Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Result > Certificate:Without >

      Coating Thickness Gauge

      129 results
      Featured Hot Price Time
      LEEB242 (F1) paints Thickness Gauge with external magnetic probe
      LEEB242 (F1) paints Thickness Gauge with external magnetic probe
      magnetic induction0 ~ 1250µm±3%
      Compare
      German EPK MiniTest 600 B-FN coated platings Thickness Gauge, iron-based/non-iron-based
      German EPK MiniTest 600 B-FN coated platings Thickness Gauge, iron-based/non-iron-based
      Magnetic Induction + eddy Current0~2000μm±2%
      For iron-based and non-iron-based coatings thickness measurement, with wire probe, to meet the different metal substrate measurement, thickness measurement range of 0~2000μm, error +/- 2%, in line with ISO, DIN, BS, ASTM standards.
      Compare
      LEEB211 coating Film Thickness Gauge Eletroplating, chemical industry, shipbuilding, light industry, automobile and other fields
      LEEB211 coating Film Thickness Gauge Eletroplating, chemical industry, shipbuilding, light industry, automobile and other fields
      eddy current0 ~ 1250µm±3%
      Measurement range 0~1250μm, error range +/- 3%, resolution 0.1μm, widely used in chemical industry, light industry, Eletroplating, anti-corrosion, automotive, shipbuilding, aerospace, aviation, commodity inspection and other fields.
      Compare
      IWAVE WH-81 Coating Thickness Gauge magnetic thickness measurement method 0~1250μm
      $164.00 SE
      IWAVE WH-81 Coating Thickness Gauge magnetic thickness measurement method 0~1250μm
      Magnetic Induction0~1250μm±3%
      Measurement range 0~1250μm, error range +/- 3%, can quickly and accurately detect the thickness of coatings.
      Compare
      DONGRU DR380 portable Film Thickness Gauge magnetic and eddy current Thickness Gauge
      $413.00 SE
      DONGRU DR380 portable Film Thickness Gauge magnetic and eddy current Thickness Gauge
      Magnetic Induction + eddy Current0 ~ 1250µm±1~3%
      Magnetic eddy current dual-use Film Thickness Gauge, thickness range 0~1250 microns, error accuracy +/- 1~ 3%, with zero, two, multi-point calibrated, can store 2000 data, using imported high-quality metal probe.
      Compare
      Linshang LS221 Coating Thickness Gauge Fe/NFe 2000μm
      $245.00 SE
      Linshang LS221 Coating Thickness Gauge Fe/NFe 2000μm
      Magnetic induction + eddy current0 ~ 2000m±3%
      Reaction time 0.5s; Aluminum dual function; Measurement; Split probe; Range 0-2000um; Error range ± (3% + 2um of reading); Minimum matrix Film thickness Fe0.2mm/NFe0.05mm.
      Compare
      DONGRU DR320 Coating Thickness Gauge electromagnetic induction principle for magnetic metal substrate surface platings measurement
      $304.00 SE
      DONGRU DR320 Coating Thickness Gauge electromagnetic induction principle for magnetic metal substrate surface platings measurement
      Magnetic Induction0 ~ 1250µm±3%
      Magnetic Induction measurement, built-in probe, thickness measurement range 0~1250μm, error accuracy +/- 3%, with statistical function, single and continuous measurement, can store 116 data, can be connected to computer printing data.
      Compare
      Coating Thickness Gauge AMITTARI AC-112H Special magnetic Induction Coating Thickness Gauge
      $599.00 SE
      Coating Thickness Gauge AMITTARI AC-112H Special magnetic Induction Coating Thickness Gauge
      magnetic induction0 ~ 12000μ m±3%
      Magnetic Induction coating thickness measurement, thickness measurement range 0~12000μm, error +/- 3%, suitable for thick coatings such as anti-corrosion coatings thickness measurement, data can be transmitted through USB connection.
      Compare
      KAIRDA NDT530 (F1) Galvanized Thickness Gauge with magnetic Induction Probe
      $288.00 SE
      KAIRDA NDT530 (F1) Galvanized Thickness Gauge with magnetic Induction Probe
      Magnetic Induction0~1250μm±2%
      Measurement range 0~1250μm, error range +/- 2%, resolution 0.1μm, probe contact parts plated hard chrome or ruby, durable, with automatic identification probe function, for measurement of magnetic metal substrate on the nonmagnetic Coating thickness.
