$127.00
SE
TRUIT TR 1005/2 paints DIN Viscosity Cup outflow aperture 2mm
25 to 150 seconds
Desktop, aluminum alloy material, according to DIN 53211 standard, outflow aperture φ2.0mm, viscosity range 15~ 30cst.

$127.00
SE
TRUIT TR 1005/8 Benchtop DIN Cup, T Cup, Outflow Aperture 8mm
F8.0mm25 to 150 seconds
Desktop, aluminum alloy material, in line with DIN 53211 standard, outflow aperture φ8.0mm, viscosity range 1200~3000cst.

$127.00
SE
TRUIT TR 1004/2.5 French standard Viscosity Cup aperture φ2.5mm
30 to 300 seconds
The outflow time is 30~300s, the outflow aperture is 2.5mm, the viscosity measurement range is 5~ 140cst, and the aluminum alloy material is used.

$127.00
SE
TRUIT TR 1004/8 French standard cup, aperture φ8.0mm
F8.0mm30 to 300 seconds
The outflow time is 30~300s, the outflow aperture is 8mm, the measurement viscosity range is 700~11500cst, and the aluminum alloy material is used.

$127.00
SE
TRUIT TR 1005/4 DIN Viscosity Cup outflow aperture 4mm
F4.0mm25 to 150 seconds
Desktop, aluminum alloy material, in line with DIN 53211 standard, outflow aperture φ4.0mm, viscosity range 112~ 685cst.

$127.00
SE
TRUIT TR 1008/8 ISO cup Viscosity Cup φ8.0mm
F8.0mm
The measurement range is 600~2000cst, the outflow aperture is φ8.0mm. It is made of anodic oxidation aluminum, and the nozzle is made of stainless steel.

$127.00
SE
TRUIT TR 1004/6 French standard cup, aperture φ6.0mm
f6.0mm30 to 300 seconds
The outflow time is 30~300s, the outflow aperture is 6mm, the measurement viscosity range is 510~5100cst, and the aluminum alloy material is used.

$127.00
SE
TRUIT TR 1008/5 ISO standard Viscosity Cup φ5.0mm
The measurement range is 91~ 325cst, the outflow aperture is φ5.0mm. It is made of anodic oxidation aluminum, and the nozzle is made of stainless steel.

$127.00
SE
TRUIT TR 1002/2 FORD Viscosity Cup outflow aperture φ2.53mm
40~100sec
In line with ASTM standards, the outflow aperture is φ2.53mm, the measurement viscosity range is 25~ 120cst, the filter is made of high-quality stainless steel, and the volume is 100ml.

$127.00
SE
TRUIT TR 1004/4 French standard Viscosity Cup aperture φ4.0mm
F4.0mm30 to 300 seconds
The outflow time is 30~300s, the outflow aperture is 4mm, the measurement viscosity range is 50~1100cst, and the aluminum alloy material is used.

$127.00
SE
TRUIT TR 1008/3 ISO Viscosity Cup φ3.0mm
The measurement range is 7~ 42cst, the outflow aperture is φ3.0mm. It is made of anodic oxidation aluminum, and the nozzle is made of stainless steel.

$127.00
SE
TRUIT TR 1002/1 ASTM Ford Viscosity Cup outflow aperture φ1.90mm
55~100sec
In line with ASTM standards, the outflow aperture is φ1.90mm, the measurement viscosity range is 10~35cst, the filter is made of high-quality stainless steel, and the volume is 100ml.

$127.00
SE
TRUIT TR 1008/6 ISO Viscosity Cup φ6.0mm
f6.0mm
The measurement range is 188~ 684cst, the outflow aperture is φ6.0mm. It is made of anodic oxidation aluminum, and the nozzle is made of stainless steel.

$127.00
SE
TRUIT TR 1002/3 FORD Viscosity Cup outflow aperture φ3.40mm
25~105sec
In line with ASTM standards, the outflow aperture is φ3.40mm, the measurement viscosity range is 49~ 220cst, the filter is made of high-quality stainless steel, and the volume is 100ml.

$192.00
SE
Ander LND-2 (4 #) No. 4 ISO cup with bracket Viscosity range 35~ 135cst
4mmISO 2431

$192.00
SE
Ander LND-2 (3 #) No. 3 ISO cup with bracket Viscosity range 7~ 40cst
3mmISO 2431

$403.00
ERICHSEN 243/II-4mm Viscosity Cup
4mmDIN 53 211 SNV 37 110 SIS 184 115
Viscosity range 90~682cSt, flow hole diameter 4mm, cup body material anodic oxidation aluminum, filter material stainless steel, Applicable standard DIN 53 211 SNV 37 110 SIS 184 115.

$486.00
SE
TQC No. 4 Ford Ford Viscosity Cup ASTM4 Viscosity Cup 4.1mm
4.1mm30~100sASTM D1200‘FORD
Viscosity cup aluminum. ASTM D1200 "FORD" with fixed nozzle 4mm

$413.00
SE
TQC VF2001 DIN cup, aluminum alloy Viscosity Cup 3mm
3mmApproximate DIN 53211
Viscosity cup, aluminium. DIN 53211 with fixed nozzle 3mm

$426.00
SE
TQC VF2020 Viscosity Cup standard DIN 53211 for measurement of viscosity of paints, varnishes and other liquids (filter to be purchased separately)
1/2/3/4/5/6/7/8mmApproximate DIN 53211
Viscosity cup DIN 53211 for int. Variable nozzle

$455.00
SE
TQC VF2049 desktop 4 Viscosity Cup 4mm filter
4mmISO 2431
Viscosity cup aluminum. ISO 2431 with fixed nozzle 4 mm

$127.00
SE
QND-4C coating 4 cups YONGLIDA laboratory brass coating 4 cups
4mm0~150sGB/T 1723
Desktop with bracket; aperture 4mm; brass material; meets GB/T1723 standard.

$394.00
SE
TQC VF1999 DIN cup, aluminum alloy, filter diameter 4mm
4mm25~150sApproximate DIN 53211
DIN Viscosity Cup, aluminium. DIN 53211 with fixed nozzle 4mm

$486.00
SE
TQC No. 2 Ford Ford Viscosity Cup ASTM2 Viscosity Cup 2.53mm
2.53mm40~100sASTM D1200‘FORD
Viscosity cup, aluminum. ASTM D1200 "FORD" with fixed nozzle 2mm

$428.00
SE
TQC VF2196 Afnor Viscosity Cup flow hole 4mm
4mmNF T030-014
TQC SHEEN Afnor 4 viscosity Flow Cup

$452.00
SE
TQC VF2048 desktop No. 3 Viscosity Cup 3mm ISO2431
3mmISO 2431
Viscosity cup type ISO 2431 with fixed nozzle 3 mm

$428.00
SE
TQC VF2198 Afnor Viscosity Cup flow hole 8mm
8mmNF T030-014
TQC SHEEN Afnor 8 viscosity Flow Cup

$428.00
SE
TQC VF2195 Afnor Viscosity Cup flow hole 2.5mm
2.5mmNF T030-014
TQC SHEEN Afnor 2.5mm viscosity Flow Cup

$486.00
SE
TQC No. 5 Ford Ford Viscosity Cup, model VF2033, filter aperture 5.2mm
5.2mm30~100sASTM D1200‘FORD
Viscosity cup ASTM D1200 "FORD" with fixed nozzle 5mm