Steam aging test is suitable for electronic connectors, semiconductor ICs, transistors, diodes, liquid crystal LCDs, chip resistors, capacitors, electronic components, electronic components, metal pins, tin pin resistance tests, accelerated life tests, and conductors, passive Oxidation test of components and parts pins.
Construction, installation and operation of steam aging Test Chambers.
Structure: control panel, cover and drawer, cover handle, box, electrical cabinet, test area: 4 drawers, 100*540*260mm (customizable)
control Panel
1. Power switch: control all the power of the machine. Machines need to work and need to be turned on.
2. Timer: set and control test time
3. Temperature controller: control the temperature of the heating function
4. Timer switch: control the opening and closing of the timer. It needs to be turned on at regular intervals and shut down at irregular intervals
5. Low water level light: Indicates the inner tank water level. When the water is insufficient, the indicator light is on and cannot be heated at the same time; when the water is enough, the light is off, and the equipment can be heated only when the water level is reached.
6. Output light: heating indication
7. End of test
Install the power supply
1. Use the power source marked on the machine.
2. Pay attention to the installation of wires, avoid trampling and damage leakage, and ensure the safety of outside wires.
3. Connect the matching voltage socket or no fuse switch, turn on the switch ON/OFF, wait for the power indicator to light up, and the user can set the temperature control by himself.
4. Detailed power supply description:
one. Voltage 220V;
bay. Heating power 2.5kw
The red line is: FireWire
The blue line is: zero line
The black or colored wire is: ground wire
operate
1. Turn on the power first, check for leakage,
2. There is a water pipe connector on the back of the aging test box, which can automatically add water after connection; if the water pipe is not connected, open the cover and add water when water is needed;
3. Turn on the control switch and power switch on the operation panel. After turning on the power switch, the thermostat can display that the power supply is normal and can be used continuously;
4. After power on, the low water level light will indicate. Please add water. After the indicator light goes out, set the temperature to heat; when adding water manually, please open the lid to add water.