultra-high precision constant temperature water and oil tank selection table