Login
Leeb242 (N1) Coating Thickness Gauge can print measurement data
eddy current0 ~ 1250µm±3%
Built-in thermal printer, can print measurement data, with N1 eddy current thickness probe, range 0~1250μm, error ± 3%, automatic zero calibration, two-point calibrated, optional Miscellaneous probe.

Login
LEEB242 (F1) paints Thickness Gauge with external magnetic probe
magnetic induction0 ~ 1250µm±3%

$413.00
SE
DONGRU DR380 portable Film Thickness Gauge magnetic and eddy current Thickness Gauge
Magnetic Induction + eddy Current0 ~ 1250µm±1~3%
Magnetic eddy current dual-use Film Thickness Gauge, thickness range 0~1250 microns, error accuracy +/- 1~ 3%, with zero, two, multi-point calibrated, can store 2000 data, using imported high-quality metal probe.

$506.00
SE
Statistical Coating Thickness Gauge AMITTARI AC-110B Integrated Sensors can store 99 sets of thickness measurement data
Magnetic Induction + eddy Current0~1250μm±3%
Built-in probe, magnetic Induction and eddy Current dual thickness measurement principle, thickness measurement range 0~1250μm, error +/- 3%, in line with GB standard, with data statistics function, can store 99 sets of data.

$386.00
SE
LANDTEK CM8825Fn platings Thickness Measurement Instrument Dual function coating Thickness Measurement Instrument
Magnetic induction + eddy current0 ~ 1250µm±3%
Dual function thickness measurement, built-in probe, automatic identification of substrate; RS232 interface; automatic memory calibrating; hand-held part of the groove design; can be purchased separately USB and Bluetooth data output.

$487.00
Mattel MCT200 coated platings Thickness Gauge, thickness range 0~1250μm with F1 probe
Magnetic Induction + eddy Current0~1250μm±3%

$386.00
SE
LANDTEK CM8826Fn paints Thickness Gauge, automatic substrate identification
Magnetic induction + eddy current0 ~ 1250µm±3%
Magnetic Induction and eddy Current paints thickness measurement, with F and N split external probes, thickness measurement range 0~1250μm, error accuracy +/- 3%, LCD screen, with memory calibrated value, automatic identification of different substrates.

$543.00
SE
LANDTEK CM8856 (Bluetooth) platings Thickness Gauge, built-in Bluetooth transmitter function
Magnetic induction + eddy current0 ~ 1250µm±3%

$386.00
SE
LANDTEK CM8829S platings Thickness Gauge F magnetic Induction /NF eddy current Ferromagnetic metal substrates Non-ferrous magnetic coatings, platings
Magnetic induction + eddy current0 ~ 1250µm±3%
Magnetic Induction eddy Current dual function platings thickness measurement, thickness measurement range 0~1250μm, error range +/- 3%, single or continuous measurement, measurement of copper, aluminum, zinc, tin and other substrate enamel, rubber, paints, plastic layer and other film thickness.

$489.00
SE
LANDTEK CM8855 coating Film Thickness Gauge Integrated F magnetic Induction /NF eddy current statistical function
Magnetic induction + eddy current0 ~ 1250µm±3%
1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification substrate; statistical function, single and continuous Measurement mode; optional USB and Bluetooth data output.

$386.00
SE
LANDTEK CM8829Fn Coating Thickness Gauge, integrated paints Thickness Gauge Film Thickness Gauge
Magnetic Induction + eddy Current0~1250μm±3%
Built-in probe, dual function thickness measurement; Single and continuous two measurement modes; Automatic memory calibrating and identification substrate; RS232C interface; USB and Bluetooth data output can be purchased separately.

$489.00
SE
LANDTEK CM8856 Surface platings Thickness Gauge F magnetic Induction /NF eddy current split platings Thickness Gauge
Magnetic induction + eddy current0 ~ 1250µm±3%
1250μm integrated probe, dual thickness measurement principle; RS232 interface; automatic memory calibrating and identification of substrates; with statistical function, single and continuous Measurement mode; hand-held part groove design; USB and Bluetooth data output can be purchased separately.

$568.00
SE
LANDTEK CM-1210-200F Coating Thickness Gauge
0 ~ 200 μm
Magnetic metal substrate thickness measurement, split structure, thickness measurement range 0~200μm, Precision +/- 1~ 3% n or +/- 2.5μm, with single and continuous thickness measurement mode, dedicated to coating measurement on small workpieces.

$590.00
SE
LINSHANG LS225 Coating Thickness Gauge with N1500 probe
Eddy Current0~1500μm±2%
Eddy Current, split probe, range 0-1500um, error range +/- (2% of reading + 0.3um); minimum substrate thickness 0.05mm; data statistics function; zero and multi-point calibrated; measurable small size/profiled material.

$404.00
SE
DUBAN DB20-CM211S Split type coating Thickness Gauge, with wire paint film Thickness Gauge
Magnetic Induction + eddy Current0~1250μm±1~3%n ±2.5μm
Measurement principle magnetic Induction + eddy Current, measurement range 0~1250μm, error range +/- 1~ 3% n or +/- 2.5μm, minimum measurement surface 6mm.

$410.00
LEEB Leeb232 Coating Thickness Gauge magnetic Induction/eddy Current Range 0~1250μm
Magnetic Induction/eddy Current0~1250μm
Magnetic Induction/eddy Current Thickness Measurement range 0~1250μm, thickness measurement accuracy +/- 3%, support single and continuous measurement.

$507.00
SE
AMITTARI AC-112BS split Coating Thickness Gauge with statistical function
Measurement accuracy of +/- 1~ 3% n or +/- 2.5 µm or 0.1 mil, iron-based and non-iron-based dual-use Coating Thickness Gauge, Single and Continuous Measurement modes available.

$610.00
SE
AMITTARI AC-112-200F Coating Thickness Gauge Iron-based film thickness Measurement Instrument
High resolution and wide Measurement range, Single and Continuous Measurement modes, Male/Imperial unit conversion, USB and Bluetooth data output options.

$610.00
SE
AMITTARI AC-112-200NF Coating Thickness Gauge Aluminum-based Film Thickness Gauge
High-precision and a wide range of applications, supports the measurement of a variety of coatings and substrate materials. Its advanced nondestructive detection technology, USB and Bluetooth data transfer capabilities.

$467.00
SE
KAIRDA F190 ° 90 ° Right Angle Probe Optional probe for NDT530 Coating Thickness Gauge
magnetic induction0 ~ 1250µm±3%
Measurement range 0~1250μm, error range +/- 3%, resolution 0.1mm, test environment magnetic metal matrix, overlay organic materials and other nonmagnetic overlay (such as: paint, lacquer, enamel, enamel, plastic and anode treatment, etc.).

If you don't know how to choose "Coating Thickness Gauge", please consult customer service.