Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Result > Brand: JingQi Type:Single parameter >

      STIP-scan

      31 results
      Featured Hot Price Time
      JINGQI WD8101 Sulfate Tester
      $481.00 SE
      JINGQI WD8101 Sulfate Tester
      sulfate5.00~200.00mg/L
      Measurement range 5.00~200.00mg/L, error of indication ≤ +/- 5%, Repeatability ≤ 3%, Optical inspection Stability ≤ 0.002A/20min, LCD Chinese display, imported high performance, long life (100,000 hours), high luminance Light source, with narrow band filter system.
      Compare
      JINGQI WD8802 residual chlorine analyzer
      $481.00 SE
      JINGQI WD8802 residual chlorine analyzer
      Residual chlorine0.02~ 10.00Mg/L. Divided into two ranges: 0.02~ 2.00mg/L, 2~ 10.00mg/L.
      Measurement range 0.02~ 10.00mg/L. Divided into two ranges: 0.02~ 2.00mg/L, 2~ 10.00mg/L., error of indication ≤ +/- 3% FS, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8203 Nickel Tester
      $481.00 SE
      JINGQI WD8203 Nickel Tester
      nickel0.02~1.00mg/L
      Measurement range 0.02~ 1.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%, can automatically process the data and directly display the nickel concentration value of the water sample.
      Compare
      JINGQI WD9101 Precision Ammonia Nitrogen Tester
      $514.00 SE
      JINGQI WD9101 Precision Ammonia Nitrogen Tester
      0.02~25mg/L
      Quantity range 0.02~ 25mg/L, intrinsic error +/- 3% (F. S), Repeatability ≤ 2%, high-performance, low-power microcontroller and large-screen LCD, equipped with Chinese character menu
      Compare
      JINGQI WD8220 Hardness Tester
      $481.00 SE
      JINGQI WD8220 Hardness Tester
      Hardness0~200Mg/L (over dilute determination), divided into two ranges of 0~5.00 and 5~ 200mg/L
      Measurement range 0~200mg/L (over dilute measurement), divided into two ranges of 0~5.00 and 5~ 200mg/L, error of indication ≤ +/- 5%, Optical inspection Stability ≤ 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8208 Cadmium Tester
      $481.00 SE
      JINGQI WD8208 Cadmium Tester
      cadmium0.00~10.00mg/L
      Measurement range 0.00~10.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8801 residual chlorine analyzer
      $481.00 SE
      JINGQI WD8801 residual chlorine analyzer
      Residual chlorine0.02~ 10.00Mg/L. Divided into two ranges: 0.02~ 2.00mg/L, 2~ 10.00mg/L.
      Measurement range 0.02~ 10.00mg/L. Divided into two ranges: 0.02~ 2.00mg/L, 2~ 10.00mg/L. Error of indication ≤ +/- 3% FS, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%.
      Compare
      JINGQI BOD5-870 Direct reading BOD Tester
      $722.00 SE
      JINGQI BOD5-870 Direct reading BOD Tester
      0~1000mg/L
      Measurement range 0~1000mg/L, Measurement accuracy conforms to the national standard "GB7488", direct reading on the display screen, batch processing capacity of 8 water samples, foster temperature 20 ℃ +/- 1 ℃
      Compare
      JINGQI WD9101P Precision Ammonia Nitrogen Tester with Printing Function
      $652.00 SE
      JINGQI WD9101P Precision Ammonia Nitrogen Tester with Printing Function
      0.02~25mg/L
      Measurement range 0.02~ 25mg/L, intrinsic error ≤ +/- 3% and 0.2 of the largest, Repeatability ≤ 2%, with printing function.
      Compare
      JINGQI WD8302 Water Volatile Phenol Tester
      $481.00 SE
      JINGQI WD8302 Water Volatile Phenol Tester
      volatile phenol0.20~10.0mg/L
      Measurement range 0.20~10.0mg/L, error of indication ≤ +/- 5%, Optical inspection Stability ≤ 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8201 Copper Tester
      $481.00 SE
      JINGQI WD8201 Copper Tester
      copper0.02~ 10.00Mg/L (divided into two ranges of 0.02~ 1.00mg/L, 1.00~10.00mg/L)
      Measurement range 0.02~ 10.00mg/L (divided into 0.02~ 1.00mg/L, 1.00~10.00mg/L two ranges), error of indication ≤ +/- 3%, can achieve high-precision and stable copper concentration measurement.
