$386.00
SE
LANDTEK CM8829S platings Thickness Gauge F magnetic Induction /NF eddy current Ferromagnetic metal substrates Non-ferrous magnetic coatings, platings
Magnetic induction + eddy current0 ~ 1250µm±3%
Magnetic Induction eddy Current dual function platings thickness measurement, thickness measurement range 0~1250μm, error range +/- 3%, single or continuous measurement, measurement of copper, aluminum, zinc, tin and other substrate enamel, rubber, paints, plastic layer and other film thickness.

$309.00
SE
LANDTEK CM8829F magnetic Thickness Gauge, integrated F magnetic Induction Film Thickness Gauge
magnetic induction0 ~ 1250µm±3%
1250μm thickness measurement; Automatic memory calibrating, magnetic Induction; RS232C interface; optional USB and Bluetooth data output.

$489.00
SE
LANDTEK CM8855 coating Film Thickness Gauge Integrated F magnetic Induction /NF eddy current statistical function
Magnetic induction + eddy current0 ~ 1250µm±3%
1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification substrate; statistical function, single and continuous Measurement mode; optional USB and Bluetooth data output.

$226.00
SE
DONGRU DR220 (upgraded version) Integrated Coating Thickness Gauge 0-2000μm
Magnetic Induction0 ~ 2000m±3%

$386.00
SE
LANDTEK CM8829Fn Coating Thickness Gauge, integrated paints Thickness Gauge Film Thickness Gauge
Magnetic Induction + eddy Current0~1250μm±3%
Built-in probe, dual function thickness measurement; Single and continuous two measurement modes; Automatic memory calibrating and identification substrate; RS232C interface; USB and Bluetooth data output can be purchased separately.

$489.00
SE
LANDTEK CM8856 Surface platings Thickness Gauge F magnetic Induction /NF eddy current split platings Thickness Gauge
Magnetic induction + eddy current0 ~ 1250µm±3%
1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification of substrates; with statistical function, single and continuous Measurement mode; hand-held part groove design; USB and Bluetooth data output can be purchased separately.

$568.00
SE
LANDTEK CM-1210-200F Coating Thickness Gauge
0 ~ 200 μm
Magnetic metal substrate thickness measurement, split structure, thickness measurement range 0~200μm, Precision +/- 1~ 3% n or +/- 2.5μm, with single and continuous thickness measurement mode, dedicated to coating measurement on small workpieces.

$350.00
SE
DONGRU DR330 Coating Thickness Gauge measurement of metal surface platings
Magnetic Induction + eddy Current0 ~ 1250µm±3%
Magnetic Induction and eddy Current dual function, thickness range 0~1250μm, error accuracy +/- 3%, with statistical function, measurement of metal surface coating thickness, can store 116 Measured values.

$234.00
SE
IPRE CT150 Coating Thickness Gauge Measurement range 0~1500μm
Magnetic Induction (F), eddy Current (N)F: 0~1500μm; N: 0~1500μm (of which: chrome plating on copper 0~40μm)±3%
Two thickness measurement methods, magnetic and eddy current, can be used to measure the thickness of the nonmagnetic coating layer on the magnetic metal substrate and the thickness of the nonconductive coating layer on the nonmagnetic metal substrate.

$873.00
SE
Linshang LS225 Coating Thickness Gauge with F500 Magnetic Probe + Test Fixture
magnetic induction0.0 ~ 500µm± (0.3 μm + 2%) five-point calibrated
Magnetic induction, split probe, range 0-500um, error range ± (2% of reading + 0.3um); Minimum matrix Film thickness 0.1mm; Equipped with test fixture, the repeability can reach 0.1um; Small size/special-shaped material can be measured.

$245.00
SE
Linshang LS225 industrial grade Coating Thickness Gauge host, probe needs to be purchased separately
Coating Thickness Gauge host, support zero adjustment and multi-point calibrating, with temperature compensation function, with data statistics function, need to buy another probe, can be matched with rack test.

$371.00
SE
IPRE CT300 paints film thickness Measurement Instrument magnetic Induction/eddy Current dual-use
Magnetic Induction (F), eddy Current (N)F: 0~1500μm; N: 0~1500μm (chrome plating on copper: 0~40μm)±3%
Magnetic Induction and eddy Current Thickness Measurement Principle, Support Thermal Printing, Instant Report Output, Can Store 500 Measured values, With Statistical Function.

$404.00
SE
DUBAN DB20-CM211S Split type coating Thickness Gauge, with wire paint film Thickness Gauge
Magnetic Induction + eddy Current0~1250μm±1~3%n ±2.5μm
Measurement principle magnetic Induction + eddy Current, measurement range 0~1250μm, error range +/- 1~ 3% n or +/- 2.5μm, minimum measurement surface 6mm.

$173.00
SE
LINSHANG LS237 Film Thickness Gauge (for automobile paint thickness detection)
Iron: Hall Effect/Aluminum: eddy Current0.0-3500μm≤ +/- ( 3% H + 2 μm) H is the Standard value
Measurement range 0.0-3500 μm, Measurement accuracy ≤ +/- ( 3% H + 2 μm), the use of hard wear-resistant ruby probe to reduce measurement errors, digital signal processing is completed directly on the probe to ensure data stability throughout the measurement process.

$344.00
SE
LINSHANG LS226 Coating thickness gauge Iron non-iron dual-use probe 0.0-2000 μm Measurement range
Fe: magnetic Induction NFe: eddy Current0.0-2000μm
Measurement accuracy up to 2% H + 1μm, support continuous measurement function, 0.1 second fast data acquisition, built-in memory chip can save 9 sets of data, minimum matrix thickness Fe: 0.2mm/NFe: 0.05mm.

