      Featured Hot Price Time
      TONGAO TR-109H Water Quality Ammonia Nitrogen Rapid Tester
      $786.00 SE
      TONGAO TR-109H Water Quality Ammonia Nitrogen Rapid Tester
      ammonia nitrogen0~50Mg/L (measured in sections)
      Detect the content of ammonia nitrogen, the range is 0.05mg/L-50mg/L, no digestion is required, and the digestion Colorimetric integrated detection is used, which conforms to the HJ535-2009 standard.
      Compare
      TONGAO TR-105H Water Quality Hexavalent Chromium Tester
      $786.00 SE
      TONGAO TR-105H Water Quality Hexavalent Chromium Tester
      hexavalent chromium0~5Mg/L (measured in sections)
      Detect the content of hexavalent chromium, the range is 0.01mg/L-5mg/L (measured in sections), no digestion is required, the detection time is 10 to 15 minutes, and the digestion Colorimetric integrated detection is used, which conforms to the GB7467-87 standard.
      Compare
      JINGQI WD8101 Sulfate Tester
      $481.00 SE
      JINGQI WD8101 Sulfate Tester
      sulfate5.00~200.00mg/L
      Measurement range 5.00~200.00mg/L, error of indication ≤ +/- 5%, Repeatability ≤ 3%, Optical inspection Stability ≤ 0.002A/20min, LCD Chinese display, imported high performance, long life (100,000 hours), high luminance Light source, with narrow band filter system.
      Compare
      LEICI JPSJ-605F Dissolved Oxygen Meter +/- 0.30mg/L
      $739.00 SE
      LEICI JPSJ-605F Dissolved Oxygen Meter +/- 0.30mg/L
      Dissolved oxygen concentration, dissolved oxygen saturation, dissolved oxygen current and temperature value
      Compare
      JINGQI WD8802 residual chlorine analyzer
      $481.00 SE
      JINGQI WD8802 residual chlorine analyzer
      Residual chlorine0.02~ 10.00Mg/L. Divided into two ranges: 0.02~ 2.00mg/L, 2~ 10.00mg/L.
      Measurement range 0.02~ 10.00mg/L. Divided into two ranges: 0.02~ 2.00mg/L, 2~ 10.00mg/L., error of indication ≤ +/- 3% FS, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8203 Nickel Tester
      $481.00 SE
      JINGQI WD8203 Nickel Tester
      nickel0.02~1.00mg/L
      Measurement range 0.02~ 1.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%, can automatically process the data and directly display the nickel concentration value of the water sample.
      Compare
      Bante821 standard portable Dissolved Oxygen Meter DO100 dissolved Oxygen electrode
      $464.00 SE
      Bante821 standard portable Dissolved Oxygen Meter DO100 dissolved Oxygen electrode
      Standard portable Dissolved Oxygen Meter, 1 or 2 point calibrated, automatic end point lock, 9 function parameters can be customized in the setting menu, the meter is suitable for measurement of dissolved oxygen concentration and percentage saturation of samples, Measurement accuracy: 0.2mg/L.
      Compare
      LEICI DGB-402F Portable residual chlorine total chlorine Tester
      $560.00 SE
      LEICI DGB-402F Portable residual chlorine total chlorine Tester
      Residual chlorine: (0.00~3.00) mg/L total chlorine: (0.00~3.00) mg/L
      Accurate measurement of residual chlorine and total chlorine in water, LED Light source with long life and high-performance microcontroller technology, support single and multi-point calibrating, Data storage, USB communication and waterproof and dustproof functions, suitable for drinking water, medical wastewater, swimming pool water and other water quality Determination of residual chlorine and total chlorine.
      Compare
      Bante322-UK Portable Water Quality Sclerometer British WH-UK Water Hardness electrode
      $742.00 SE
      Bante322-UK Portable Water Quality Sclerometer British WH-UK Water Hardness electrode
      Standard Portable Water Quality Sclerometer, 5-point button calibrated, optional Water Hardness Unit, the meter is suitable for measurement of calcium and magnesium ion concentration of samples, measurement accuracy: 1% F.S.
