Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Result > Country: China Number of Gases:Single gas >

      Gas detector

      123 results
      Featured Hot Price Time
      GUOYUGRA GY/VGD-200-NH3-G (0-100ppm) ammonia Gas Detector
      $257.00 SE
      GUOYUGRA GY/VGD-200-NH3-G (0-100ppm) ammonia Gas Detector
      NH30-100Ppm (optional 1000ppm)diffusion
      Leak detection, not suitable for long-term ammonia occasions, using high Sensitivity intelligent sensing technology, support custom range and a variety of Output signals, wireless modules (such as 4G, LORA) to achieve remote data transmission.
      Compare
      KORNO MOT500-O2-Y oxygen Detector, range 0-30% Vol
      $305.00 SE
      KORNO MOT500-O2-Y oxygen Detector, range 0-30% Vol
      Oxygen O20~30%volDiffusion, flow, pump suction optional
      O2, range 0~30% vol, resolution 0.01% vol, Response time T90 ≤ 20s, Linearity ≤ +/- 1%, detection accuracy ≤ +/- 3%, explosion-proof mark CNEx16.0547, Protection level IP65
      Compare
      SMART SENSOR AR8500 Ammonia Gas Detector, range 0~100ppm
      $316.00 SE
      SMART SENSOR AR8500 Ammonia Gas Detector, range 0~100ppm
      Ammonia NH30~100ppm
      NH3, range 0~100ppm, resolution 0.1ppm, intrinsic error +/- 2%, response time T90 ≤ 120s, recovery time ≤ 120s, alarm mode sound and light
      Compare
      SMART SENSOR AR8600L Formaldehyde Detector measurement range 0~5PPM
      $340.00 SE
      SMART SENSOR AR8600L Formaldehyde Detector measurement range 0~5PPM
      ElectrochemistryFormaldehyde CH2O0~5ppm
      Formaldehyde CH2O, range 0~5ppm, resolution 0.01ppm, Sensors principle electrochemistry, intrinsic error +/- 10%
      Compare
      KORNO MOT500-H2S-Y Online hydrogen sulfide alarm instrument 0-50ppm
      $287.00 SE
      KORNO MOT500-H2S-Y Online hydrogen sulfide alarm instrument 0-50ppm
      H2S0~50ppmDiffusion, flow, pump suction optional
      H2S, range 0~50ppm, resolution 0.01ppm, Response time T90 ≤ 20s, Linearity ≤ +/- 1%, detection accuracy ≤ +/- 3%, explosion-proof mark CNEx16.0547, Protection level IP65
      Compare
      SMART SENSOR AR8200 carbon dioxide Detector measurement range: 350~9999PPM
      $280.00 SE
      SMART SENSOR AR8200 carbon dioxide Detector measurement range: 350~9999PPM
      CO2350~9999ppm
      CO2, range 350~9999ppm, resolution 5ppm, intrinsic error +/- (30PPM + 5% reading), response time~ 90s, recovery time < 120s, alarm mode sound and light
      Compare
      HONEYEAGLE HNAG1000-H2S Fixed hydrogen sulfide Detector 0-500PPM
      $285.00 SE
      HONEYEAGLE HNAG1000-H2S Fixed hydrogen sulfide Detector 0-500PPM
      atmospheric monitoringH2S0~500ppmDiffusion
      Compare
      KORNO GT-903-H2S-Y Pump suction hydrogen sulfide Detector 0-50ppm
      $270.00 SE
      KORNO GT-903-H2S-Y Pump suction hydrogen sulfide Detector 0-50ppm
      ElectrochemistryHydrogen sulfide H2Shydrogen sulfide0~50ppmPump suctionPump suction
      Electrochemical sensor principle, pump suction sampling, detection of hydrogen sulfide gas, range 0-50ppm, through explosion-proof certification, with Filter, sound and light alarm, detection accuracy ≤ +/- 3%.
      Compare
      KORNO GT-903-O2-Y Pump Suction Oxygen Detector, Range 0-30% Vol
      $287.00 SE
      KORNO GT-903-O2-Y Pump Suction Oxygen Detector, Range 0-30% Vol
      Oxygen O20 ~ 30% volPump suction
      Detect oxygen concentration, dust-proof design and water gas filtrate, equipped with dust Filter, built-in micro air pump, original imported high-precision Sensors, full software Automatic calibration, range 0-30% Vol.
