$4276.00
SE
NIRUN NTV-T3R Viscosity and Temperature Control Integrated Machine 10 million cp Suitable for molten materials
touch type25-10000000mPa·s±1%FS2~16ml
250 ℃ temperature control, 10 million CP, standard SC4-21, 27, 28, 29 rotor, Measurement accuracy +/- 1%, automatic lifting system, hot-melt adhesive asphalt paraffin and other molten materials

$4276.00
SE
NIRUN NTV-T3L viscosity temperature control machine 1 million CP hot-melt adhesive asphalt paraffin wax and other molten materials
touch type5-1000000mPa·s±1%FS2~16ml
250 ℃ temperature control, 1 million CP, standard SC4-21, 27, 28, 29 rotor, Measurement accuracy +/- 1%, hot-melt adhesive asphalt paraffin and other molten materials

$4276.00
SE
NIRUN NTV-T3HB viscosity and temperature control integrated machine 80 million cp large range, suitable for all kinds of molten materials
touch type200~80000000mPa·s±1%FS2~16ml
80 million cp large range, viscosity temperature control integration, temperature control 250 ℃, hot-melt adhesive, asphalt, paraffin and other molten materials. Standard SC4-21, 27, 28, 29 rotor, 1% Measurement accuracy.

$4276.00
SE
NIRUN NTV-T3HA viscosity temperature control machine 20 million cp 250 ℃ hot-melt adhesive and other molten materials
touch type50-20000000mPa·s±1%FS2~16ml
Touch type, 20 million cp, 250 ℃, standard SC4-21, 27, 28, 29 rotors, Measurement accuracy is +/- 1%. Special for hot-melt adhesives, asphalt, paraffin and other molten materials.

$5666.00
SE
NIRUN NTV-T2L Viscosity and Temperature Control Integrated Machine 5-33Mmpa.s
touch type5~33mmpa.s±1%2~16ml
Measurement range 5~ 33Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃.

$4839.00
SE
NIRUN NTV-T1L Viscosity and Temperature Control Integrated Machine 5~ 3300000mPa · s
touch type5~3300000mPa·s±1%2~16ml
Measurement range 5~ 3300000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232, USB, Operating language Chinese, capacity 2~ 16ml.

$4839.00
SE
NIRUN NTV-T1R Viscosity and Temperature Control Integrated Machine 50~3300000mPa · s
touch type50~3300000mPa·s±1%2~16ml
Measurement range 50~3300000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S.

$5666.00
SE
NIRUN NTV-T2R Viscosity and temperature control machine 50-3.3 Mmpa.s
touch type50~3.3mmpa.s±1%2~16ml
Measurement range 50~3.3Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃, software system DV-T2 data collection and drawing software (optional).

$5666.00
SE
NIRUN NTV-T2HB Viscosity and temperature control machine 400-26.4 Mmpa.s
touch type400~26.4Mpa.s±1%2~16ml
Measurement range 400~26.4Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃.

$5666.00
SE
NIRUN NTV-T2HA Viscosity and temperature control machine 100-6.6 Mmpa.s
touch type100~6.6Mpa.s±1%2~16ml
Measurement range 100~6.6Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃.

$4839.00
SE
NIRUN NTV-T1HB viscosity temperature control machine 400-26.4 mPa · s
touch type400~26.4mPa·s±1%2~16ml
Measurement range 400~26.4mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232, USB, Operating language Chinese, capacity 2~ 16ml, automatic lifting system.

$2092.00
SE
Pingxuan RVTV-2H Brinell Viscometer High Temperature Viscometer 10 million mpas
5~10000000mPa·s± 1% (FS) newtonian fluid
10 million mpas, 1 rotor each of No. 21, 27, 28, and 29 rotor configuration, measurement error ± 1% (FS) newtonian fluid, sexual repeability ± 0.2% (FS) newtonian fluid, Temperature range RT +~ 300 ℃

$954.00
SE
FANGRUI LV-SSR digital display Viscometer for a small number of samples
digital display3~200000mPa·s±2%7~11ml

$1406.00
SE
FANGRUI NDJ-1C Brinell high temperature Rotational Viscometer 250 ℃/20W mPa·s
10~200000mPa·s±2%15~25ml

$1098.00
SE
FANGRUI HB-SSR Digital Rotational Viscometer for small samples
Backlit LCD, digital display400~16000000mPa·s±2%7.8~11.5ml

$989.00
SE
FANGRUI RV-SSR Digital Viscometer for small amounts of samples
Backlit LCD, digital display5~2000000mPa·s±2%7.8~11.5ml

$1027.00
SE
FANGRUI HA-SSR Digital Rotational Viscometer for small samples
Backlit LCD, digital display100~4000000mPa·s±2%7.8~11.5ml

$1470.00
FANGRUI LV-SSR-H Viscometer Coaxial Cylinder Structure, Small Sample Adapter
digital display3 to 1.6 million cP
Measurement accuracy of +/- 2% with a coaxial cylinder structure and a small number of sample adapters, only 7ml sample volume, supports 37 Rotation speed steps and temperature control.

If you don't know how to choose "Rotational Viscometer", please consult customer service.