Login
LEEB leeb252 Coating Thickness Gauge magnetic Induction/eddy Current dual-use automatic identification substrate
Magnetic Induction + eddy Current0~1250μm±3%
Measurement principle: magnetic Induction + eddy Current, Measurement range 0~1250μm, error range +/- 3%, resolution 1μm, is a built-in probe integrated structure of the dual-use Thickness Gauge, the probe can automatically identify the magnetic metal substrate and nonmagnetic metal substrate, accurate measurement of the thickness of the coating.

$169.00
SE
LINSHANG LS230 Film Thickness Gauge OLED single screen, low temperature resistance
Magnetic Induction + eddy Current0~2000μm±3%
It can measure the thickness in a low temperature environment at minus 40 ℃, the thickness measurement range is 0.0-2000 μm, the built-in integrated dual-function probe has an error range of +/- 3%, and has the function of temperature compensation and digitalization of analog signal terminals.

$173.00
SE
IWAVE WH-82 Coating Thickness Gauge magnetic and eddy current
Magnetic Induction + eddy Current0~1250μm±3%
Magnetic and eddy Current dual-function Thickness Gauge, thickness range 0~1250μm, error +/- 3%, integrated structure, in line with a variety of GB/T and JB/T standards, Appearance Compact and portable.

$254.00
LEEB Leeb252C Metal Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1500μm
Magnetic Induction/eddy Current0~1500μm
Magnetic Induction/eddy Current working principle, range 0~1500 μm, with three Measurement modes including high-precision measurement, with five statistics, support zero and one point calibrated.

$410.00
LEEB Leeb232 Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1250μm
Magnetic Induction/eddy Current0~1250μm
Magnetic Induction/eddy Current Thickness Measurement range 0~1250μm, thickness measurement accuracy +/- 3%, support single and continuous measurement.

$223.00
SE
YIBAI CTG-800Z dual-use Coating Thickness Gauge
Magnetic Induction + eddy Current0~1500μm±2%
Measurement range 0~1500μm, can switch display galvanized gram weight unit, magnetic Induction + eddy Current, Measurement range 0~1500μm, Measurement accuracy +/- 2% H + 1μm.

$296.00
SE
YIBAI CTG-600Z Coating Thickness Gauge can switch to display galvanized gram weight and thickness
Magnetic Induction + eddy Current0~1500μm±2%
With switching display galvanized gram weight and thickness, magnetic Induction + eddy Current, Measurement range 0~1500μm, Measurement accuracy +/- 2% H + 1μm, can quickly, no damage, precision coating, platings thickness measurement.

$571.00
SE
DUBAN DB20-CM212S Statistical Coating Thickness Gauge split probe 0~1250µm
Display 4-digit digital backlit LCD, standard test range 0~1250µm/0~50mil (Miscellaneous Measurement range can be customized), resolution 0.1 µm (below 100 µm); 1 µm (above 100 µm); 0.1mil, Measurement accuracy +/- 1~ 3% n or +/- 2.5 µm or 0.1mil, thinnest substrate 0.3mm/12mil.

$507.00
SE
AMITTARI AC-112BS split Coating Thickness Gauge with statistical function
Measurement accuracy of +/- 1~ 3% n or +/- 2.5 µm or 0.1 mil, iron-based and non-iron-based dual-use Coating Thickness Gauge, Single and Continuous Measurement modes available.

$282.00
SE
YIBAI CTG-600 Coating Thickness Gauge dual-use Film Thickness Gauge
Magnetic Induction + eddy Current0~1500μm±2%
Magnetic Induction + eddy Current, Measurement range 0~1500μm, Measurement accuracy +/- 2% H + 1μm, spring guide sleeve probe with wear-resistant cemented carbide probe, can measure 1-5μm ultra-thin coatings.

$1090.00
HT2916 Ultrasonic Coating thickness gauge Simultaneous measurement of multi-layer thickness, Non-metallic/metallic coating thickness
ultrasound13~ 1000μm (epoxy resin coating), 300~ 14800μm (45 #steel)≤ +/- ( 3% H + 3 μm) H is the Standard value
Coating thickness on plastics, Glass, ceramics and metals can be measured, and the thickness of multi-layer coatings or coatings + substrates can be measured at the same time. Measurement range is 13~ 14800μm, and three Speed of sound settings.

$343.00
SE
AMITTARI AC-112AS Coating Thickness Gauge 5 buttons
0~1250 µm, Measurement accuracy +/- 1~ 3% n, Suitable for measurement of Coating thickness of ferrous and non-ferrous materials, Single and Continuous Measurement modes, Automatic recollection of calibrated values, metric-to-metric unit conversion, manual and automatic shutdown functions.

$316.00
SE
YIBAI CTG-600F5 Coating Thickness Gauge coating 5mm
magnetic Induction0~5000μm±3%
0~5000μm, Measurement accuracy +/- 3% H + 1.5μm, can detect the nonmagnetic Coating thickness on all magnetic substrates, such as lacquers on steel and iron, fire-proof coatings, anti-corrosion coatings, powder coatings, plastics, porcelain, chromium, copper, zinc, etc.

$245.00
SE
YIBAI CTG-600F split iron Coating Thickness Gauge
magnetic Induction0~1500μm±2%
Magnetic Induction, Measurement range 0~1500μm, Measurement accuracy +/- 2% H + 1μm, wear-resistant cemented carbide probe spring guide sleeve probe, light touch Measurement accuracy is good.

$343.00
SE
AMITTARI AC-112CS Coating Thickness Gauge Iron-based aluminum-based dual-use Film thickness meter Single button
Measurement accuracy of +/- 1~ 3% n or +/- 2.5 µm or 0.1 mil, iron-based and non-iron-based dual-use

If you don't know how to choose "Coating Thickness Gauge", please consult customer service.