Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Result >

      High-Low Temperature Chamber

      237 results
      Featured Hot Price Time
      BENTING CBGDW-80L low/high Temperature Test Chamber -70 ℃/80L
      BENTING CBGDW-80L low/high Temperature Test Chamber -70 ℃/80L
      -70~150℃80L400*500*400mm3℃/min
      Compare
      ZKHS GDW-225D Temperature Cycling Test Chamber -60 ℃~ 150 ℃
      $6418.00 SE
      ZKHS GDW-225D Temperature Cycling Test Chamber -60 ℃~ 150 ℃
      -60~150℃500*600*750mm-20→100℃≈35min
      Interior size 500 * 600 * 750mm, Temperature range -60~150 ℃, Temperature fluctuation ≤ ± 0.5 ℃, Heating rate -20 → 100 ℃ Technologies 35min, Cooling rate 25~ -40 ℃ Technologies 50min
      Compare
      HUDA high-low temperature rapid temperature change Test Chamber QD-E708-1000K40-X15
      $30462.00 SE
      HUDA high-low temperature rapid temperature change Test Chamber QD-E708-1000K40-X15
      -40~150℃1000L1000*1000*1000mm20~98%R.H
      Volume 1000L, Temperature range -40 ℃~ 150 ℃, linear temperature rise and drop 15 ℃/min, in line with GB standards, self-developed multi-channel, multi-stage throttling refrigeration system, remote visual control, application of broadband compression equilibrating temperature control system.
      Compare
      BENTING CBGDW-225L low/high Temperature Test Chamber -70 ℃/225L
      BENTING CBGDW-225L low/high Temperature Test Chamber -70 ℃/225L
      -70~150℃225L600*750*500mm3℃/min
      Compare
      KESIONOTS low/high temperature test chamber KS-OTS-HD80LA temperature control -70 ℃~ 150 ℃
      $5439.00 SE
      KESIONOTS low/high temperature test chamber KS-OTS-HD80LA temperature control -70 ℃~ 150 ℃
      -70℃~150℃80L≈4.0℃/min400*500*400mm
      Temperature control -70 ℃~ 150 ℃, volume 80L, used for high temperature and low temperature reliability test of industrial products, in line with GB standards, nano paint outer box, stainless steel inner box, air-water cooled double-stage compressor.
      Compare
      ZKHS GDJW-800C High and Low Temperature Cyclic Test Chamber -40 ℃~ 150 ℃
      $10049.00 SE
      ZKHS GDJW-800C High and Low Temperature Cyclic Test Chamber -40 ℃~ 150 ℃
      -40~150℃-20→100℃≈35min;-40→100℃≈45min800*1000*1000mm
      Interior size 800 * 1000 * 1000mm, Temperature range -40~150 ℃, Alternating range -40 ℃~ 85 ℃, Temperature fluctuation ≤ ± 0.5 ℃, Heating rate -20 → 100 ℃ Technologies 35min; -40 → 100 ℃ Technologies 45min, Cooling rate 25~ -40 ℃ Technologies 50min; 25~ -60 ℃ Technologies 65min
      Compare
      BENTING CBGDW-225L low/high Temperature Test Chamber -20 ℃/225L
      BENTING CBGDW-225L low/high Temperature Test Chamber -20 ℃/225L
      -20~150℃225L600*750*500mm3℃/min
      Compare
      YIHENG BPH-120C vertical low/high Temperature Test Chamber -60 ℃~ 130 ℃/120L
      $6349.00 SE
      YIHENG BPH-120C vertical low/high Temperature Test Chamber -60 ℃~ 130 ℃/120L
      -60~130℃120L500*400*600mm
      Vertical low/high Temperature Test Chamber, temperature control -60 ℃~ 130 ℃, liner volume 120L, all fluorine-free design, imported compressor, 304 mirror stainless steel liner, independent temperature limit alarm system.
