$371.00
SE
IPRE CT300 paints film thickness Measurement Instrument magnetic Induction/eddy Current dual-use
Magnetic Induction (F), eddy Current (N)F: 0~1500μm; N: 0~1500μm (chrome plating on copper: 0~40μm)±3%
Magnetic Induction and eddy Current Thickness Measurement Principle, Support Thermal Printing, Instant Report Output, Can Store 500 Measured values, With Statistical Function.

$404.00
SE
DUBAN DB20-CM211S Split type coating Thickness Gauge, with wire paint film Thickness Gauge
Magnetic Induction + eddy Current0~1250μm±1~3%n ±2.5μm
Measurement principle magnetic Induction + eddy Current, measurement range 0~1250μm, error range +/- 1~ 3% n or +/- 2.5μm, minimum measurement surface 6mm.

$173.00
SE
LINSHANG LS237 Film Thickness Gauge (for automobile paint thickness detection)
Iron: Hall Effect/Aluminum: eddy Current0.0-3500μm≤ +/- ( 3% H + 2 μm) H is the Standard value
Measurement range 0.0-3500 μm, Measurement accuracy ≤ +/- ( 3% H + 2 μm), the use of hard wear-resistant ruby probe to reduce measurement errors, digital signal processing is completed directly on the probe to ensure data stability throughout the measurement process.

$344.00
SE
LINSHANG LS226 Coating thickness gauge Iron non-iron dual-use probe 0.0-2000 μm Measurement range
Fe: magnetic Induction NFe: eddy Current0.0-2000μm
Measurement accuracy up to 2% H + 1μm, support continuous measurement function, 0.1 second fast data acquisition, built-in memory chip can save 9 sets of data, minimum matrix thickness Fe: 0.2mm/NFe: 0.05mm.

Login
LEEB leeb252 Coating Thickness Gauge magnetic Induction/eddy Current dual-use automatic identification substrate
Magnetic Induction + eddy Current0~1250μm±3%
Measurement principle: magnetic Induction + eddy Current, Measurement range 0~1250μm, error range +/- 3%, resolution 1μm, is a built-in probe integrated structure of the dual-use Thickness Gauge, the probe can automatically identify the magnetic metal substrate and nonmagnetic metal substrate, accurate measurement of the thickness of the coating.

$169.00
SE
LINSHANG LS230 Film Thickness Gauge OLED single screen, low temperature resistance
Magnetic Induction + eddy Current0~2000μm±3%
It can measure the thickness in a low temperature environment at minus 40 ℃, the thickness measurement range is 0.0-2000 μm, the built-in integrated dual-function probe has an error range of +/- 3%, and has the function of temperature compensation and digitalization of analog signal terminals.

$173.00
SE
IWAVE WH-82 Coating Thickness Gauge magnetic and eddy current
Magnetic Induction + eddy Current0~1250μm±3%
Magnetic and eddy Current dual-function Thickness Gauge, thickness range 0~1250μm, error +/- 3%, integrated structure, in line with a variety of GB/T and JB/T standards, Appearance Compact and portable.

$254.00
LEEB Leeb252C Metal Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1500μm
Magnetic Induction/eddy Current0~1500μm
Magnetic Induction/eddy Current working principle, range 0~1500 μm, with three Measurement modes including high-precision measurement, with five statistics, support zero and one point calibrated.

$410.00
LEEB Leeb232 Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1250μm
Magnetic Induction/eddy Current0~1250μm
Magnetic Induction/eddy Current Thickness Measurement range 0~1250μm, thickness measurement accuracy +/- 3%, support single and continuous measurement.

$332.00
LEEB Leeb231 eddy Current Coating Thickness Gauge Measurement range 0~1250μm
Eddy Current0~1250μm
Measurement range 0~1250μm, support continuous measurement and single Measurement mode, with statistical function, Measurement accuracy +/- 3%.

$571.00
SE
DUBAN DB20-CM212S Statistical Coating Thickness Gauge split probe 0~1250µm
Display 4-digit digital backlit LCD, standard test range 0~1250µm/0~50mil (Miscellaneous Measurement range can be customized), resolution 0.1 µm (below 100 µm); 1 µm (above 100 µm); 0.1mil, Measurement accuracy +/- 1~ 3% n or +/- 2.5 µm or 0.1mil, thinnest substrate 0.3mm/12mil.

$507.00
SE
AMITTARI AC-112BS split Coating Thickness Gauge with statistical function
Measurement accuracy of +/- 1~ 3% n or +/- 2.5 µm or 0.1 mil, iron-based and non-iron-based dual-use Coating Thickness Gauge, Single and Continuous Measurement modes available.

$1081.00
LINSHANG LS216 Multilayer Ultrasonic Thickness Gauge Simultaneous measurement of multilayer thickness, suitable for various substrates
Simultaneous measurement of multi-layer coatings or coatings + substrate thickness, Large Measurement range, measurement waveform display, three Speed of sound settings.

$1090.00
HT2916 Ultrasonic Coating thickness gauge Simultaneous measurement of multi-layer thickness, Non-metallic/metallic coating thickness
ultrasound13~ 1000μm (epoxy resin coating), 300~ 14800μm (45 #steel)≤ +/- ( 3% H + 3 μm) H is the Standard value
Coating thickness on plastics, Glass, ceramics and metals can be measured, and the thickness of multi-layer coatings or coatings + substrates can be measured at the same time. Measurement range is 13~ 14800μm, and three Speed of sound settings.