      Compare
      HONEYEAGLE HNAG1000-CO Fixed Carbon Monoxide Detector 1500PPM
      $285.00 SE
      HONEYEAGLE HNAG1000-CO Fixed Carbon Monoxide Detector 1500PPM
      ElectrochemistryCO0~1500ppmDiffusion
      Compare
      HONEYEAGLE HNAG1000-H2S Fixed hydrogen sulfide Detector 0-2000PPM
      $347.00 SE
      HONEYEAGLE HNAG1000-H2S Fixed hydrogen sulfide Detector 0-2000PPM
      ElectrochemistryH2S0~2000ppmDiffusion
      Compare
      HONEYEAGLE HNAG1000-CO Fixed Carbon Monoxide Detector 500PPM
      $285.00 SE
      HONEYEAGLE HNAG1000-CO Fixed Carbon Monoxide Detector 500PPM
      ElectrochemistryCO0~500ppmDiffusion
      Compare
      HONEYEAGLE HNAG1000-H2S Fixed hydrogen sulfide Detector 0-100PPM
      $285.00 SE
      HONEYEAGLE HNAG1000-H2S Fixed hydrogen sulfide Detector 0-100PPM
      atmospheric monitoringH2S0~100ppmDiffusion
      Compare
      HONEYEAGLE HNAG1000-H2S Fixed hydrogen sulfide Detector 0-1000PPM
      $347.00 SE
      HONEYEAGLE HNAG1000-H2S Fixed hydrogen sulfide Detector 0-1000PPM
      ElectrochemistryH2S0~1000ppmDiffusion
      Compare
      GUOYUGRA GY/VGD-200-CH2O-G (0-10ppm) Formaldehyde Detector
      $257.00 SE
      GUOYUGRA GY/VGD-200-CH2O-G (0-10ppm) Formaldehyde Detector
      CH2O0-10Pm (optional 50ppm, 100ppm, 200ppm)diffusion
      Intelligent Sensors and MCU chip design, support 4-20mA, RS485, switch and other signal output, equipped with high definition LCD display, support Chinese and English Operating interface.
      Compare
      Smart Sensor ST8100 five-year life oxygen Detector 0~25% VOL
      $260.00 SE
      Smart Sensor ST8100 five-year life oxygen Detector 0~25% VOL
      Principles of ElectrochemistryOxygen (O ³)0 ~ 25% VOL
      Oxygen range 0~25% VOL, measurement accuracy ± 2% FS, using natural diffusion detection, with high limit and low limit sound, light and alarm.
      Compare
      HONEYEAGLE HNAG1000-CO Fixed Carbon Monoxide Detector 2000PPM
      $347.00 SE
      HONEYEAGLE HNAG1000-CO Fixed Carbon Monoxide Detector 2000PPM
      ElectrochemistryCO0~2000ppmDiffusion
      Compare
      HUIRUIPU HRP-T1000-NH3 Ammonia Gas Detector (LCD display with lamp)
      $231.00 SE
      HUIRUIPU HRP-T1000-NH3 Ammonia Gas Detector (LCD display with lamp)
      ElectrochemistryAmmonia NH350ppmDiffusion
      Compare
      GUOYUGRA GY/VGD-200-OUT-G odor Detector, measuring range 0~5ppm
      $344.00 SE
      GUOYUGRA GY/VGD-200-OUT-G odor Detector, measuring range 0~5ppm
      stink0~5ppmdiffusion
      Detect odor concentration, the range is 0~5ppm, Electrochemical sensor principle, suitable for garbage stations, sewage treatment stations, public toilets and other air detection.
      Compare
      HUIRUIPU HRP-T1000-CL2 chlorine Gas Detector (LCD display with lamp)
      $231.00 SE
      HUIRUIPU HRP-T1000-CL2 chlorine Gas Detector (LCD display with lamp)
      ElectrochemistryCL250ppmDiffusion
      Compare
      GUOYUGRA GY/VGD-200-C6H6-G (0-10ppm) benzene Detector
      $319.00 SE
      GUOYUGRA GY/VGD-200-C6H6-G (0-10ppm) benzene Detector
      C6H60-10Pm (optional 50ppm, 100ppm, 1000ppm)diffusion
      Leak detection, accuracy requirements are not high occasions, detection range of 0-10ppm (can be customized), resolution of 0.01ppm, accuracy error ≤ +/- 3%, Response time ≤ 30 seconds, explosion-proof aluminum alloy shell durable.
      Compare
      GUOYUGRA GY/VGD-200-C7H8-G (0-10ppm) toluene Detector
      $319.00 SE
      GUOYUGRA GY/VGD-200-C7H8-G (0-10ppm) toluene Detector
      C7H80-10Pm (optional 50ppm, 100ppm, 1000ppm)diffusion
      Measure leakage, where accuracy is not high, High Sensitivity Intelligent Sensors and MCU chip design, support detection range 0-10ppm (customizable), support remote monitoring and historical data viewing.