      Compare
      HUDA high-low temperature cycle testing machine QD-E708-1000K60-X5
      $17306.00 SE
      HUDA high-low temperature cycle testing machine QD-E708-1000K60-X5
      -60~150℃1000L1000*1000*1000mm20~98%R.H
      Volume 1000L, Temperature range -60 ℃~ 150 ℃, linear temperature rise and fall 5 ℃/min, in line with GB standards, self-developed multi-channel, multi-stage throttling refrigeration system, remote visual control, application of broadband compression equilibrating temperature control system.
      Compare
      ZKHS GDJW-225D High and Low Temperature Cyclic Test Chamber -60 ℃~ 150 ℃
      $7065.00 SE
      ZKHS GDJW-225D High and Low Temperature Cyclic Test Chamber -60 ℃~ 150 ℃
      -60~150℃-20→100℃≈35min;-40→100℃≈45min500*600*750mm
      Interior size 500 * 600 * 750mm, Temperature range -60~150 ℃, Alternating range -60 ℃~ 85 ℃, Temperature fluctuation ≤ ± 0.5 ℃, Heating rate -20 → 100 ℃ Technologies 35min; -40 → 100 ℃ Technologies 45min, Cooling rate 25~ -40 ℃ Technologies 50min; 25~ -60 ℃ Technologies 65min
      Compare
      HZAOC GDJW-010B high-low temperature cyclic Test Chamber -30-150 ℃/1000L
      $11044.00 SE
      HZAOC GDJW-010B high-low temperature cyclic Test Chamber -30-150 ℃/1000L
      -30~150℃1000L1.0~3.0℃/min1000*1000*1000mm
      Compare
      HZAOC GDJW-800B Parts Temperature Cycling Test Chamber -30 ℃~ 150 ℃/800L
      $10112.00 SE
      HZAOC GDJW-800B Parts Temperature Cycling Test Chamber -30 ℃~ 150 ℃/800L
      -30~150℃800L1000*800*1000mm1.0~3.0℃/min
      -30 ℃~ 150 ℃; volume 800L; French "Taikang" fully enclosed compressor refrigeration, porcelain frame nickel-chromium wire electric heater; upper air supply and lower air return method; PT100 temperature measurement Sensors.
      Compare
      HZAOC GDJW-250C Experimental Temperature Cycling Test Chamber -40 ℃~ 150 ℃/250L
      $7776.00 SE
      HZAOC GDJW-250C Experimental Temperature Cycling Test Chamber -40 ℃~ 150 ℃/250L
      -40~150℃250L500*600*810mm1.0~3.0℃/min
      -40 ℃~ 150 ℃; 250L volume; French closed low temperature refrigeration compressor, ultra-fine Glass thermal insulation cotton thermal insulation; upper air supply and lower air return mode; PT100 temperature measurement Sensors; long life heater.
      Compare
      ZKHS GDJW-010B High and Low Temperature Cyclic Test Chamber -20 ℃~ 150 ℃
      $10317.00 SE
      ZKHS GDJW-010B High and Low Temperature Cyclic Test Chamber -20 ℃~ 150 ℃
      -20~150℃1000*1000*1000mm-20→100℃≈35min;-40→100℃≈45min
      Interior size 1000 * 1000 * 1000mm, Temperature range -20~150 ℃, Alternating range -20 ℃~ 85 ℃, Temperature fluctuation ≤ ± 0.5 ℃, Heating rate -20 → 100 ℃ Technologies 35min; -40 → 100 ℃ Technologies 45min, cooling rate 25~ -40 ℃ Technologies 50min; 25~ -60 ℃ Technologies 65min
      Compare
      HZAOC GDJW-010B Experimental Temperature Cycling Test Chamber -30 ℃~ 150 ℃/1000L
      $11044.00 SE
      HZAOC GDJW-010B Experimental Temperature Cycling Test Chamber -30 ℃~ 150 ℃/1000L
      -30~150℃1000L1000*1000*1000mm1.0~3.0℃/min
      -30 ℃~ 150 ℃; volume 1000L; French "Taikang" fully enclosed compressor refrigeration, porcelain frame nickel-chromium wire electric heater; upper air supply and lower air return method; PT100 temperature measurement Sensors.
