Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Result > Country: China Sampling Mode:Diffusion >

      Gas detector

      GUOYUGRA GY/VGD-200-CLO2-G (0-1.00 ppm) chlorine dioxide Detector
      $270.00 SE
      GUOYUGRA GY/VGD-200-CLO2-G (0-1.00 ppm) chlorine dioxide Detector
      CLO20-1.00 ppm (optional 10ppm, 50ppm, 200ppm)diffusion
      0-1.00 ppm accurate Measurement range, using MCU chip and intelligent Sensors technology, support a variety of signal output mode, built-in sound and light alarm and remote muffler function.
      Compare
      GUOYUGRA GY/VGD-200-O3-G (0-10.00 ppm) ozone Detector
      $257.00 SE
      GUOYUGRA GY/VGD-200-O3-G (0-10.00 ppm) ozone Detector
      O30-10.00 ppm (optional 20ppm, 50ppm, 100ppm)diffusion
      MCU chip and intelligent Sensors technology, the device supports 4-20mA, RS485, switch and other signal output, optional wireless transmission module (such as LORA, 4G, WiFi, etc.) for remote monitoring.
      Compare
      GUOYUGRA GY/VGD-200-Ex-G (0-100% LEL) Explosion-proof, combustible Gas Detector
      $245.00 SE
      GUOYUGRA GY/VGD-200-Ex-G (0-100% LEL) Explosion-proof, combustible Gas Detector
      Ex0-100%LEL、5%Voldiffusion
      Explosion-proof industrial-grade catalytic combustion Sensors, anti-sulfide and silicon poisoning, anti-over-range Impact, acetylene flammable, intelligent MCU chip and high-sensitivity Sensors, explosion-proof aluminum alloy housing is sturdy and durable.
      Compare
      GUOYUGRA GY/VGD-200-H2-G (0-100ppm) Hydrogen Detector
      $257.00 SE
      GUOYUGRA GY/VGD-200-H2-G (0-100ppm) Hydrogen Detector
      H20-100Pm (optional 500ppm, 1000ppm, 2000ppm, 40000ppm)diffusion
      Leak detection, not suitable for long-term hydrogen occasions, using MCU chips and intelligent Sensors technology, with LCDTFT high definition display, sound and light alarm, remote monitoring and infrared remote control silencing function.
      Compare
      GUOYUGRA GY/VGD-200-HCL-G (0-10ppm) Hydrogen Chloride Detector
      $270.00 SE
      GUOYUGRA GY/VGD-200-HCL-G (0-10ppm) Hydrogen Chloride Detector
      HCL0-10Pm (optional 20ppm, 50ppm, 100ppm, 200ppm)diffusion
      High-precision intelligent Sensors and MCU chip design, with a variety of signal output mode (4-20mA, RS485, switch), support wireless transmission, support remote data transmission and alarm function.
      Compare
      GUOYUGRA GY/VGD-200-NOX-G (0-20ppm) nitrogen oxide Detector
      $270.00 SE
      GUOYUGRA GY/VGD-200-NOX-G (0-20ppm) nitrogen oxide Detector
      NOX0-20Pm (optional 50ppm, 100ppm, 200ppm)diffusion
      Leak detection, can not be used in the flue gas environment, only NO or NO2, using intelligent Sensors and MCU chip technology, support 4-20mA, RS485 and other signal output methods, with explosion-proof design.
      Compare
      GUOYUGRA GY/VGD-200-PH3-G (0-5ppm) phosphating hydrogen Detector
      $270.00 SE
      GUOYUGRA GY/VGD-200-PH3-G (0-5ppm) phosphating hydrogen Detector
      PH30-5 ppm (optional 20ppm, 50ppm, 100ppm)diffusion
      Using advanced catalytic combustion detection principle, with low-power MCU chip and intelligent Sensors, support a variety of signal output methods, in line with strict explosion-proof standards.
