$786.00
SE
TONGAO TR-136H Water Quality Volatile Phenol Tester
volatile phenol0~10Mg/L (measured in sections)
Detect the content of volatile phenols, the range is 0.1mg/L-10mg/L (measured in sections), no digestion is required, the detection time is 10 to 15 minutes, and the digestion Colorimetric integrated detection is used, which conforms to the HJ503-2009 standard.

$786.00
SE
TONGAO TR-740H Nickel meter, water quality heavy metals Detector
nickel0~4Mg/L (measured in sections)
Detection of nickel content, the range is 0.1mg/L-4mg/L (segmented determination), no digestion is required, the detection time is 5 to 10 minutes, and the digestion Colorimetric integrated detection is used, which conforms to the GB11910-89 standard.

$540.00
SE
HANNA HI97742 2-in-1, Iron LR and Manganese LR Portable Photometer
Measurement range of iron 0.00 to 1.60 mg/L (as Mn), resolution 0.01 mg/L, Mn Measurement range 0 to 300 μg/L (as Mn), resolution 1 μg/L, commonly used in environment monitoring, wastewater treatment, drinking water mass detection and other fields.

$2434.00
SE
TONGAO TR-108H COD (Chemical Oxygen Demand) Tester
0~10000Mg/L (measured in sections)
Digestion Colorimetric integrated tube detection, detection of COD concentration value, range 5mg/L-10000mg/L (segmented), Sensitivity up to 0.001mg/L, with digestion instrument and pipette gun.

$540.00
SE
HANNA HI97711 Portable waterproof residual chlorine/free chlorine/total chlorine photometer
Residual chlorine measurement range: 0.00 to 5.00mg/L (asCl2), resolution: 0.01mg/L, accuracy: +/- 0.03mg/L +/- 3% of reading, total chlorine measurement range 0.00 to 5.00mg/L (asCl2), built-in reaction Timer to ensure consistent results between sample measurements and users.

$540.00
SE
HANNA HI97739 Fluoride HR Portable Photometer
0.00-20.00mg/L
Measurement range 0.00-20 mg/L, resolution 0.01mg/L, accuracy @25 ℃: +/- 3 %; +/- 0.5mg/L of reading, commonly used in drinking water monitoring, industrial production process control and other fields to ensure that the concentration of fluoride ions in water is within the safe range.

$540.00
SE
HANNA HI97771 residual chlorine [free chlorine] -UHR total chlorine Portable Photometer
Residual chlorine Measurement range 0.00 to 5.00 mg/L (as Cl2), resolution 0.01 mg/L, total chlorine Measurement range 0to 500 mg/L (as Cl2), resolution 1 mg/L, using innovative Optical inspection system design, with good accuracy.

$786.00
SE
TONGAO TR-701H Water Quality Nitrate Nitrogen Tester
nitrate nitrogen0~10Mg/L (measured in sections)
Detection of nitrate nitrogen content, the range is 0.5mg/L-10mg/L (measured in sections), no digestion is required, the detection time is 10 to 15 minutes, and the digestion Colorimetric integrated detection is used, which conforms to the standard of "Water Quality, Chromotropic Acid Spectrophotometry".

$540.00
SE
HANNA HI97769 Surfactant [SDBS] Portable Photometer
Measurement range 0.00 to 3.50 mg/L (as SDBS), resolution 0.01 mg/L, accuracy @25 ℃: +/- 0.04 mg/L +/- 3% of reading, widely used in water treatment, environment monitoring, detergent production and detergent residue detection.

$540.00
SE
HANNA HI97750 Potassium/potassium oxidation Portable Photometer
Measurement range 0.0 to 20.0 mg/L; 10 to 100 mg/L (as K), resolution 0.1 mg/L, accuracy @25 ℃: +/- 3 mg/L +/- 7% of reading, commonly used in soil and agricultural analysis to assess soil fertility and crop nutritional status, it can also be used to monitor oxidation potassium content in wastewater, etc.

$540.00
SE
HANNA HI97746 Iron [LR] Portable Photometer
Measurement range of iron 0.00 to 1.60 mg/L (as Mn), resolution 0.01 mg/L, accuracy @25 ℃: +/- 0.01 mg/L +/- 8% of reading, commonly used in environment monitoring, water quality control, industrial process control and other fields to ensure that the iron concentration in water is within the safe range and meets the requirements of relevant standards and regulations.

$540.00
SE
HANNA HI97749 Hexavalent Chromium/Chromate/Dichromate [LR] Portable Photometer
Measurement range 0 to 300 μg/L (as Cr (VI)), resolution 1 μg/L, accuracy @25 ℃: +/- 10 μg/L +/- 4% of reading, commonly used in industrial wastewater treatment, environment monitoring and water quality control.

$540.00
SE
HANNA HI97720 calcium hardness Portable Photometer
Calcium hardness measurement range 0.00 to 2.70 mg/L (as CaCO3), resolution 0.01 mg/L, high quality Optical inspection filter, unique reference Detector to ensure measurement accuracy and accuracy.

$540.00
SE
HANNA HI97748 Manganese/potassiumhy permanganate [LR] Portable Photometer
Measurement range 0 to 300 μg/L (as Mn), resolution 1 μg/L, accuracy @25 ℃: +/- 10 μg/L +/- 3% of reading, commonly used in environment monitoring, drinking water mass detection, industrial process control and other fields.

$540.00
SE
HANNA HI97747 Copper [Cu, LR] Portable Waterproof Photometer
Measurement range 0.000 to 1.500 mg/L (as Cu2 +), resolution 0.001 mg/L, accuracy @25 ℃: +/- 0.010 mg/L +/- 5% of reading, commonly used in environment monitoring, wastewater treatment, drinking water mass detection and other fields.

$540.00
SE
HANNA HI97719 mg hardness photometer
Mg hardness measurement range 0.00 to 2.00 mg/L (as CaCO3), resolution 0.01 mg/L, accuracy @25 ℃ reading +/- 0.11 mg/L +/- 5%; High quality Optical inspection filter to ensure measurement accuracy and accuracy.

$1970.00
SE
LEICI JPSJ-606L Dissolved Oxygen Meter +/- 0.30mg/L
Dissolved oxygen, dissolved oxygen saturation, temperature

$521.00
SE
LEICI DGB-423 Optoelectronic Colorimetry Water Quality Analyzer Ammonia Nitrogen
ammonia nitrogen0.000~4.000
Measurement method Noll reagent method, light source wavelength 420nm, Measurement range 0.000~4.000, error of indication ≤ +/- 10%, Repeatability ≤ 3%,

$512.00
SE
LEICI DGB-404F Portable Hexavalent Chromium Tester, Hexavalent Chromium
0.00~2.00mg/L
Spectrophotometric method, spectrophotometry, can quickly and accurately measurement of hexavalent chromium in water, support multi-point calibrating and Data storage, can be connected to PC for data collection, with good waterproof and dustproof performance and power management function, suitable for the determination of hexavalent chromium in various water quality needs.