      Compare
      HZAOC GDJW-500C Material Temperature Cycling Test Chamber -40 ℃~ 150 ℃/500L
      $8865.00 SE
      HZAOC GDJW-500C Material Temperature Cycling Test Chamber -40 ℃~ 150 ℃/500L
      -40~150℃500L1.0~3.0℃/min700*800*900mm
      -40 ℃~ 150 ℃; 500L volume; French closed low temperature refrigeration compressor, ultra-fine Glass thermal insulation cotton thermal insulation; upper air supply and lower air return mode; PT100 temperature measurement Sensors; long life heater.
      Compare
      KESIONOTS High and Low Temperature Environmental Test Chamber KS-OTS-HD408LB Temperature Control -60 ℃~ 150 ℃
      $6623.00 SE
      KESIONOTS High and Low Temperature Environmental Test Chamber KS-OTS-HD408LB Temperature Control -60 ℃~ 150 ℃
      -60~150℃408L600*850*800mm≈4.0℃/min
      Temperature control -60 ℃~ 150 ℃, volume 408L, for high temperature and low temperature reliability test, the outer box is high-grade cold plate nano paint, the inner box is stainless steel, air-water cooled double-stage compressor refrigeration.
      Compare
      ZKHS GDJW-010C High and Low Temperature Cyclic Test Chamber -40 ℃~ 150 ℃
      $11359.00 SE
      ZKHS GDJW-010C High and Low Temperature Cyclic Test Chamber -40 ℃~ 150 ℃
      -40~150℃-20→100℃≈35min;-40→100℃≈45min1000*1000*1000mm
      Interior size 1000 * 1000 * 1000mm, Temperature range -40~150 ℃, Alternating range -40 ℃~ 85 ℃, Temperature fluctuation ≤ ± 0.5 ℃, Heating rate -20 → 100 ℃ Technologies 35min; -40 → 100 ℃ Technologies 45min, Cooling rate 25~ -40 ℃ Technologies 50min; 25~ -60 ℃ Technologies 65min
      Compare
      HUDA experiment rapid temperature change Test Chamber QD-E708-150K40-X15
      $20344.00 SE
      HUDA experiment rapid temperature change Test Chamber QD-E708-150K40-X15
      -40~150℃150L20~98%R.H500*500*600mm
      Volume 150L, temperature control -40 ℃~ 150 ℃, linear temperature rise and drop 15 ℃/min, self-developed multi-channel, multi-stage throttling refrigeration system, in line with GB standards, remote visual control, application of broadband compression equilibrate temperature control system.
      Compare
      ZKHS GDW-010C Temperature Cycling Test Chamber -40 ℃~ 150 ℃
      $10175.00 SE
      ZKHS GDW-010C Temperature Cycling Test Chamber -40 ℃~ 150 ℃
      -40~150℃-20→100℃≈35min;-40→100℃≈45min1000*1000*1000mm
      Interior size 1000 * 1000 * 1000mm, Temperature range -40~150 ℃, Temperature fluctuation ≤ ± 0.5 ℃, Heating rate -20 → 100 ℃ Technologies 35min; -40 → 100 ℃ Technologies 45min
      Compare
      HZAOC GDJW-250B Material Temperature Cycling Test Chamber -30 ℃~ 150 ℃/250L
      $7413.00 SE
      HZAOC GDJW-250B Material Temperature Cycling Test Chamber -30 ℃~ 150 ℃/250L
      -30~150℃250L1.0~3.0℃/min500*600*810mm
      -30 ℃~ 150 ℃; volume 250L; French "Taikang" fully enclosed compressor refrigeration, porcelain frame nickel-chromium wire electric heater; upper air supply and lower air return method; PT100 temperature measurement Sensors.
      Compare
      HZAOC GDJW-150B Temperature Cycling Test Chamber -30 ℃~ 150 ℃/150L
      $6829.00 SE
      HZAOC GDJW-150B Temperature Cycling Test Chamber -30 ℃~ 150 ℃/150L
      -30~150℃150L1.0~3.0℃/min500*500*600mm
      -30 ℃~ 150 ℃; volume 150L; French "Taikang" fully enclosed compressor refrigeration, porcelain frame nickel-chromium wire electric heater; upper air supply and lower air return method; PT100 temperature measurement Sensors.
