      Result > Brand: NiRun Display:Digital display >

      Rotational Viscometer

      15 results
      Featured Hot Price Time
      NIRUN NTV-CAP1HB cone-plate viscometer Low shear rate, rotor required separately
      $8591.00 SE
      NIRUN NTV-CAP1HB cone-plate viscometer Low shear rate, rotor required separately
      10.5~7800000 mPa·s±1%(F.S)
      Rotor speed 0.1~ 250rpm, viscosity range 10.5~ 7800000 mPa · s, Measurement accuracy +/- 1% (F. S), Plate Temperature range -1 ℃~ 150 ℃, temperature accuracy +/- 0.1 ℃, optional rotor CPE-40, CPE-41, CPE-42, CPE-51, CPE-52, Power supply Voltage AC power adapter 100V-240V, temperature sensor PT100 temperature sensor, Interface Gigabit network port.
      Compare
      NIRUN NTV-CAP1LV cone-plate viscometer Low shear rate, rotor required separately
      $8591.00 SE
      NIRUN NTV-CAP1LV cone-plate viscometer Low shear rate, rotor required separately
      0.1~92000 mPa·s±1%(F.S)
      Rotor speed 0.1~ 250rpm, viscosity range 0.1~ 92000 mPa · s, Measurement accuracy +/- 1% (F. S), Plate Temperature range -2 ℃~ 120 ℃, Temperature accuracy +/- 0.1 ℃, optional rotor CPE-40, CPE-41, CPE-42, CPE-51, CPE-52.
      Compare
      NIRUN NTV-AI500 touch high temperature Rotational Viscometer 500 ℃
      $4801.00 SE
      NIRUN NTV-AI500 touch high temperature Rotational Viscometer 500 ℃
      touch type5~1M或50~10MPa.s±1%
      50-10MPa.s, equipped with heating device, temperature control limit 500 ℃, Measurement accuracy +/- 1%, suitable for hot-melt adhesive, asphalt, paraffin, high polymer and other test viscosity values.
      Compare
      NIRUN FTV-E Economic Starch Viscosity-Tester Rotor speed 0.1~ 200rpm
      $5715.00 SE
      NIRUN FTV-E Economic Starch Viscosity-Tester Rotor speed 0.1~ 200rpm
      digital display50~1000000mPa·s±2%10ml
      Digital display, Measurement range 50~1000000mPa · s, rotor specification 1 F1 rotor, Rotor speed 0.1~ 200rpm, reproducibility +/- 1% F.S, Measurement accuracy +/- 2% F.S, Interface RS232, application standard GB/T2 2427.7 - 2 0 0 8, GB/T 2485.3 - 2 0 0, capacity 10ml, Temperature range -1~ 150 ℃.
      Compare
      NIRUN RDV-3 + Pro Digital Viscometer 20~40 million cP Measurement range
      $4627.00 SE
      NIRUN RDV-3 + Pro Digital Viscometer 20~40 million cP Measurement range
      digital display20~40000000mPa·s±1%600Ml beaker or optional small sample adapter300~600ml400 or 800ml (self-provided)
      Digital display, Measurement range 20~40000000mPa · s, Rotor specifications 2 #, 3 #, 4 #, 5 #, 6 #, 7 #(1 #optional), Rotor speed 0.1~ 250rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage 110~220V 50Hz/60Hz, DC17V1.2A, Interface RS232, weight 7kg, capacity 600ml.
      Compare
      NIRUN HADV-3 + Pro Digital Viscometer 40~80 million cP Measurement range
      $4627.00 SE
      NIRUN HADV-3 + Pro Digital Viscometer 40~80 million cP Measurement range
      digital display40~80000000mPa·s±1%600Ml beaker or optional small sample adapter300~600ml400 or 800ml (self-provided)
      Digital display, Measurement range 40~80000000mPa · s, Rotor specifications 2 #, 3 #, 4 #, 5 #, 6 #, 7 #(1 #optional), Rotor speed 0.1~ 750rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S.
      Compare
      NIRUN HBDV-3 + Pro Digital Viscometer 160~32 million cP measuring range
      $4627.00 SE
      NIRUN HBDV-3 + Pro Digital Viscometer 160~32 million cP measuring range
      digital display160~320000000mPa·s±1%400 or 800ml (self-provided)600Ml beaker or optional small sample adapter300~600ml
      Compare
      NIRUN NTV-T1HA Viscosity and temperature control machine 100-6.6 mPa · s
      $4839.00 SE
      NIRUN NTV-T1HA Viscosity and temperature control machine 100-6.6 mPa · s
      touch type100~6.6mPa·s±1%2~16ml
      Measurement range 100~6.6mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232, USB, Operating language Chinese, capacity 2~ 16ml.
      Compare
      NIRUN NTV-T2L Viscosity and Temperature Control Integrated Machine 5-33Mmpa.s
      $5666.00 SE
      NIRUN NTV-T2L Viscosity and Temperature Control Integrated Machine 5-33Mmpa.s
      touch type5~33mmpa.s±1%2~16ml
      Measurement range 5~ 33Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃.
      Compare
      NIRUN NTV-T1L Viscosity and Temperature Control Integrated Machine 5~ 3300000mPa · s
      $4839.00 SE
      NIRUN NTV-T1L Viscosity and Temperature Control Integrated Machine 5~ 3300000mPa · s
      touch type5~3300000mPa·s±1%2~16ml
      Measurement range 5~ 3300000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232, USB, Operating language Chinese, capacity 2~ 16ml.
      Compare
      NIRUN NTV-T1R Viscosity and Temperature Control Integrated Machine 50~3300000mPa · s
      $4839.00 SE
      NIRUN NTV-T1R Viscosity and Temperature Control Integrated Machine 50~3300000mPa · s
      touch type50~3300000mPa·s±1%2~16ml
      Measurement range 50~3300000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S.
      Compare
      NIRUN NTV-T2R Viscosity and temperature control machine 50-3.3 Mmpa.s
      $5666.00 SE
      NIRUN NTV-T2R Viscosity and temperature control machine 50-3.3 Mmpa.s
      touch type50~3.3mmpa.s±1%2~16ml
      Measurement range 50~3.3Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃, software system DV-T2 data collection and drawing software (optional).
      Compare
      NIRUN NTV-T2HB Viscosity and temperature control machine 400-26.4 Mmpa.s
      $5666.00 SE
      NIRUN NTV-T2HB Viscosity and temperature control machine 400-26.4 Mmpa.s
      touch type400~26.4Mpa.s±1%2~16ml
      Measurement range 400~26.4Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃.
      Compare
      NIRUN NTV-T2HA Viscosity and temperature control machine 100-6.6 Mmpa.s
      $5666.00 SE
      NIRUN NTV-T2HA Viscosity and temperature control machine 100-6.6 Mmpa.s
      touch type100~6.6Mpa.s±1%2~16ml
      Measurement range 100~6.6Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃.
      Compare
      NIRUN NTV-T1HB viscosity temperature control machine 400-26.4 mPa · s
      $4839.00 SE
      NIRUN NTV-T1HB viscosity temperature control machine 400-26.4 mPa · s
      touch type400~26.4mPa·s±1%2~16ml
      Measurement range 400~26.4mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232, USB, Operating language Chinese, capacity 2~ 16ml, automatic lifting system.
      Compare
      If you don't know how to choose "Rotational Viscometer", please consult customer service.