      Compare
      GUOYUGRA GY/VGD-200-CL2-G (0-10ppm) Chlorine Detector
      $257.00 SE
      GUOYUGRA GY/VGD-200-CL2-G (0-10ppm) Chlorine Detector
      CL20-10Pm (optional 20ppm, 50ppm, 200ppm)diffusion
      Using advanced catalytic combustion detection principle, with high Sensitivity and accuracy, suitable for chlorine leakage monitoring in industrial environments, easy to connect with PLC, DCS and other Control systems.
      Compare
      GUOYUGRA GY/VGD-200-SO2-G (0-20ppm) sulfur dioxide Detector
      $257.00 SE
      GUOYUGRA GY/VGD-200-SO2-G (0-20ppm) sulfur dioxide Detector
      SO20-20ppm (optional 50ppm, 100ppm)diffusion
      Leak detection, can not be used in the flue gas environment, intelligent Sensors and MCU chips, support a variety of signal output methods, but also support wireless data transmission (such as LORA, 4G, WiFi, etc.).
      Compare
      GUOYUGRA GY/VGD-200-Ex-G (0-100% LEL) High Temperature Combustible Gas Detector
      $369.00 SE
      GUOYUGRA GY/VGD-200-Ex-G (0-100% LEL) High Temperature Combustible Gas Detector
      Ex0-100%LEL、5%Voldiffusion
      High temperature within 260 degrees, Anti-Impact poisoning, catalytic combustion detection principle and intelligent MCU chip, Sensors life of 2 to 3 years, high definition LCD LCD screen, Chinese and English interface switching and remote control adjustment function.
      Compare
      GUOYUGRA GY/VGD-200-NO-G (0-20ppm) nitric oxide Detector
      $270.00 SE
      GUOYUGRA GY/VGD-200-NO-G (0-20ppm) nitric oxide Detector
      NO0-20Pm (optional 50ppm, 100ppm, 250ppm)diffusion
      Leak measurement, can not be used in flue gas environment, using catalytic combustion principle, low power MCU chip and intelligent Sensors technology, with aluminum alloy explosion-proof housing and sound and light alarm function.
      Compare
      Empaer AATL-O2 (sound and light alarm) Pathfinder series fixed oxygen Detector
      $338.00 SE
      Empaer AATL-O2 (sound and light alarm) Pathfinder series fixed oxygen Detector
      O20~30%VOLDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias O2, detection range 0-30% VOL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃, Operating humidity: 10% -95% RH (no condensation)
      Compare
      Empaer SPES-O2 series handheld oxygen concentration Detector
      $271.00 SE
      Empaer SPES-O2 series handheld oxygen concentration Detector
      O20~30%VOL
      Detection gas type O2, detection range 0-30% VOL, Response time T90 ≤ national standard, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-H2S Pathfinder series stationary hydrogen sulfide Detector
      $290.00 SE
      Empaer AATL-H2S Pathfinder series stationary hydrogen sulfide Detector
      H2S0~500ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias H2S, detection range 0-500ppm, power supply mode 12~ 36VDC (typical power supply 24VDC), storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃, support zero automatic correction
      Compare
      Empaer APEG-D-CO (4G) Volkswagen Series Stationary Carbon Monoxide Detector
      $368.00 SE
      Empaer APEG-D-CO (4G) Volkswagen Series Stationary Carbon Monoxide Detector
      CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0-1000ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-O2 Pathfinder Series Stationary Oxygen Detector
      $316.00 SE
      Empaer AATL-O2 Pathfinder Series Stationary Oxygen Detector
      O20~30%VOLDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias O2, detection range 0-30% VOL, storage temperature -10 ° C~ 30 ° C, Working pressure 86-106KPA, Working Temperature & Moisture Operating temperature: -40 ° C~ 55 ° C; Operating humidity: 10% -95% RH (no condensation), support zero automatic correction, suitable for multiple industries.
      Compare
      Empaer AATL-EX Pathfinder Series Fixed Gas Detector
      $267.00 SE
      Empaer AATL-EX Pathfinder Series Fixed Gas Detector
      EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias EX, detection range 0-100% LEL, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA.