      Compare
      JINGQI WD8803 Chlorine dioxide Tester
      $481.00 SE
      JINGQI WD8803 Chlorine dioxide Tester
      chlorine dioxide0.05~25.00mg/L
      Measurement range 0.05~ 25.00mg/L, error of indication ≤ +/- 5% FS, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8218 Iodine Tester
      $481.00 SE
      JINGQI WD8218 Iodine Tester
      iodine0.0~0.8mg/L
      Measurement range 0.0~ 0.8mg/L, error of indication ≤ +/- 5%, Optical inspection Stability ≤ 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8202 Manganese Tester
      $481.00 SE
      JINGQI WD8202 Manganese Tester
      manganese0.02~5.00mg/L
      Measurement range 0.02~ 5.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%, can automatically process data and directly display the manganese concentration value of water samples.
      Compare
      JINGQI WD8104 Nitrite Tester
      $481.00 SE
      JINGQI WD8104 Nitrite Tester
      Nitrous acid0.02~5.00mg/L
      Measurement range 0.02~ 5.00mg/L, error of indication ≤ +/- 5%, minimum detection limit 0.01mg/L, large-screen LCD Chinese display, Chinese menu operation
      Compare
      JINGQI WD8213 Antimony Tester
      $481.00 SE
      JINGQI WD8213 Antimony Tester
      antimony0.10~5.00mg/L
      Measurement range 0.10~5.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8216 Silver Tester
      $481.00 SE
      JINGQI WD8216 Silver Tester
      silver0.01~1.00mg/L
      Measurement range 0.01~ 1.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8215 Lead Tester
      $481.00 SE
      JINGQI WD8215 Lead Tester
      lead0.01~0.50mg/L
      Measurement range 0.01~ 0.50mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8103 Nitrate Tester
      $481.00 SE
      JINGQI WD8103 Nitrate Tester
      Nitrate0.02~10.00mg/L
      Measurement range 0.02~ 10.00mg/L, error of indication ≤ +/- 5%, minimum detection limit 0.01mg/L, large-screen LCD Chinese display, Chinese menu operation.
      Compare
      JINGQI WD8210 Barium Tester
      $481.00 SE
      JINGQI WD8210 Barium Tester
      Barium0.06~3.00mg/L
      Measurement range 0.06~ 3.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8105 Cyanide Tester
      $481.00 SE
      JINGQI WD8105 Cyanide Tester
      cyanide0.01~0.50mg/L
      Measurement range 0.01~ 0.50mg/L, error of indication ≤ +/- 5%, resolution 0.01mg/L, Repeatability ≤ 3%, large-screen LCD Chinese display, Chinese menu operation.
      Compare
      JINGQI WD8219 Arsenic Tester
      $481.00 SE
      JINGQI WD8219 Arsenic Tester
      arsenic0.001~0.500mg/L
      Measurement range 0.001~ 0.500mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8102 phosphoric acid salt Tester
      $481.00 SE
      JINGQI WD8102 phosphoric acid salt Tester
      Phosphoric acid5.00~200.00mg/L
      Measurement range 5.00~200.00mg/L, error of indication ≤ +/- 5%, Repeatability ≤ 3%, LCD Chinese display, Chinese menu operation, simple and intuitive.
      Compare
      JINGQI WD8217 boron Tester
      $481.00 SE
      JINGQI WD8217 boron Tester
      boron0.1~1.0mg/L
      Measurement range 0.1~ 1.0mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8214 Lead Tester
      $481.00 SE
      JINGQI WD8214 Lead Tester
      0.01~0.50mg/L
      Measurement range 0.01~ 0.50mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8205 Hexavalent Chromium Tester
      $481.00 SE
      JINGQI WD8205 Hexavalent Chromium Tester
      hexavalent chromium0.01~1mg/L
      Measurement range 0.01~ 1mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8106 Sulfide Tester
      $481.00 SE
      JINGQI WD8106 Sulfide Tester
      sulfide0.01~1.00mg/L
      Measurement range 0.01~ 1.00mg/L, error of indication ≤ +/- 5%, resolution 0.01mg/L, Repeatability ≤ 3%, can achieve high-precision and stable sulfide concentration measurement.
      Compare
      JINGQI WD8107 Fluoride Tester
      $481.00 SE
      JINGQI WD8107 Fluoride Tester
      fluoride0.05~2.00mg/L
      Measurement range 0.05~ 2.00mg/L, error of indication ≤ +/- 5%, resolution 0.01mg/L, Repeatability ≤ 3%, large-screen LCD Chinese display and Chinese menu operation.
      Compare
      JINGQI WD8301 aniline Tester
      $481.00 SE
      JINGQI WD8301 aniline Tester
      Aniline0.03~1.00mg/L
      Measurement range 0.03~ 1.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability ≤ 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8204 Aluminum Tester
      $481.00 SE
      JINGQI WD8204 Aluminum Tester
      aluminum0.01~4.00mg/L
      Measurement range 0.01~ 4.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      If you don't know how to choose "STIP-scan", please consult customer service.
      Focus on online sales of Lab Testing Instruments