Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Result > Country: China Sample amout:≤100ml >

      Rotational Viscometer

      49 results
      Featured Hot Price Time
      NIRUN NTV-T3R Viscosity and Temperature Control Integrated Machine 10 million cp Suitable for molten materials
      $4276.00 SE
      NIRUN NTV-T3R Viscosity and Temperature Control Integrated Machine 10 million cp Suitable for molten materials
      touch type25-10000000mPa·s±1%FS2~16ml
      250 ℃ temperature control, 10 million CP, standard SC4-21, 27, 28, 29 rotor, Measurement accuracy +/- 1%, automatic lifting system, hot-melt adhesive asphalt paraffin and other molten materials
      Compare
      NIRUN NTV-T3L viscosity temperature control machine 1 million CP hot-melt adhesive asphalt paraffin wax and other molten materials
      $4276.00 SE
      NIRUN NTV-T3L viscosity temperature control machine 1 million CP hot-melt adhesive asphalt paraffin wax and other molten materials
      touch type5-1000000mPa·s±1%FS2~16ml
      250 ℃ temperature control, 1 million CP, standard SC4-21, 27, 28, 29 rotor, Measurement accuracy +/- 1%, hot-melt adhesive asphalt paraffin and other molten materials
      Compare
      NIRUN NTV-T3HB viscosity and temperature control integrated machine 80 million cp large range, suitable for all kinds of molten materials
      $4276.00 SE
      NIRUN NTV-T3HB viscosity and temperature control integrated machine 80 million cp large range, suitable for all kinds of molten materials
      touch type200~80000000mPa·s±1%FS2~16ml
      80 million cp large range, viscosity temperature control integration, temperature control 250 ℃, hot-melt adhesive, asphalt, paraffin and other molten materials. Standard SC4-21, 27, 28, 29 rotor, 1% Measurement accuracy.
      Compare
      NIRUN NTV-T3HA viscosity temperature control machine 20 million cp 250 ℃ hot-melt adhesive and other molten materials
      $4276.00 SE
      NIRUN NTV-T3HA viscosity temperature control machine 20 million cp 250 ℃ hot-melt adhesive and other molten materials
      touch type50-20000000mPa·s±1%FS2~16ml
      Touch type, 20 million cp, 250 ℃, standard SC4-21, 27, 28, 29 rotors, Measurement accuracy is +/- 1%. Special for hot-melt adhesives, asphalt, paraffin and other molten materials.
      Compare
      NIRUN NTV-T2L Viscosity and Temperature Control Integrated Machine 5-33Mmpa.s
      $5666.00 SE
      NIRUN NTV-T2L Viscosity and Temperature Control Integrated Machine 5-33Mmpa.s
      touch type5~33mmpa.s±1%2~16ml
      Measurement range 5~ 33Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃.
      Compare
      NIRUN NTV-T1L Viscosity and Temperature Control Integrated Machine 5~ 3300000mPa · s
      $4839.00 SE
      NIRUN NTV-T1L Viscosity and Temperature Control Integrated Machine 5~ 3300000mPa · s
      touch type5~3300000mPa·s±1%2~16ml
      Measurement range 5~ 3300000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232, USB, Operating language Chinese, capacity 2~ 16ml.
      Compare
      NIRUN NTV-T1R Viscosity and Temperature Control Integrated Machine 50~3300000mPa · s
      $4839.00 SE
      NIRUN NTV-T1R Viscosity and Temperature Control Integrated Machine 50~3300000mPa · s
      touch type50~3300000mPa·s±1%2~16ml
      Measurement range 50~3300000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S.
      Compare
      NIRUN NTV-T2R Viscosity and temperature control machine 50-3.3 Mmpa.s
      $5666.00 SE
      NIRUN NTV-T2R Viscosity and temperature control machine 50-3.3 Mmpa.s
      touch type50~3.3mmpa.s±1%2~16ml
      Measurement range 50~3.3Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃, software system DV-T2 data collection and drawing software (optional).
      Compare
      NIRUN NTV-T2HB Viscosity and temperature control machine 400-26.4 Mmpa.s
      $5666.00 SE
      NIRUN NTV-T2HB Viscosity and temperature control machine 400-26.4 Mmpa.s
      touch type400~26.4Mpa.s±1%2~16ml
      Measurement range 400~26.4Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃.
      Compare
      NIRUN NTV-T2HA Viscosity and temperature control machine 100-6.6 Mmpa.s
      $5666.00 SE
      NIRUN NTV-T2HA Viscosity and temperature control machine 100-6.6 Mmpa.s
      touch type100~6.6Mpa.s±1%2~16ml
      Measurement range 100~6.6Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃.
      Compare
      NIRUN NTV-T1HB viscosity temperature control machine 400-26.4 mPa · s
      $4839.00 SE
      NIRUN NTV-T1HB viscosity temperature control machine 400-26.4 mPa · s
      touch type400~26.4mPa·s±1%2~16ml
      Measurement range 400~26.4mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232, USB, Operating language Chinese, capacity 2~ 16ml, automatic lifting system.
      Compare
      Pingxuan NDJ-79 dial Rotational Viscometer
      $444.00 SE
      Pingxuan NDJ-79 dial Rotational Viscometer
      dial type1~1000000mpa.s15~70ml
      Compare
      Pingxuan RVTV-2H Brinell Viscometer High Temperature Viscometer 10 million mpas
      $2092.00 SE
      Pingxuan RVTV-2H Brinell Viscometer High Temperature Viscometer 10 million mpas
      5~10000000mPa·s± 1% (FS) newtonian fluid
      10 million mpas, 1 rotor each of No. 21, 27, 28, and 29 rotor configuration, measurement error ± 1% (FS) newtonian fluid, sexual repeability ± 0.2% (FS) newtonian fluid, Temperature range RT +~ 300 ℃
      Compare
      FANGRUI LV-SSR digital display Viscometer for a small number of samples
      $954.00 SE
      FANGRUI LV-SSR digital display Viscometer for a small number of samples
      digital display3~200000mPa·s±2%7~11ml
      Compare
      FANGRUI HB-SSR Digital Rotational Viscometer for small samples
      $1098.00 SE
      FANGRUI HB-SSR Digital Rotational Viscometer for small samples
      Backlit LCD, digital display400~16000000mPa·s±2%7.8~11.5ml
      Compare
      FANGRUI RV-SSR Digital Viscometer for small amounts of samples
      $989.00 SE
      FANGRUI RV-SSR Digital Viscometer for small amounts of samples
      Backlit LCD, digital display5~2000000mPa·s±2%7.8~11.5ml
      Compare
      FANGRUI HA-SSR Digital Rotational Viscometer for small samples
      $1027.00 SE
      FANGRUI HA-SSR Digital Rotational Viscometer for small samples
      Backlit LCD, digital display100~4000000mPa·s±2%7.8~11.5ml
      Compare
      FANGRUI LV-SSR-H Viscometer Coaxial Cylinder Structure, Small Sample Adapter
      $1470.00
      FANGRUI LV-SSR-H Viscometer Coaxial Cylinder Structure, Small Sample Adapter
      digital display3 to 1.6 million cP
      Measurement accuracy of +/- 2% with a coaxial cylinder structure and a small number of sample adapters, only 7ml sample volume, supports 37 Rotation speed steps and temperature control.
      Compare
      If you don't know how to choose "Rotational Viscometer", please consult customer service.
      Focus on online sales of Lab Testing Instruments