      Compare
      Empaer AASD-H2 Lightning Series Handheld Hydrogen Detector
      $282.00 SE
      Empaer AASD-H2 Lightning Series Handheld Hydrogen Detector
      H20~100%LEL
      Gas name and alias H2, detection range 0~100% LEL, Response time T90 ≤ national standard, error of indication ≤ national standard, using mode diffusion type, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-CO (sound and light alarm) Pathfinder series stationary carbon monoxide Detector
      $312.00 SE
      Empaer AATL-CO (sound and light alarm) Pathfinder series stationary carbon monoxide Detector
      CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias CO, detection range 0-1000ppm, detection accuracy is better than the national standard accuracy, generally ≤ +/- 3% FS, error of indication 3% FS, Repeatability 1%, storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-EX (4G) Volkswagen Series Fixed Gas Detector
      $344.00 SE
      Empaer APEG-D-EX (4G) Volkswagen Series Fixed Gas Detector
      EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0-100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AATL-CH4 (4G) Pathfinder Series Fixed Methane Detector
      $378.00 SE
      Empaer AATL-CH4 (4G) Pathfinder Series Fixed Methane Detector
      CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer SPES-H2 series handheld hydrogen concentration Detector
      $260.00 SE
      Empaer SPES-H2 series handheld hydrogen concentration Detector
      H20~100%LEL
      Detection gas type H2, detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AASD-CO Lightning Series Handheld Carbon Monoxide Detector
      $267.00 SE
      Empaer AASD-CO Lightning Series Handheld Carbon Monoxide Detector
      CO0~1000ppm
      Gas name and alias CO, detection range 0-1000ppm, using diffusion type, working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), shell material, shell material: PC + soft rubber; non-slip
      Compare
      Empaer AASD-CL2 Lightning Series Handheld Chlorine Detector
      $368.00 SE
      Empaer AASD-CL2 Lightning Series Handheld Chlorine Detector
      CL20~50ppm
      Gas name and alias CL2, detection range 0~50ppm, using mode diffusion type, Response time T90 ≤ national standard, Storage temperature -10 ℃~ 30 ℃, Working pressure 80-120KPA, Shell material Shell material: PC + soft rubber
      Compare
      Empaer AATL-CO Pathfinder Series Stationary Carbon Monoxide Detectors
      $290.00 SE
      Empaer AATL-CO Pathfinder Series Stationary Carbon Monoxide Detectors
      CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Gas name and alias CO, detection range 0-1000ppm, working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA, support zero automatic correction, IP66 protection
      Compare
      Empaer APEG-D-H2 Volkswagen Series Stationary Hydrogen Detector
      $271.00 SE
      Empaer APEG-D-H2 Volkswagen Series Stationary Hydrogen Detector
      H20~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
      Gas name and alias H2, detection range 0~100% LEL, detection accuracy is better than the national standard accuracy, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer APEG-D-H2S (4G) Volkswagen series stationary hydrogen sulfide Detector
      $368.00 SE
      Empaer APEG-D-H2S (4G) Volkswagen series stationary hydrogen sulfide Detector
      H2S0~500ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
      Detection range 0-500ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer SPES-CL2 series handheld chlorine concentration Detector
      $344.00 SE
      Empaer SPES-CL2 series handheld chlorine concentration Detector
      CL20~50ppm
      Detection gas type CL2, detection range 0~50ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      Empaer AASD-H2S Lightning series handheld hydrogen sulfide Detector
      $267.00 SE
      Empaer AASD-H2S Lightning series handheld hydrogen sulfide Detector
      H2S0~500ppm
      Gas name and alias H2S, detection range 0-500ppm, using diffusion type, working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), shell material, shell material: PC + soft rubber
      Compare
      Empaer SPES-CO series handheld carbon monoxide concentration Detector
      $245.00 SE
      Empaer SPES-CO series handheld carbon monoxide concentration Detector
      CO0~1000ppm
      Detect gas type CO, detection range 0-1000ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃
      Compare
      If you don't know how to choose "Gas detector", please consult customer service.
      Focus on online sales of Lab Testing Instruments