$628.00
KORNO GT903-BL-O3 portable ozone Detector, detection range 0.001-5ppm
Ozone (O3)0.001-5ppmPump suction type, air pump flow rate: 500-1000mL/min adjustable (30-level fine-tuning), can work in a micro-negative pressure environment
Temperature detection range: -40~120 ℃, humidity detection range: 0-100% RH, resolution 0.001ppm, detection gas ozone (O3), detection accuracy ≤ +/- 3% F.S, detection range 0.001-5ppm, detection principle imported electrochemistry, detection method pump suction

$732.00
SE
Empaer AATL-O2 (Pump Suction) Pathfinder Series Fixed Oxygen Detector
O20~30%VOLDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias O2, detection range 0-30% VOL, error of indication 1%, Repeatability 3% FS, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Response time T90 ≤ national standard

$1305.00
SE
Empaer AATL-CO2 (Pump Suction) Pathfinder Series Stationary Carbon Dioxide Detector
CO20~5000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CO2, detection range 0~5000ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$806.00
SE
Empaer AATL-CL2 (Pump Suction) Pathfinder Series Fixed Chlorine Detector
CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CL2, detection range 0~50ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$682.00
SE
Empaer AATL-CH4 (Pump Suction) Pathfinder Series Fixed Methane Detector
CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CH4, detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$705.00
SE
Empaer AATL-CO (Pump Suction) Pathfinder Series Stationary Carbon Monoxide Detectors
CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CO, detection range 0-1000ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$705.00
SE
Empaer AATL-H2S (pump suction) pathfinder series stationary hydrogen sulfide Detector
H2S0~500ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias H2S, detection range 0-500ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$721.00
SE
Empaer AATL-H2 (Pump Suction) Pathfinder Series Fixed Hydrogen Detector
H20~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias H2, detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$1034.00
SE
Empaer AATL-SO2 (Pump Suction) Pathfinder Series Stationary Sulfur Dioxide Detector
SO20~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias SO2, detection range 0~100ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation)

$1034.00
SE
Empaer AATL-O3 (Pump Suction) Pathfinder Series Fixed Ozone Detector
O30~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias O3, detection range 0~100ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$682.00
SE
Empaer AATL-EX (Pump Suction) Pathfinder Series Fixed Gas Detector
EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias EX, detection range 0-100% LEL, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

If you don't know how to choose "Gas detector", please consult customer service.