In daily work, customers often say that they want to buy an Incubator. But after consulting, it was found that what the customer really needed was a constant temperature and Humidity Chamber covering humidity and low temperature functions. So what is the difference between a constant temperature and Humidity Chamber and a constant temperature box?
The functions of the constant temperature and Humidity Chamber and the constant temperature box are different
Both the constant temperature and Humidity Chamber and the constant temperature and humidity chamber belong to the temperature and humidity series environmental test equipment. While the two devices don't look much different on the outside, they're actually very different in functionality.
Since the constant temperature and Humidity Chamber has better performance than the constant temperature and Humidity Chamber, it can also be said that it was developed on the basis of the constant temperature and Humidity Chamber.
The Incubator is a Test Chamber with a room temperature ranging from 25 degrees Celsius to a high temperature of 400 degrees Celsius. It has the functions of high temperature aging test and high temperature baking. During the temperature rise process, the temperature is kept constant to detect and test the high temperature resistance of the tested product, or to achieve the purpose of drying the product by heating. At present, it is widely used in various industries, especially the electronic components industry.
The constant temperature and Humidity Chamber is a kind of damp heat aging Test Chamber, which has the functions of high temperature, low temperature and humidity. The main function is the damp heat aging test function. It also has independent high temperature test, low temperature test and other functions. The constant temperature and Humidity Chamber is a very powerful Test Chamber equipment, which is widely used in various industries, scientific research institutes and universities.
Humidity test in constant temperature and Humidity Chamber
When doing the humidity test in a constant temperature and humidity room, the wet ball gauze used needs to be special. The fabric of this gauze needs to be woven from linen, and the wet ball gauze needs to be replaced every 3-6 months, otherwise it may affect the test. accuracy. It needs to be placed in the reservoir when changing the gauze.
If the high temperature does not require humidity for a long time, the wet ball gauze can be removed, otherwise the wet ball gauze will become very hard under continuous high temperature conditions, which will cause it to not absorb water.