$638.00
SE
Empaer AATL-SO2 (sound and light alarm) Pathfinder series fixed sulfur dioxide Detector
SO20~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, please consult the customer service of the mall.
Gas name and alias SO2, detection range 0~100ppm, sound and light alarm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation)

$673.00
SE
Empaer AATL-EX (Pump Suction) Pathfinder Series Fixed Gas Detector
EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias EX, detection range 0-100% LEL, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

If you don't know how to choose "Gas detector", please consult customer service.