$341.00
SE
Dual-use Coating Thickness Gauge AMITTARI AC-110AS External thickness probe type, thickness range 0~1250um
Magnetic Induction + eddy Current0~1250μm±3%
Magnetic eddy current dual function, thickness measurement accuracy +/- 3%; automatic memory calibrated value, optional RS-232C/USB/Bluetooth data processing interface.

$341.00
SE
AMITTARI AC-110A built-in thickness probe with resolution of 0.1 μm
Magnetic induction + eddy current0 ~ 1250µm±3%
Built-in thickness probe, magnetic Induction and eddy Current dual-use thickness measurement, thickness measurement range 0~1250μm, error +/- 3%, support single and continuous measurement, optional Interface transmission data.

Login
Leeb221 Coating Thickness Gauge to detect the thickness of non-conductive coated Films on non-metallic substrates
eddy current0 ~ 1250µm±3%
Coating Thickness Gauge, measurement of non-conductive coated Film thickness on non-metallic substrates, thickness measurement range 0~1250μm, accuracy ± 3%, one point calibrated mode, can store 500 measurement values.

$506.00
SE
Statistical Coating Thickness Gauge AMITTARI AC-110B Integrated Sensors can store 99 sets of thickness measurement data
Magnetic Induction + eddy Current0~1250μm±3%
Built-in probe, magnetic Induction and eddy Current dual thickness measurement principle, thickness measurement range 0~1250μm, error +/- 3%, in line with GB standard, with data statistics function, can store 99 sets of data.

Login
Leeb220 Magnetoresistive Thickness Gauge, Non-Magnetic Coating on Magnetic Metal Substrate Film thickness
magnetic induction0 ~ 1250µm±3%
Magnetic induction thickness measurement principle, measurement of magnetic metal substrate coated Film thickness, thickness measurement range 0~1250μm, accuracy ± 3%, the thinnest substrate 0.5mm, data storage 500 measurement values.

$257.00
SE
DONGRU DR3000 dual-use Coating Thickness Gauge 0~3000μm
Magnetic Induction + eddy Current0 ~ 3000μ m±3%

$183.00
SE
DONGRU DR130 Coating Thickness Gauge
Magnetic Induction + eddy Current0 ~ 1500m± (3% + 1.5µm)

$206.00
SE
CHINA CTG-800-3000F Coating Thickness Gauge, Integrated Iron-based Standard Type
magnetic induction0 ~ 3000μ m±2%
Magnetic induction principle, super wear-resistant cemented carbide probe, measuring thickness up to 3000μm, measurement accuracy ± 2% + 1μm, reaction speed up to 0.3 seconds/time, with temperature compensation.

$386.00
SE
LANDTEK CM8825Fn platings Thickness Measurement Instrument Dual function coating Thickness Measurement Instrument
Magnetic induction + eddy current0 ~ 1250µm±3%
Dual function thickness measurement, built-in probe, automatic identification of substrate; RS232 interface; automatic memory calibrating; hand-held part of the groove design; can be purchased separately USB and Bluetooth data output.

$487.00
Mattel MCT200 coated platings Thickness Gauge, thickness range 0~1250μm with F1 probe
Magnetic Induction + eddy Current0~1250μm±3%

Login
Leeb222 (N1) eddy current Thickness Gauge for non-magnetic metal substrates
eddy current0 ~ 1250µm±3%
1250 micron range, ± 3% error, eddy current thickness measurement; storage capacity 500 readings; limits can be set.

$270.00
SE
DONGRU DR260 platings Thickness testing instrument magnetic coating Thickness testing instrument
Magnetic Induction0 ~ 1250µm±1~3%
Magnetic Induction, Measurement range 0~1250μm, error range +/- (1% -3%) H + 1.5μm, resolution 0.1μm /1 μm, Display screen 2.3 inch large color screen

Login
LEEB222 (F1) magnetic Induction Coating Thickness Gauge magnetic metal substrate
magnetic induction0 ~ 1250µm±3%
1250 micron range, +/- 3% error, magnetic Induction thickness measurement; Storage capacity 500 readings; bounds can be set.

$234.00
SE
CHINA CTG-802-1500FN Split iron-aluminum dual-use Coating Thickness Gauge (standard)
±2%H+1μm
Measurement range 0~1500μm, is the standard split coating platings Thickness Gauge for aluminum and iron dual-use, widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields, is a common instrument for material protection.