      Compare
      GUOYUGRA GY/VGD-200-C8H10-G Xylene Detector 0-10ppm
      $319.00 SE
      GUOYUGRA GY/VGD-200-C8H10-G Xylene Detector 0-10ppm
      Xylene C8H100-10Pm (optional 50, 100, 1000ppm)diffusion
      Detect the leakage of Xylene gas, suitable for occasions with low accuracy requirements, the detection range is 0-10ppm, the detection error is ≤ +/- 3% F. S, and the electrochemistry detection principle is adopted.
      Compare
      GUOYUGRA GY/VGD-200-TVOC-G (0-10ppm) TVOC Detector
      $319.00 SE
      GUOYUGRA GY/VGD-200-TVOC-G (0-10ppm) TVOC Detector
      TVOC0-10Pm (optional 50ppm, 100ppm, 1000ppm)diffusion
      Leak detection, where accuracy requirements are not high, high Sensitivity Intelligent Sensors and low power consumption MCU chip design, support a variety of signal output (4-20mA, RS485, wireless communication, etc.), integrated into industrial control systems or remote monitoring.
      Compare
      GUOYUGRA GY/VGD-200-VOC-G (0-10ppm) VOC Detector
      $319.00 SE
      GUOYUGRA GY/VGD-200-VOC-G (0-10ppm) VOC Detector
      VOC0-10Pm (optional 50ppm, 100ppm, 1000ppm)diffusion
      Leak detection, accuracy requirements are not high occasions, high-precision MCU chip, equipped with high definition LCD screen and Chinese and English switching interface, aluminum alloy explosion-proof shell is sturdy and durable, free cover remote control to achieve zero adjustment and calibrate.
      Compare
      GUOYUGRA GY/VGD-200-ETO-G (0-10ppm) ethylene oxide Detector
      $257.00 SE
      GUOYUGRA GY/VGD-200-ETO-G (0-10ppm) ethylene oxide Detector
      ETO0-10ppm(50ppm、100ppm、500ppm、1000ppm)diffusion
      Electrochemistry, the equipment supports 4-20mA, RS485 and switching signal output, adopts intelligent Sensors and MCU chips, and optional wireless signal transmission modules (such as LORA, 4G, WiFi, etc.).
      Compare
      GUOYUGRA GY/VGD-200-Ex-G (0-5% LEL) Combustible Gas Detector (IR)
      $319.00 SE
      GUOYUGRA GY/VGD-200-Ex-G (0-5% LEL) Combustible Gas Detector (IR)
      Ex0-5% Vol (optional 50% Vol, 100% Vol, 100% LEL)diffusion
      Conventional infrared, 3% accuracy, Sensors life of 5 years, advanced infrared NDIR technology and intelligent MCU chip, aluminum alloy flameproof housing is rugged and durable, infrared remote control operation.
      Compare
      GUOYUGRA GY/VGD-200-NO2-G (0-20ppm) nitrogen dioxide Detector
      $270.00 SE
      GUOYUGRA GY/VGD-200-NO2-G (0-20ppm) nitrogen dioxide Detector
      NO20-20ppm (optional 50ppm, 100ppm)diffusion
      Ordinary performance, leak measurement, can not be used for flue gas environment, using intelligent Sensors technology, support a variety of signal output methods (such as 4-20mA, RS485, switch, etc.), remote monitoring data.
      Compare
      GUOYUGRA GY/VGD-200-HCN-G (0-10ppm) hydrogen cyanide Detector
      $270.00 SE
      GUOYUGRA GY/VGD-200-HCN-G (0-10ppm) hydrogen cyanide Detector
      HCN 0-10Pm (optional 30ppm, 100ppm)diffusion
      Intelligent Sensors and MCU chip design, with a variety of signal output interfaces (such as 4-20mA, RS485, switch), suitable for integration with industrial Control systems such as PLC and DCS, and support wireless transmission.
      Compare
      GUOYUGRA GY/VGD-200-CH4-G (0-5% Vol) Methane Detector (Infrared)
      $319.00 SE
      GUOYUGRA GY/VGD-200-CH4-G (0-5% Vol) Methane Detector (Infrared)
      CH40-5% Vol (optional 50% Vol, 100% Vol, 100% LEL)diffusion
      Conventional infrared, 3% accuracy, Sensors life of 5 years, advanced infrared NDIR detection principle, equipped with low power MCU chip and a variety of signal output, support remote data monitoring and System integration.
      Compare
      If you don't know how to choose "Gas detector", please consult customer service.
      Focus on online sales of Lab Testing Instruments