      Compare
      Bante980 laboratory Dissolved Oxygen Meter
      $464.00 SE
      Bante980 laboratory Dissolved Oxygen Meter
      Standard laboratory Dissolved Oxygen Meter, 1 or 2 point calibrated, 10 function parameters can be customized in the setting menu, the meter is suitable for daily laboratory applications, Measurement accuracy: 0.2mg/L.
      Compare
      JINGQI WD9101 Precision Ammonia Nitrogen Tester
      $514.00 SE
      JINGQI WD9101 Precision Ammonia Nitrogen Tester
      0.02~25mg/L
      Quantity range 0.02~ 25mg/L, intrinsic error +/- 3% (F. S), Repeatability ≤ 2%, high-performance, low-power microcontroller and large-screen LCD, equipped with Chinese character menu
      Compare
      JINGQI WD8220 Hardness Tester
      $481.00 SE
      JINGQI WD8220 Hardness Tester
      Hardness0~200Mg/L (over dilute determination), divided into two ranges of 0~5.00 and 5~ 200mg/L
      Measurement range 0~200mg/L (over dilute measurement), divided into two ranges of 0~5.00 and 5~ 200mg/L, error of indication ≤ +/- 5%, Optical inspection Stability ≤ 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8208 Cadmium Tester
      $481.00 SE
      JINGQI WD8208 Cadmium Tester
      cadmium0.00~10.00mg/L
      Measurement range 0.00~10.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8801 residual chlorine analyzer
      $481.00 SE
      JINGQI WD8801 residual chlorine analyzer
      Residual chlorine0.02~ 10.00Mg/L. Divided into two ranges: 0.02~ 2.00mg/L, 2~ 10.00mg/L.
      Measurement range 0.02~ 10.00mg/L. Divided into two ranges: 0.02~ 2.00mg/L, 2~ 10.00mg/L. Error of indication ≤ +/- 3% FS, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%.
      Compare
      JINGQI BOD5-870 Direct reading BOD Tester
      $722.00 SE
      JINGQI BOD5-870 Direct reading BOD Tester
      0~1000mg/L
      Measurement range 0~1000mg/L, Measurement accuracy conforms to the national standard "GB7488", direct reading on the display screen, batch processing capacity of 8 water samples, foster temperature 20 ℃ +/- 1 ℃
      Compare
      JINGQI WD9101P Precision Ammonia Nitrogen Tester with Printing Function
      $652.00 SE
      JINGQI WD9101P Precision Ammonia Nitrogen Tester with Printing Function
      0.02~25mg/L
      Measurement range 0.02~ 25mg/L, intrinsic error ≤ +/- 3% and 0.2 of the largest, Repeatability ≤ 2%, with printing function.
      Compare
      JINGQI WD8302 Water Volatile Phenol Tester
      $481.00 SE
      JINGQI WD8302 Water Volatile Phenol Tester
      volatile phenol0.20~10.0mg/L
      Measurement range 0.20~10.0mg/L, error of indication ≤ +/- 5%, Optical inspection Stability ≤ 0.002A/20min, Repeatability ≤ 3%
      Compare
      NOBOTECH ZS-680 Submerged Online Suspension Detector 0-500NTU
      $643.00 SE
      NOBOTECH ZS-680 Submerged Online Suspension Detector 0-500NTU
      0~10000Mg/L, the range can be customized
      Range 0-10000mg/L, good reproducibility, 316 stainless steel shell, invisible near monochrome Infrared source, multi-point correction, imported core accessories, can be customized range.
