      Featured Hot Price Time
      KAIRDA NDT530 (N1) Zinc Coating Thickness Gauge with eddy Current Probe
      $288.00 SE
      KAIRDA NDT530 (N1) Zinc Coating Thickness Gauge with eddy Current Probe
      Eddy Current0~1250μm±2%
      Measurement range 0~1250μm, error range +/- 2%, resolution 0.1μm, can be used to measure the thickness of nonconductive coatings on non-ferrous metal substrates.
      Compare
      LEEB211 coating Film Thickness Gauge Eletroplating, chemical industry, shipbuilding, light industry, automobile and other fields
      LEEB211 coating Film Thickness Gauge Eletroplating, chemical industry, shipbuilding, light industry, automobile and other fields
      eddy current0 ~ 1250µm±3%
      Measurement range 0~1250μm, error range +/- 3%, resolution 0.1μm, widely used in chemical industry, light industry, Eletroplating, anti-corrosion, automotive, shipbuilding, aerospace, aviation, commodity inspection and other fields.
      Compare
      Leeb221 Coating Thickness Gauge to detect the thickness of non-conductive coated Films on non-metallic substrates
      Leeb221 Coating Thickness Gauge to detect the thickness of non-conductive coated Films on non-metallic substrates
      eddy current0 ~ 1250µm±3%
      Coating Thickness Gauge, measurement of non-conductive coated Film thickness on non-metallic substrates, thickness measurement range 0~1250μm, accuracy ± 3%, one point calibrated mode, can store 500 measurement values.
      Compare
      Leeb222 (N1) eddy current Thickness Gauge for non-magnetic metal substrates
      Leeb222 (N1) eddy current Thickness Gauge for non-magnetic metal substrates
      eddy current0 ~ 1250µm±3%
      1250 micron range, ± 3% error, eddy current thickness measurement; storage capacity 500 readings; limits can be set.
      Compare
      LANDTEK CM8826n dry Film Thickness Gauge measurement of non-metallic coatings on nonmagnetic metallic substrates
      $309.00 SE
      LANDTEK CM8826n dry Film Thickness Gauge measurement of non-metallic coatings on nonmagnetic metallic substrates
      Eddy Current0~1250μm±3%
      LANDTEK Utility; External Probe, 1250μm; Eddy Current Thickness Measurement; RS232 Interface; Single or Continuous Measurement mode; Wear-resistant hard metal spring guide sleeve probe; optional USB and Bluetooth data output.
      Compare
      LANDTEK CM8823 film thickness eddy Current Coating Thickness Gauge
      $257.00 SE
      LANDTEK CM8823 film thickness eddy Current Coating Thickness Gauge
      eddy current0 ~ 1000µm±3%
      Eddy Current thickness measurement principle, split N-type probe, thickness measurement range 0~1000μm, error range +/- 3%, no supporting software, can be used for nonconductive coating testing on aluminum, with automatic shutdown function, can be customized Miscellaneous large range.
      Compare
      LANDTEK CM8825N Handheld Thickness Gauge Integrated Handheld Thickness Gauge
      $309.00 SE
      LANDTEK CM8825N Handheld Thickness Gauge Integrated Handheld Thickness Gauge
      eddy current0 ~ 1250µm±3%
      Built-in probe, eddy Current principle; 1250μm; RS232 interface; automatic memory calibrating and identification substrate; RS232 interface; hand-held part groove design.
      Compare
      LANDTEK CM8829n paint Thickness Gauge, integrated eddy current paint Thickness Gauge
      $309.00 SE
      LANDTEK CM8829n paint Thickness Gauge, integrated eddy current paint Thickness Gauge
      eddy current0 ~ 1250µm±3%
      Built-in probe, can be operated with one hand; Single and continuous two measurement modes; Automatic memory calibrating; eddy Current thickness measurement; USB and Bluetooth data output can be purchased separately.
      Compare
      LEEB leeb252 Coating Thickness Gauge magnetic Induction/eddy Current dual-use automatic identification substrate
      LEEB leeb252 Coating Thickness Gauge magnetic Induction/eddy Current dual-use automatic identification substrate
      Magnetic Induction + eddy Current0~1250μm±3%
      Measurement principle: magnetic Induction + eddy Current, Measurement range 0~1250μm, error range +/- 3%, resolution 1μm, is a built-in probe integrated structure of the dual-use Thickness Gauge, the probe can automatically identify the magnetic metal substrate and nonmagnetic metal substrate, accurate measurement of the thickness of the coating.
      Compare
      LEEB Leeb231 eddy Current Coating Thickness Gauge Measurement range 0~1250μm
      $332.00
      LEEB Leeb231 eddy Current Coating Thickness Gauge Measurement range 0~1250μm
      Eddy Current0~1250μm
      Measurement range 0~1250μm, support continuous measurement and single Measurement mode, with statistical function, Measurement accuracy +/- 3%.
      Compare
      LANDTEK Thickness Gauge Probe 90 ° Right Angle Aluminum Based Probe
      $226.00 SE
      LANDTEK Thickness Gauge Probe 90 ° Right Angle Aluminum Based Probe
      eddy current
      Right angle 90 degree probe, suitable for narrow area thickness measurement; eddy Current principle.
      Compare
      If you don't know how to choose "Coating Thickness Gauge", please consult customer service.