      Compare
      AMITTARI AC-110MC Integrated Coating Thickness Gauge Dual function Film Thickness Gauge 0~500μm
      $265.00 SE
      AMITTARI AC-110MC Integrated Coating Thickness Gauge Dual function Film Thickness Gauge 0~500μm
      ± 1 ~ 5% / ± 3.5µm
      Standard test range 0~500um/0~20mil, resolution 0.1μm | 1μm, error range +/-1~ 5 %/ +/- 3.5μm, thinnest substrate 0.3mm
      Compare
      AMITTARI AC-990 Coating Thickness Gauge dual function, thickness measurement range 0~500um
      $265.00 SE
      AMITTARI AC-990 Coating Thickness Gauge dual function, thickness measurement range 0~500um
      Magnetic induction + eddy current0 ~ 500µm±3%
      Magnetic Induction + eddy Current, Measurement range 0~500μm, error range +/- 3%, resolution 0.1μm | 1μm, minimum measurement surface φ 26mm, meet the standards ISO2178, ISO2360, GB4956, GB4957
      Compare
      Dual-use Coating Thickness Gauge AMITTARI AC-110AS External thickness probe type, thickness range 0~1250um
      $341.00 SE
      Dual-use Coating Thickness Gauge AMITTARI AC-110AS External thickness probe type, thickness range 0~1250um
      Magnetic Induction + eddy Current0~1250μm±3%
      Magnetic eddy current dual function, thickness measurement accuracy +/- 3%; automatic memory calibrated value, optional RS-232C/USB/Bluetooth data processing interface.
      Compare
      AMITTARI AC-110A built-in thickness probe with resolution of 0.1 μm
      $341.00 SE
      AMITTARI AC-110A built-in thickness probe with resolution of 0.1 μm
      Magnetic induction + eddy current0 ~ 1250µm±3%
      Built-in thickness probe, magnetic Induction and eddy Current dual-use thickness measurement, thickness measurement range 0~1250μm, error +/- 3%, support single and continuous measurement, optional Interface transmission data.
      Compare
      Coating Thickness Gauge AMITTARI AC-110BS Coating Thickness Gauge
      $506.00 SE
      Coating Thickness Gauge AMITTARI AC-110BS Coating Thickness Gauge
      Magnetic induction + eddy current0 ~ 1250µm±3%
      Magnetic Induction and eddy Current dual function, can test magnetic and nonmagnetic substrate, thickness range 0~1250μm, error +/- 3%, can store 99 sets of data, in line with ISO2178, ISO2360, GB4956, GB4957 standards.
      Compare
      DONGRU DR230 Coating Thickness Gauge can automatically identify ferrous or non-ferrous substrate Film Thickness Gauge
      $285.00 SE
      DONGRU DR230 Coating Thickness Gauge can automatically identify ferrous or non-ferrous substrate Film Thickness Gauge
      Magnetic Induction + eddy Current0 ~ 1000µm±3%
      Magnetic Induction and eddy Current thickness measurement, automatic substrate identification, thickness range 0~1000μm, error accuracy +/- 3%, built-in F and NF probes, thinnest substrate 0.4mm, support zero and two point calibrate.
      Compare
      Leeb221 Coating Thickness Gauge to detect the thickness of non-conductive coated Films on non-metallic substrates
      Leeb221 Coating Thickness Gauge to detect the thickness of non-conductive coated Films on non-metallic substrates
      eddy current0 ~ 1250µm±3%
      Coating Thickness Gauge, measurement of non-conductive coated Film thickness on non-metallic substrates, thickness measurement range 0~1250μm, accuracy ± 3%, one point calibrated mode, can store 500 measurement values.
      Compare
      DONGRU DR5000S Coating Thickness Gauge 0~5000μm
      $257.00 SE
      DONGRU DR5000S Coating Thickness Gauge 0~5000μm
      Magnetic Induction0 ~ 5000μ m±3%
      Compare
      Statistical Coating Thickness Gauge AMITTARI AC-110B Integrated Sensors can store 99 sets of thickness measurement data
      $506.00 SE
      Statistical Coating Thickness Gauge AMITTARI AC-110B Integrated Sensors can store 99 sets of thickness measurement data
      Magnetic Induction + eddy Current0~1250μm±3%
      Built-in probe, magnetic Induction and eddy Current dual thickness measurement principle, thickness measurement range 0~1250μm, error +/- 3%, in line with GB standard, with data statistics function, can store 99 sets of data.
      Compare
      DONGRU DR120 Coating Thickness Gauge
      $167.00 SE
      DONGRU DR120 Coating Thickness Gauge
      Magnetic Induction0 ~ 1500m± (3% + 1.5µm)
      Compare
      Leeb220 Magnetoresistive Thickness Gauge, Non-Magnetic Coating on Magnetic Metal Substrate Film thickness
      Leeb220 Magnetoresistive Thickness Gauge, Non-Magnetic Coating on Magnetic Metal Substrate Film thickness
      magnetic induction0 ~ 1250µm±3%
      Magnetic induction thickness measurement principle, measurement of magnetic metal substrate coated Film thickness, thickness measurement range 0~1250μm, accuracy ± 3%, the thinnest substrate 0.5mm, data storage 500 measurement values.