      Compare
      JINGQI WD8201 Copper Tester
      $481.00 SE
      JINGQI WD8201 Copper Tester
      copper0.02~ 10.00Mg/L (divided into two ranges of 0.02~ 1.00mg/L, 1.00~10.00mg/L)
      Measurement range 0.02~ 10.00mg/L (divided into 0.02~ 1.00mg/L, 1.00~10.00mg/L two ranges), error of indication ≤ +/- 3%, can achieve high-precision and stable copper concentration measurement.
      Compare
      JINGQI WD8803 Chlorine dioxide Tester
      $481.00 SE
      JINGQI WD8803 Chlorine dioxide Tester
      chlorine dioxide0.05~25.00mg/L
      Measurement range 0.05~ 25.00mg/L, error of indication ≤ +/- 5% FS, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8218 Iodine Tester
      $481.00 SE
      JINGQI WD8218 Iodine Tester
      iodine0.0~0.8mg/L
      Measurement range 0.0~ 0.8mg/L, error of indication ≤ +/- 5%, Optical inspection Stability ≤ 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8202 Manganese Tester
      $481.00 SE
      JINGQI WD8202 Manganese Tester
      manganese0.02~5.00mg/L
      Measurement range 0.02~ 5.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%, can automatically process data and directly display the manganese concentration value of water samples.
      Compare
      JINGQI WD8104 Nitrite Tester
      $481.00 SE
      JINGQI WD8104 Nitrite Tester
      Nitrous acid0.02~5.00mg/L
      Measurement range 0.02~ 5.00mg/L, error of indication ≤ +/- 5%, minimum detection limit 0.01mg/L, large-screen LCD Chinese display, Chinese menu operation
      Compare
      JINGQI WD8213 Antimony Tester
      $481.00 SE
      JINGQI WD8213 Antimony Tester
      antimony0.10~5.00mg/L
      Measurement range 0.10~5.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      TONGAO TR-710H iron meter, water quality heavy metals Detector
      $786.00 SE
      TONGAO TR-710H iron meter, water quality heavy metals Detector
      iron0~50Mg/L (measured in sections)
      Detection of iron content, the range is 0.01mg/L-50mg/L (measured in sections), no digestion is required, the detection time is 15 to 20 minutes, and the digestion Colorimetric integrated detection is used, which conforms to the HJ/T345-2007 standard.
      Compare
      JINGQI WD8216 Silver Tester
      $481.00 SE
      JINGQI WD8216 Silver Tester
      silver0.01~1.00mg/L
      Measurement range 0.01~ 1.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      TONGAO TR-115H Portable Water Quality Permanganate Index (CODmn) Tester
      $786.00 SE
      TONGAO TR-115H Portable Water Quality Permanganate Index (CODmn) Tester
      permanganate index0~10Mg/L (measured in sections)
      The permanganate index (CODmn) was detected, the range was 0.1mg/L-10mg/L (measured in sections), the digestion was carried out in a Water Bath for 13min, and the digestion Colorimetric integrated detection was used, which conformed to the GB11892 standard.
      Compare
      JINGQI WD8215 Lead Tester
      $481.00 SE
      JINGQI WD8215 Lead Tester
      lead0.01~0.50mg/L
      Measurement range 0.01~ 0.50mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      JINGQI WD8103 Nitrate Tester
      $481.00 SE
      JINGQI WD8103 Nitrate Tester
      Nitrate0.02~10.00mg/L
      Measurement range 0.02~ 10.00mg/L, error of indication ≤ +/- 5%, minimum detection limit 0.01mg/L, large-screen LCD Chinese display, Chinese menu operation.
      Compare
      JINGQI WD8210 Barium Tester
      $481.00 SE
      JINGQI WD8210 Barium Tester
      Barium0.06~3.00mg/L
      Measurement range 0.06~ 3.00mg/L, error of indication ≤ +/- 5%, Optical inspection Stability < 0.002A/20min, Repeatability ≤ 3%
      Compare
      If you don't know how to choose "STIP-scan", please consult customer service.
      Focus on online sales of Lab Testing Instruments