$13411.00
SE
ZKHS QL-225 ozone aging test chamber ozone aging test chamber
RT+10~70℃、 0~70℃65~98%R.H、40~98%R.H(Low concentration) 10~1000PPhm, (high concentration) 1~ 500PPm, Fluctuation ± 10%
Inner chamber dimensions 500x600x750mm, temperature RT + 10~ 70 ℃ or 0~ 70 ℃, Humidity 65~ 98% R.H or 40~ 98% R.H, ozone concentration low 10~ 1000PPhm high 1~ 500PPm, Temperature Fluctuation +/- 0.5 ℃, Humidity stability + 2-3% R.H, Rack Rotation speed 1rpm, Gas Flow velocity 12~ 16mm/S, silent discharge tubular ozone generator.

$13329.00
SE
HZAOC QL-500 ozone aging test chamber
RT+10~80°C≤65%R.H10 ~ 1000pphm
Ozone concentration 10~ 1000pphm, temperature RT + 10~ 80 ℃, Humidity ≤ 65% R.H, Temperature Fluctuation +/- 0.5 ℃, Temperature Uniformity ≤ +/- 2 ℃, 7 inch true color LCD Touchscreen control, continuous PID control, power failure recovery function, high voltage silent discharge tube type.

$5989.00
SE
CHINA NBC-CY150L Ozone Aging Test Chamber 150L
RT+ 10~80 ℃ (Miscellaneous temperature and Humidity requirements need to be purchased)
The content of ozone in the atmosphere is very small is the main factor of rubber checking, this product simulates and strengthens the ozone conditions in the atmosphere, studies the effect of ozone on rubber, and quickly identifies and evaluates the anti-ozone aging performance of rubber and the protective effect of anti-ozone agents.

$11543.00
SE
ZKHS QL-100 Ozone aging test chamber Illuminant aging test
RT+10~70℃、 0~70℃65~98%R.H、40~98%R.H(Low concentration) 10~1000PPhm, (high concentration) 1~ 500PPm, Fluctuation? 10%
Inner chamber dimensions 450X450X500mm, Temperature range RT + 10~ 70 ℃/0~ 70 ℃, Humidity 65~ 98% R.H, Ozone concentration 10~ 1000PPhm or 1~ 500PPm, Temperature Fluctuation +/- 0.5 ℃, Rotation speed 1rpm, independent control of light can be alternately cycled, time setting 0~ 9999M/H.

$12199.00
SE
ZKHS QL-150 ozone aging test chamber ozone aging test chamber
RT+10~70℃、 0~70℃65~98%R.H、40~98%R.H(Low concentration) 10~1000PPhm, (high concentration) 1~ 500PPm, Fluctuation ± 10%
Inner chamber dimensions 500 * 500 * 600mm, Temperature range RT + 10~ 70 ℃, 0~ 70 ℃, Humidity range 65~ 98% R.H, 40~ 98% R.H, ozone concentration 10~ 1000PPhm, 1~ 500PPm, Temperature Fluctuation +/- 0.5 ℃, Humidity stability + 2, - 3% R.H, 360 degree swirl/spin sample holder, Gas Flow velocity 12~ 16mm/S, Silent discharge tubular ozone generator, Safety protection such as leakage and overtemperature.

$14640.00
SE
ZKHS QL-500 ozone aging test chamber ozone aging test chamber
65~98%R.H、40~98%R.H(Low concentration) 10~1000PPhm, (high concentration) 1~ 500PPm, Fluctuation ± 10%RT+10~70℃、 0~70℃
Inner chamber dimensions 700 × 800 × 900mm, Temperature range RT + 10~ 70 ℃ or 0~ 70 ℃, Humidity 65~ 98% R.H or 40~ 98% R.H, Ozone concentration 10~ 1000PPhm or 1~ 500PPm, Temperature Fluctuation +/- 0.5 ℃, 360 degree swirl/spin sample holder.

$16262.00
SE
ZKHS QL-010 Ozone Aging Test Chamber ozone aging machine
RT+10~70℃、 0~70℃65~98%R.H、40~98%R.H(Low concentration) 10~1000PPhm, (high concentration) 1~ 500PPm, Fluctuation ± 10%

Login
HUANGYI HYQL-150 ozone aging test chamber 100~ 1000pphm
20~+65℃30~95%R.H25-1000Pphm adjustable
500 * 600 * 500Mm, 20~ + 65 ℃, 30~ 95% R. H, 25-1000pphm adjustable, +/- 2pphm, mixed aging test under static tensile deformation, continuous online detection of ozone concentration.

$11248.00
SE
HZAOC QL-150 ozone aging test chamber
≤65%R.H10 ~ 1000pphmRT+10~80°C
Ozone concentration range 10~ 1000pphm, concentration deviation ≤ 10%, Temperature range RT + 10~ 80 ℃, Humidity ≤ 65% R.H, 7 inch true color LCD Touchscreen controller, with fixed value and program operation, continuous PID control, power failure recovery function

$10806.00
SE
HZAOC QL-100 ozone aging test chamber
RT+10~80°C≤65%R.H10 ~ 1000pphm
Ozone concentration range 10~ 1000pphm, Temperature range RT + 10~ 80 ℃, 7 inch true color LCD Touchscreen controller, independent ozone concentration controller, PID control, power failure recovery setting, a variety of alarm functions.

If you don't know how to choose "Ozone aging chamber", please consult customer service.