      Compare
      DONGRU DR3000 dual-use Coating Thickness Gauge 0~3000μm
      $257.00 SE
      DONGRU DR3000 dual-use Coating Thickness Gauge 0~3000μm
      Magnetic Induction + eddy Current0 ~ 3000μ m±3%
      Compare
      DONGRU DR130 Coating Thickness Gauge
      $183.00 SE
      DONGRU DR130 Coating Thickness Gauge
      Magnetic Induction + eddy Current0 ~ 1500m± (3% + 1.5µm)
      Compare
      Germany EPK MikroTest S10 McCourt rubber layer Thickness Gauge, thickness measurement: 2.5~ 10mm
      $975.00 SE
      Germany EPK MikroTest S10 McCourt rubber layer Thickness Gauge, thickness measurement: 2.5~ 10mm
      mechanical2500~10000μm±5%
      10Mm range, no need to use any power supply and battery, magnetic attraction principle, can measure the thickness of enamel, plastic and rubber layer on steel, mechanical Impact resistance, acid resistance and solvent corrosion, no need to calibrate.
      Compare
      CHINA CTG-800-3000F Coating Thickness Gauge, Integrated Iron-based Standard Type
      $206.00 SE
      CHINA CTG-800-3000F Coating Thickness Gauge, Integrated Iron-based Standard Type
      magnetic induction0 ~ 3000μ m±2%
      Magnetic induction principle, super wear-resistant cemented carbide probe, measuring thickness up to 3000μm, measurement accuracy ± 2% + 1μm, reaction speed up to 0.3 seconds/time, with temperature compensation.
      Compare
      Defelsko PosiTest DFT Combo Coating Thickness Gauge for measurement of coarse or cylindrical surface coatings
      $818.00 SE
      Defelsko PosiTest DFT Combo Coating Thickness Gauge for measurement of coarse or cylindrical surface coatings
      Magnetic Induction + eddy Current0~1000µm±3%
      No need to calibrate the automatic identification substrate, with ruby probe, can measure cylindrical pipe and other curved surface coatings, the screen supports multi-angle swirl/spin display.
      Compare
      Defelsko PosiTest DFT Ferrous steel Coating Thickness Gauge nonmagnetic coatings
      $607.00 SE
      Defelsko PosiTest DFT Ferrous steel Coating Thickness Gauge nonmagnetic coatings
      Magnetic Induction0~1000µm±3%
      Range 1000 microns, +/- 3% accuracy, automatic swirl/spin high definition display, built-in wear-resistant ruby probe, V-groove probe is suitable for rough and cylindrical workpieces such as pipes and other curved surfaces Coating thickness measurement.
      Compare
      LANDTEK CM8825Fn platings Thickness Measurement Instrument Dual function coating Thickness Measurement Instrument
      $386.00 SE
      LANDTEK CM8825Fn platings Thickness Measurement Instrument Dual function coating Thickness Measurement Instrument
      Magnetic induction + eddy current0 ~ 1250µm±3%
      Dual function thickness measurement, built-in probe, automatic identification of substrate; RS232 interface; automatic memory calibrating; hand-held part of the groove design; can be purchased separately USB and Bluetooth data output.
      Compare
      Mattel MCT200 coated platings Thickness Gauge, thickness range 0~1250μm with F1 probe
      $487.00
      Mattel MCT200 coated platings Thickness Gauge, thickness range 0~1250μm with F1 probe
      Magnetic Induction + eddy Current0~1250μm±3%
      Compare
      Leeb222 (N1) eddy current Thickness Gauge for non-magnetic metal substrates
      Leeb222 (N1) eddy current Thickness Gauge for non-magnetic metal substrates
      eddy current0 ~ 1250µm±3%
      1250 micron range, ± 3% error, eddy current thickness measurement; storage capacity 500 readings; limits can be set.
      Compare
      DONGRU DR260 platings Thickness testing instrument magnetic coating Thickness testing instrument
      $270.00 SE
      DONGRU DR260 platings Thickness testing instrument magnetic coating Thickness testing instrument
      Magnetic Induction0 ~ 1250µm±1~3%
      Magnetic Induction, Measurement range 0~1250μm, error range +/- (1% -3%) H + 1.5μm, resolution 0.1μm /1 μm, Display screen 2.3 inch large color screen
      Compare
      If you don't know how to choose "Coating Thickness Gauge", please consult customer service.
      Focus on online sales of Lab Testing Instruments