$125.00
SE
TRUIT TR 1004/8 French standard cup, aperture φ8.0mm
F8.0mm30 to 300 seconds
The outflow time is 30~300s, the outflow aperture is 8mm, the measurement viscosity range is 700~11500cst, and the aluminum alloy material is used.

$125.00
SE
TRUIT TR 1004/6 French standard cup, aperture φ6.0mm
f6.0mm30 to 300 seconds
The outflow time is 30~300s, the outflow aperture is 6mm, the measurement viscosity range is 510~5100cst, and the aluminum alloy material is used.

$125.00
SE
TRUIT TR 1008/8 ISO cup Viscosity Cup φ8.0mm
F8.0mm
The measurement range is 600~2000cst, the outflow aperture is φ8.0mm. It is made of anodic oxidation aluminum, and the nozzle is made of stainless steel.

$125.00
SE
TRUIT TR 1002/2 FORD Viscosity Cup outflow aperture φ2.53mm
40~100sec
In line with ASTM standards, the outflow aperture is φ2.53mm, the measurement viscosity range is 25~ 120cst, the filter is made of high-quality stainless steel, and the volume is 100ml.

$125.00
SE
TRUIT TR 1008/5 ISO standard Viscosity Cup φ5.0mm
The measurement range is 91~ 325cst, the outflow aperture is φ5.0mm. It is made of anodic oxidation aluminum, and the nozzle is made of stainless steel.

$125.00
SE
TRUIT TR 1004/4 French standard Viscosity Cup aperture φ4.0mm
F4.0mm30 to 300 seconds
The outflow time is 30~300s, the outflow aperture is 4mm, the measurement viscosity range is 50~1100cst, and the aluminum alloy material is used.

$125.00
SE
TRUIT TR 1008/3 ISO Viscosity Cup φ3.0mm
The measurement range is 7~ 42cst, the outflow aperture is φ3.0mm. It is made of anodic oxidation aluminum, and the nozzle is made of stainless steel.

$125.00
SE
TRUIT TR 1002/1 ASTM Ford Viscosity Cup outflow aperture φ1.90mm
55~100sec
In line with ASTM standards, the outflow aperture is φ1.90mm, the measurement viscosity range is 10~35cst, the filter is made of high-quality stainless steel, and the volume is 100ml.

$125.00
SE
TRUIT TR 1008/6 ISO Viscosity Cup φ6.0mm
f6.0mm
The measurement range is 188~ 684cst, the outflow aperture is φ6.0mm. It is made of anodic oxidation aluminum, and the nozzle is made of stainless steel.

$125.00
SE
TRUIT TR 1002/3 FORD Viscosity Cup outflow aperture φ3.40mm
25~105sec
In line with ASTM standards, the outflow aperture is φ3.40mm, the measurement viscosity range is 49~ 220cst, the filter is made of high-quality stainless steel, and the volume is 100ml.

$189.00
SE
Ander LND-2 (4 #) No. 4 ISO cup with bracket Viscosity range 35~ 135cst
4mmISO 2431

$189.00
SE
Ander LND-2 (3 #) No. 3 ISO cup with bracket Viscosity range 7~ 40cst
3mmISO 2431

$125.00
SE
QND-4C coating 4 cups YONGLIDA laboratory brass coating 4 cups
4mm0~150sGB/T 1723
Desktop with bracket; aperture 4mm; brass material; meets GB/T1723 standard.

$117.00
BoutiqueSE
YUEPING NDJ-5 coated with 4 cups Viscometer GB/T1723 standard, the error is only 3% Measurement
4mm30~100sGB/T 1723
GB/T1723 standard, the error is only 3%, can be measured, copper cup body, outflow hole is stainless steel, cost-effective, desktop with bracket.

$161.00
SE
YONGLIDA FORD-4 Ford Viscosity Cup paints viscosity measurement
4.12mmASTM D1200
Viscosity range 70~370cSt, flow hole diameter 4.12mm, capacity 100ml, cup body material aluminum alloy, filter material stainless steel, Applicable standard ASTM D1200.

$145.00
SE
YONGLIDA QNB-8 ISO flow Viscosity Cup 8mm aperture Measurement range 600~2000cSt
8mm30~100sISO 2431、GB/T 6753.4
Viscosity range 600~2000cSt, outflow time 30~100s, flow hole diameter 8mm, cup body material aluminum alloy, filter material stainless steel, Applicable standards ISO 2431, GB/T 6753.4.

$229.00
SE
QNB ISO Flow Cup set YONGLIDA contains 3, 4 and 6 Flow Cups
3/4/6mm30~100sISO 2431-1993、GB/T 6753.4-98
Outflow time 30~100s, flow hole diameter 3/4/6 mm, cup body material aluminum alloy, filter material stainless steel, Applicable standard ISO 2431-1993, GB/T 6753.4-98.