$343.00
SE
AMITTARI AC-112AS Coating Thickness Gauge 5 buttons
0~1250 µm, Measurement accuracy +/- 1~ 3% n, Suitable for measurement of Coating thickness of ferrous and non-ferrous materials, Single and Continuous Measurement modes, Automatic recollection of calibrated values, metric-to-metric unit conversion, manual and automatic shutdown functions.

$316.00
SE
YIBAI CTG-600F5 Coating Thickness Gauge coating 5mm
magnetic Induction0~5000μm±3%
0~5000μm, Measurement accuracy +/- 3% H + 1.5μm, can detect the nonmagnetic Coating thickness on all magnetic substrates, such as lacquers on steel and iron, fire-proof coatings, anti-corrosion coatings, powder coatings, plastics, porcelain, chromium, copper, zinc, etc.

$343.00
SE
AMITTARI AC-112CS Coating Thickness Gauge Iron-based aluminum-based dual-use Film thickness meter Single button
Measurement accuracy of +/- 1~ 3% n or +/- 2.5 µm or 0.1 mil, iron-based and non-iron-based dual-use

$848.00
SE
LEEB LBTQ20-3 Cladding Thickness Gauge (Multifunctional) + F1/90 ° Probe
0-1500um+/- (3% H + 1) um, H is the actual film thickness of the tested object
With magnetic and eddy current two thickness measurement methods, support a variety of probe compatibility, high accuracy, resolution of 0.1 μm, with statistical analysis function and can store 500 sets of data.

$671.00
SE
DUBAN DB22-CM222H Anti-corrosion layer Thickness Gauge
0~12mm
Measurement range 0~12mm, Accuracy 1~ 3% n or 0.2mm, automatic material recognition, support single and continuous measurement, buzzer prompt in operation, can store data and provide statistical functions, support USB, RS-232 and Bluetooth data output.

$610.00
SE
AMITTARI AC-112-200F Coating Thickness Gauge Iron-based film thickness Measurement Instrument
High resolution and wide Measurement range, Single and Continuous Measurement modes, Male/Imperial unit conversion, USB and Bluetooth data output options.

$344.00
SE
YIBAI CTG-600F10 Single iron Coating Thickness Gauge 10mm
magnetic Induction0~10mm±3%
Measurement range 0~10mm, Measurement accuracy +/- 3% H + 1.5μm, can detect the nonmagnetic Coating thickness on all magnetic substrates, such as paint on steel, iron, powder coatings, plastics, porcelain, fire-proof coatings, anti-corrosion layer, enamel, scales, 3PE, etc.

$231.00
SE
YIBAI CTG-800F5 Single Iron Base Large Range Coating Thickness Gauge
magnetic Induction0~5000μm0-1500μm:±2%H+1μm;1500-5000μm:±3%H+1.5μm
Measurement accuracy +/- 2 %~ +/- 3%, LCD lattice LCD screen, magnetic Induction principle, spring guide sleeve probe with wear-resistant cemented carbide probe.

$571.00
SE
DUBAN DB20-CM212 Statistical Coating Thickness Gauge integrated probe 0~1250µm
Standard test range: 0~1250µm/0~50mil (Miscellaneous Measurement range can be customized), resolution: 0.1 µm (below 100 µm); 1 µm (above 100 µm); 0.1mil, Measurement accuracy : +/- 1~ 3% n or +/- 2.5 µm or 0.1mil, thinnest substrate: 0.3mm/12mil, minimum convex diameter: 26mm/1.02inch, minimum concave radius: 50mm/1.97inch.

$404.00
SE
DUBAN DB22-CM221 Coating Thickness Gauge with F/NF probe Measurement range 0~2000μm
0~2000μm (Miscellaneous Measurement range can be customized)
Measuring method F magnetic Induction & NF eddy current, Measurement range 0~2000μm (Miscellaneous Measurement range can be customized), resolution 0.1μm /1 μm, Precision +/- 1~ 3% n or +/- 2.5μm, minimum surface F: convex 1.5mm/concave 25mm; N: convex 3mm/concave 50mm, minimum measurement area 6mm.

$571.00
SE
DUBAN DB22-CM222 Coating Thickness Gauge with F/NF probe Measurement range 0~2000μm
0~2000μm (Miscellaneous Measurement range can be customized)
Measuring method F magnetic Induction & NF eddy current, Measurement range 0~2000μm (Miscellaneous Measurement range can be customized), resolution 0.1μm /1 μm, Precision +/- 1~ 3% n or +/- 2.5μm, minimum curved surface F: convex 1.5mm/concave 25mm; N: convex 3mm/concave 50mm, minimum measurement area 6mm, thinnest substrate 0.3mm.

$173.00
SE
KAIRDA N1 standard probe eddy Current NDT530 Coating Thickness Gauge optional probe
eddy current0 ~ 1250µm±3%

$173.00
SE
KAIRDA F1 standard probe magnetic Induction NDT530 Coating Thickness Gauge optional probe
magnetic induction0 ~ 1250µm±3%
Measurement range 0~1250μm, error range +/- 3%, resolution 0.1mm, designed for measurement of magnetic nonmagnetic coatings on metal substrates.

$312.00
SE
KAIRDA F10 Large Range Probe NDT530 Coating Thickness Gauge optional probe
magnetic induction0 ~ 10000μm

$467.00
SE
KAIRDA F190 ° 90 ° Right Angle Probe Optional probe for NDT530 Coating Thickness Gauge
magnetic induction0 ~ 1250µm±3%
Measurement range 0~1250μm, error range +/- 3%, resolution 0.1mm, test environment magnetic metal matrix, overlay organic materials and other nonmagnetic overlay (such as: paint, lacquer, enamel, enamel, plastic and anode treatment, etc.).

If you don't know how to choose "Coating Thickness Gauge", please consult customer service.