Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Result > Country: China Type:Thermal Controlled >

      Rotational Viscometer

      12 results
      Featured Hot Price Time
      NIRUN NTV-T1HA Viscosity and temperature control machine 100-6.6 mPa · s
      $4839.00 SE
      NIRUN NTV-T1HA Viscosity and temperature control machine 100-6.6 mPa · s
      touch type100~6.6mPa·s±1%2~16ml
      Measurement range 100~6.6mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232, USB, Operating language Chinese, capacity 2~ 16ml.
      Compare
      NIRUN NTV-T3R Viscosity and Temperature Control Integrated Machine 10 million cp Suitable for molten materials
      $4276.00 SE
      NIRUN NTV-T3R Viscosity and Temperature Control Integrated Machine 10 million cp Suitable for molten materials
      touch type25-10000000mPa·s±1%FS2~16ml
      250 ℃ temperature control, 10 million CP, standard SC4-21, 27, 28, 29 rotor, Measurement accuracy +/- 1%, automatic lifting system, hot-melt adhesive asphalt paraffin and other molten materials
      Compare
      NIRUN NTV-T3L viscosity temperature control machine 1 million CP hot-melt adhesive asphalt paraffin wax and other molten materials
      $4276.00 SE
      NIRUN NTV-T3L viscosity temperature control machine 1 million CP hot-melt adhesive asphalt paraffin wax and other molten materials
      touch type5-1000000mPa·s±1%FS2~16ml
      250 ℃ temperature control, 1 million CP, standard SC4-21, 27, 28, 29 rotor, Measurement accuracy +/- 1%, hot-melt adhesive asphalt paraffin and other molten materials
      Compare
      NIRUN NTV-T3HB viscosity and temperature control integrated machine 80 million cp large range, suitable for all kinds of molten materials
      $4276.00 SE
      NIRUN NTV-T3HB viscosity and temperature control integrated machine 80 million cp large range, suitable for all kinds of molten materials
      touch type200~80000000mPa·s±1%FS2~16ml
      80 million cp large range, viscosity temperature control integration, temperature control 250 ℃, hot-melt adhesive, asphalt, paraffin and other molten materials. Standard SC4-21, 27, 28, 29 rotor, 1% Measurement accuracy.
      Compare
      NIRUN NTV-T3HA viscosity temperature control machine 20 million cp 250 ℃ hot-melt adhesive and other molten materials
      $4276.00 SE
      NIRUN NTV-T3HA viscosity temperature control machine 20 million cp 250 ℃ hot-melt adhesive and other molten materials
      touch type50-20000000mPa·s±1%FS2~16ml
      Touch type, 20 million cp, 250 ℃, standard SC4-21, 27, 28, 29 rotors, Measurement accuracy is +/- 1%. Special for hot-melt adhesives, asphalt, paraffin and other molten materials.
      Compare
      NIRUN NTV-T2L Viscosity and Temperature Control Integrated Machine 5-33Mmpa.s
      $5666.00 SE
      NIRUN NTV-T2L Viscosity and Temperature Control Integrated Machine 5-33Mmpa.s
      touch type5~33mmpa.s±1%2~16ml
      Measurement range 5~ 33Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃.
      Compare
      NIRUN NTV-T1L Viscosity and Temperature Control Integrated Machine 5~ 3300000mPa · s
      $4839.00 SE
      NIRUN NTV-T1L Viscosity and Temperature Control Integrated Machine 5~ 3300000mPa · s
      touch type5~3300000mPa·s±1%2~16ml
      Measurement range 5~ 3300000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232, USB, Operating language Chinese, capacity 2~ 16ml.
      Compare
      NIRUN NTV-T1R Viscosity and Temperature Control Integrated Machine 50~3300000mPa · s
      $4839.00 SE
      NIRUN NTV-T1R Viscosity and Temperature Control Integrated Machine 50~3300000mPa · s
      touch type50~3300000mPa·s±1%2~16ml
      Measurement range 50~3300000mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S.
      Compare
      NIRUN NTV-T2R Viscosity and temperature control machine 50-3.3 Mmpa.s
      $5666.00 SE
      NIRUN NTV-T2R Viscosity and temperature control machine 50-3.3 Mmpa.s
      touch type50~3.3mmpa.s±1%2~16ml
      Measurement range 50~3.3Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃, software system DV-T2 data collection and drawing software (optional).
      Compare
      NIRUN NTV-T2HB Viscosity and temperature control machine 400-26.4 Mmpa.s
      $5666.00 SE
      NIRUN NTV-T2HB Viscosity and temperature control machine 400-26.4 Mmpa.s
      touch type400~26.4Mpa.s±1%2~16ml
      Measurement range 400~26.4Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃.
      Compare
      NIRUN NTV-T2HA Viscosity and temperature control machine 100-6.6 Mmpa.s
      $5666.00 SE
      NIRUN NTV-T2HA Viscosity and temperature control machine 100-6.6 Mmpa.s
      touch type100~6.6Mpa.s±1%2~16ml
      Measurement range 100~6.6Mmpa.s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.1~ 200rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232-USB interface, Operating language Chinese, capacity 2~ 16ml, lifting system automatic lifting system, Temperature range - 1~ 150 ℃, temperature accuracy +/- 0.1 ℃.
      Compare
      NIRUN NTV-T1HB viscosity temperature control machine 400-26.4 mPa · s
      $4839.00 SE
      NIRUN NTV-T1HB viscosity temperature control machine 400-26.4 mPa · s
      touch type400~26.4mPa·s±1%2~16ml
      Measurement range 400~26.4mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232, USB, Operating language Chinese, capacity 2~ 16ml, automatic lifting system.
      Compare
      If you don't know how to choose "Rotational Viscometer", please consult customer service.
      Focus on online sales of Lab Testing Instruments