$164.00
SE
YONGLIDA QNB-ISO-4 ISO Flow Cup (including bracket) viscosity range: 34~ 135cst
4mmISO 2431、GB/T 6753.4
Viscosity range 34~ 135cSt, flow hole diameter 4mm, cup body material aluminum alloy, filter material stainless steel, applicable standards ISO 2431, GB/T 6753.4.

$141.00
SE
YONGLIDA QNB-4 ISO flow Viscosity Cup 4mm aperture Measurement range 34~ 135cSt
4mmISO 2431、GB/T 6753.4
Viscosity range 34~ 135cSt, flow hole diameter 4mm, cup body material aluminum alloy, filter material stainless steel, Applicable standards ISO 2431, GB/T 6753.4.

$147.00
SE
QND-1 coated 1 Viscosity Cup YONGLIDA aluminum 50ml volume with round Water Bath cover
5.6mmGB/T 1723
Coating 1 Viscometer, flow hole diameter 5.6mm, flow hole diameter error +/- 0.2mm, capacity 50ml, cup body material aluminum, Applicable standard GB/T 1723

$164.00
SE
YONGLIDA FORD-5 Ford Viscosity Cup Flow Cup method
5.2mmASTM D1200
Viscosity range 200~1200cSt, flow hole diameter 5.2mm, capacity 100ml, cup body material aluminum alloy, filter material stainless steel, Applicable standard ASTM D1200.

$122.00
SE
QND-4B coated 4 Viscosity Cups YONGLIDA Coating inks Aluminum coated 4 Viscosity Cups
4mmGB/T 1723
Flow hole diameter 4mm, capacity 100ml, cup body material aluminum, Applicable standard GB/T 1723, Environmental temperature 25 +/- 2 ℃, correction factor 0.97~ 1.03.

$164.00
SE
YONGLIDA QNB-ISO-3 ISO Flow Cup (including bracket) viscosity range: 7~ 42cst
3mmISO 2431、GB/T 6753.4
Viscosity range 7~ 42cSt, flow hole diameter 3mm, cup body material aluminum alloy, filter material stainless steel, applicable standards ISO 2431, GB/T 6753.4.

$161.00
SE
YONGLIDA FORD-3 Ford Viscosity Cup fluid second measuring cup
3.4mmASTM D1200
Viscosity range 49~ 220cSt, flow hole diameter 3.4mm, capacity 100ml, cup body material aluminum alloy, filter material stainless steel, Applicable standard ASTM D1200.

$141.00
SE
YONGLIDA QNB-6 ISO flow Viscosity Cup 6mm Aperture Measurement range 188~ 684cSt
6mmISO 2431、GB/T 6753.4
Viscosity range 188~ 684cSt, flow hole diameter 6mm, cup body material aluminum alloy, filter material stainless steel, Applicable standards ISO 2431, GB/T 6753.4.

$105.00
SE
QND-4A coated with 4 Viscometer YONGLIDA bakelite material
4mm0~150sGB/T 1723
Outflow time 0~150s, flow hole diameter 4mm, capacity 100ml, cup body material bakelite, Applicable standard GB/T 1723, Environmental temperature 25 +/- 2 ℃, correction coefficient 0.97~ 1.03.

$161.00
SE
YONGLIDA FORD-1 Ford Viscosity Cup Paints Flow Cup
1.9mmASTM D1200
Viscosity range 10~35cSt, flow hole diameter 1.9mm, capacity 100ml, cup body material aluminum alloy, filter material stainless steel, Applicable standard ASTM D1200.

$161.00
SE
YONGLIDA FORD-2 Ford Viscosity Cup varnish viscosity measurement cup
2.53mmASTM D1200
Viscosity range 25~ 120cSt, flow hole diameter 2.53mm, capacity 100ml, cup body material aluminum alloy, filter material stainless steel, Applicable standard ASTM D1200.

$164.00
SE
YONGLIDA QNB-ISO-5 ISO Flow Cup (including bracket) viscosity range: 91~ 326cst
5mmISO 2431、GB/T 6753.4
Viscosity range 91~ 326cSt, flow hole diameter 5mm, cup body material aluminum alloy, filter material stainless steel, applicable standards ISO 2431, GB/T 6753.4.

$164.00
SE
YONGLIDA QNB-ISO-6 ISO Flow Cup (including bracket) viscosity range: 188~ 684cst
6mmISO 2431、GB/T 6753.4
Viscosity range 188~ 684cSt, flow hole diameter 6mm, cup body material aluminum alloy, filter material stainless steel, applicable standards ISO 2431, GB/T 6753.4.

If you don't know how to choose "Viscosity Cup", please consult customer service.