      Compare
      HUDA material rapid temperature change Test Chamber QD-E708-512K40-X15
      $24391.00 SE
      HUDA material rapid temperature change Test Chamber QD-E708-512K40-X15
      -40~150℃512L20~98%R.H800*800*800mm
      Volume 512L, Temperature range -40 ℃~ 150 ℃, linear temperature rise and fall 15 ℃/min, in line with GB standards, self-developed multi-channel, multi-stage throttling refrigeration system, remote visual control, application of broadband compression equilibrating temperature control system.
      Compare
      HUDA high-low temperature rapid change testing machine QD-E708-1000K60-X10
      $26415.00 SE
      HUDA high-low temperature rapid change testing machine QD-E708-1000K60-X10
      -60~150℃1000L1000*1000*1000mm20~98%R.H
      Volume 1000L, Temperature range -60 ℃~ 150 ℃, linear temperature rise and drop 10 ℃/min, in line with GB standards, self-developed multi-channel, multi-stage throttling refrigeration system, remote visual control, application of broadband compression equilibrating temperature control system.
      Compare
      BENTING CBGDW-800L low/high Temperature Test Chamber -40 ℃/800L
      BENTING CBGDW-800L low/high Temperature Test Chamber -40 ℃/800L
      -40~150℃800L3℃/min1000*1000*800mm
      Compare
      KESIONOTS low/high temperature test chamber KS-OTS-HD150LB temperature control -60 ℃~ 150 ℃
      $5818.00 SE
      KESIONOTS low/high temperature test chamber KS-OTS-HD150LB temperature control -60 ℃~ 150 ℃
      -60~150℃150L500*600*500mm≈4.0℃/min
      Temperature control -60 ℃~ 150 ℃, volume 150L, for high temperature, low temperature reliability test, the outer box is high-grade cold plate nano paint, the inner box is stainless steel, air-water cooled double-stage compressor refrigeration.
      Compare
      HZAOC GDJW-500A Experimental Temperature Cycling Test Chamber -20 ℃~ 150 ℃/500L
      $7918.00 SE
      HZAOC GDJW-500A Experimental Temperature Cycling Test Chamber -20 ℃~ 150 ℃/500L
      -20~150℃500L1.0~3.0℃/min700*800*900mm
      -20 ℃~ 150 ℃; 500L volume; French closed low temperature refrigeration compressor, ultra-fine Glass thermal insulation cotton thermal insulation; upper air supply and lower air return method; PT100 temperature measurement Sensors; long life heater.
      Compare
      HUDA electronic rapid temperature change Test Chamber QD-E708-512K60-X15
      $28439.00 SE
      HUDA electronic rapid temperature change Test Chamber QD-E708-512K60-X15
      -60~150℃512L800*800*800mm20~98%R.H
      Volume 512L, Temperature range -60 ℃~ 150 ℃, linear temperature rise and fall 15 ℃/min, in line with GB standards, self-developed multi-channel, multi-stage throttling refrigeration system, remote visual control, application of broadband compression equilibrating temperature control system.
      Compare
      HUDA electronic rapid temperature change Test Chamber QD-E708-1000K40-X5
      $13259.00 SE
      HUDA electronic rapid temperature change Test Chamber QD-E708-1000K40-X5
      -40~150℃1000L20~98%R.H1000*1000*1000mm
      Volume 1000L, Temperature range -40 ℃~ 150 ℃, linear temperature rise and fall 5 ℃/min, in line with GB standards, self-developed multi-channel, multi-stage throttling refrigeration system, remote visual control, application of broadband compression equilibrating temperature control system.
      Compare
      HZAOC GDJW-010D high-low temperature cyclic Test Chamber -60-150 ℃/1000L
      $11849.00 SE
      HZAOC GDJW-010D high-low temperature cyclic Test Chamber -60-150 ℃/1000L
      -60~150℃1000L1.0~3.0℃/min1000*1000*1000mm
      Compare
      If you don't know how to choose "High-Low Temperature Chamber", please consult customer service.
      Focus on online sales of Lab Testing Instruments