$267.00
SE
Empaer AATL-EX Pathfinder Series Fixed Gas Detector
EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias EX, detection range 0-100% LEL, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA.

$223.00
SE
Empaer SPES-CH4 Lone Walker Series Handheld Methane concentration Detector
CH40~100%LEL
Detection gas type CH4, detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$282.00
SE
Empaer AASD-H2 Lightning Series Handheld Hydrogen Detector
H20~100%LEL
Gas name and alias H2, detection range 0~100% LEL, Response time T90 ≤ national standard, error of indication ≤ national standard, using mode diffusion type, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃

$722.00
SE
Empaer AATL-O3 (4G) Pathfinder Series Fixed Ozone Detector
O30~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Detection range 0~100ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃

$668.00
SE
Empaer APEG-D-CH2O (4G) Volkswagen Series Fixed formaldehyde Detector
CH2O0~10ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Detection range 0~10ppm, error of indication 3% FS, Repeatability 1%, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$312.00
SE
Empaer AATL-CO (sound and light alarm) Pathfinder series stationary carbon monoxide Detector
CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CO, detection range 0-1000ppm, detection accuracy is better than the national standard accuracy, generally ≤ +/- 3% FS, error of indication 3% FS, Repeatability 1%, storage temperature -10 ℃~ 30 ℃

$545.00
SE
Empaer SPES-CH2O solitary series handheld formaldehyde concentration Detector
CH2O0~10ppm
Detection gas type CH2O, detection range 0~10ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$344.00
SE
Empaer APEG-D-EX (4G) Volkswagen Series Fixed Gas Detector
EX0~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Detection range 0-100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃

$467.00
SE
Empaer APEG-D-CL2 (4G) Volkswagen Series Stationary Chlorine Detector
CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Detection range 0~50ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃

$411.00
SE
Empaer AATL-CL2 (Sound and Light Alarm) Pathfinder Series Fixed Chlorine Detector
CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CL2, detection range 0~50ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), sound and light alarm storage temperature -10 ℃~ 30 ℃,

$378.00
SE
Empaer AATL-CH4 (4G) Pathfinder Series Fixed Methane Detector
CH40~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃

$260.00
SE
Empaer SPES-H2 series handheld hydrogen concentration Detector
H20~100%LEL
Detection gas type H2, detection range 0~100% LEL, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$267.00
SE
Empaer AASD-CO Lightning Series Handheld Carbon Monoxide Detector
CO0~1000ppm
Gas name and alias CO, detection range 0-1000ppm, using diffusion type, working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), shell material, shell material: PC + soft rubber; non-slip

$389.00
SE
Empaer AATL-CL2 Pathfinder Series Stationary Chlorine Detector
CL20~50ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CL2, detection range 0~50ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA, can control peripherals, full alarm reminder function

$590.00
SE
Empaer AATL-CH2O Pathfinder Series Fixed Formaldehyde Detector
CH2O0~10ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CH2O, detection range 0~10ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA

$955.00
SE
Empaer APEG-D-CO2 (4G) Volkswagen Series Stationary Carbon Dioxide Detector
CO20~5000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Detection range 0~5000ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$901.00
SE
Empaer AATL-CO2 (sound and light alarm) Pathfinder series stationary carbon dioxide Detector
CO20~5000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CO2, detection range 0~5000ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$567.00
SE
Empaer SPES-SO2 series handheld sulfur dioxide concentration Detector
SO20~100ppm
Detection of gas type SO2, detection range 0~100ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$368.00
SE
Empaer AASD-CL2 Lightning Series Handheld Chlorine Detector
CL20~50ppm
Gas name and alias CL2, detection range 0~50ppm, using mode diffusion type, Response time T90 ≤ national standard, Storage temperature -10 ℃~ 30 ℃, Working pressure 80-120KPA, Shell material Shell material: PC + soft rubber

$290.00
SE
Empaer AATL-CO Pathfinder Series Stationary Carbon Monoxide Detectors
CO0~1000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CO, detection range 0-1000ppm, working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA, support zero automatic correction, IP66 protection

$633.00
SE
Empaer AATL-O3 (sound and light alarm) Pathfinder series fixed ozone Detector
O30~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias O3, detection range 0~100ppm, sound and light alarm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃, error of indication 3% FS

$394.00
SE
Empaer APEG-D-O2 (4G) Volkswagen Series Stationary Oxygen Detector
O20~30%VOLDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Detection range 0-30% VOL, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃

$271.00
SE
Empaer APEG-D-H2 Volkswagen Series Stationary Hydrogen Detector
H20~100%LELDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
Gas name and alias H2, detection range 0~100% LEL, detection accuracy is better than the national standard accuracy, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃

$612.00
SE
Empaer AATL-O3 Pathfinder Series Stationary Ozone Detectors
O30~100ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, contact the customer service of the mall.
Gas name and alias O3, detection range 0~100ppm, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation); Storage temperature -10 ℃~ 30 ℃, Working pressure 86-106KPA

$989.00
SE
Empaer AATL-CO2 (4G) Pathfinder Series Stationary CO2 Detector
CO20~5000ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Gas name and alias CO2, detection range 0~5000ppm, error of indication 3% FS, Repeatability 1%, Operating Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation)

$368.00
SE
Empaer APEG-D-H2S (4G) Volkswagen series stationary hydrogen sulfide Detector
H2S0~500ppmDiffusion type (default), circulation type, pipeline type, pump suction type (external). For details, consult the customer service of the mall.
Detection range 0-500ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture Operating temperature: -40 ℃~ 55 ℃; Operating humidity: 10% -95% RH (no condensation), Storage temperature -10 ℃~ 30 ℃

$267.00
SE
Empaer AASD-H2S Lightning series handheld hydrogen sulfide Detector
H2S0~500ppm
Gas name and alias H2S, detection range 0-500ppm, using diffusion type, working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), shell material, shell material: PC + soft rubber

$590.00
SE
Empaer AASD-SO2 Lightning Series Handheld Sulfur Dioxide Detector
SO20~100ppm
Gas name and alias SO2, detection range 0~100ppm, using mode diffusion type, use mode handheld, neck hanging type, automatic zero calibration automatic correction function, working Temperature & Moisture -40 ℃~ 55 ℃, storage temperature -10 ℃~ 30 ℃.

$344.00
SE
Empaer SPES-CL2 series handheld chlorine concentration Detector
CL20~50ppm
Detection gas type CL2, detection range 0~50ppm, error of indication 3% FS, Repeatability 1%, Working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation), storage temperature -10 ℃~ 30 ℃

$856.00
SE
Empaer AASD-CO2 Lightning Series Handheld Carbon Dioxide Detector
CO20~5000ppm
Gas name and alias CO2, detection range 0~5000ppm, Response time T90 ≤ national standard, diffusion type, working Temperature & Moisture -40 ℃~ 55 ℃, 10% -95% RH (no condensation)

If you don't know how to choose "Gas detector", please consult customer service.