$246.00
SE
CHINA CTG-802-1500FNV split iron-aluminum dual-use Coating Thickness Gauge (standard/large V type)
±2%H+1μm
Measurement range 0~1500μm, Measurement accuracy +/- 2% H + 1μm, can quickly, nondestructive, precise coating, platings thickness measurement, widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields, is a common instrument for material protection.

$246.00
SE
CHINA CTG-802-3000FN Split iron-aluminum dual-use Coating Thickness Gauge (large range)
±2%H+1μm
Measurement range 0~1500μm, optional Measurement range 0-2000μm, 0-3000μm, resolution 0.1μm (0-99.9 μm), the thinnest substrate 0.3mm, widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields.

$265.00
SE
YIBAI CTG-802-3000FNV split iron and aluminum dual-use standard large V-shaped Coating Thickness Gauge
±2%
Using magnetic Induction and eddy Current automatic conversion technology, Measurement range 0~3000μm, resolution 0.1μm, with super wear-resistant carbide probe, wear-resistant more than 500,000 times, Measurement speed 0.3 seconds/time.

$332.00
SE
LANDTEK CM8822 platings Thickness Gauge measurement of nonconductive coatings on magnetically permeable objects and nonconductive coatings on nonmagnetic metal substrates
Magnetic induction + eddy current0 ~ 1000µm±3%
LANDTEK hot-selling model, measuring thickness up to 1000 μm, standard dual probe; automatic memory calibrating and substrate identification; Single and continuous Measurement mode; optional USB and Bluetooth data output.

$198.00
SE
CHINA CTG-800-1500F Paint Thickness Gauge, Integrated Iron-based Standard Type
magnetic induction0 ~ 1500m±2%
Magnetic induction thickness measurement principle, super wear-resistant cemented carbide probe, thickness measurement up to 1500μm, measurement accuracy ± 2% + 1μm, reaction speed up to 0.3 seconds/time, with temperature compensation, can measure 1-5μm ultra-thin coating.

$309.00
SE
LANDTEK CM8826n dry Film Thickness Gauge measurement of non-metallic coatings on nonmagnetic metallic substrates
Eddy Current0~1250μm±3%
LANDTEK Utility; External Probe, 1250μm; Eddy Current Thickness Measurement; RS232 Interface; Single or Continuous Measurement mode; Wear-resistant hard metal spring guide sleeve probe; optional USB and Bluetooth data output.

$350.00
SE
DONGRU DR360 metal Thickness Gauge, professional measurement of the thickness of coated platings
Magnetic Induction + eddy Current0 ~ 1250µm±1~3%
Dual-function metal Thickness Gauge, thickness range 0~1250 microns, touch button operation, imported metal probe, support zero and two point calibrating, in line with GB/T 4956 standard.

$231.00
SE
CHINA CTG-802-3000F Coating Thickness Gauge
magnetic induction0 ~ 3000μ m±2%
Range 3000 μm, magnetic induction principle, split probe, measurement accuracy ± 2%, super wear-resistant cemented carbide probe, measurement speed up to 0.3 seconds/time.

$257.00
SE
LANDTEK CM8823 film thickness eddy Current Coating Thickness Gauge
eddy current0 ~ 1000µm±3%
Eddy Current thickness measurement principle, split N-type probe, thickness measurement range 0~1000μm, error range +/- 3%, no supporting software, can be used for nonconductive coating testing on aluminum, with automatic shutdown function, can be customized Miscellaneous large range.

$346.00
SE
LANDTEK CM8820 (5mm Range) Cladding Thickness Gauge, Large Range Customized Type
magnetic induction0~5mm±5%
Measurement range 0~5mm, error range +/- 5%, resolution 0.1μm | 1μm, widely used in the measurement of steel, iron and other ferromagnetic metal substrates on non-ferrous magnetic coatings, platings.

$386.00
SE
LANDTEK CM8826Fn paints Thickness Gauge, automatic substrate identification
Magnetic induction + eddy current0 ~ 1250µm±3%
Magnetic Induction and eddy Current paints thickness measurement, with F and N split external probes, thickness measurement range 0~1250μm, error accuracy +/- 3%, LCD screen, with memory calibrated value, automatic identification of different substrates.

$543.00
SE
LANDTEK CM8856 (Bluetooth) platings Thickness Gauge, built-in Bluetooth transmitter function
Magnetic induction + eddy current0 ~ 1250µm±3%

$386.00
SE
LANDTEK CM8829S platings Thickness Gauge F magnetic Induction /NF eddy current Ferromagnetic metal substrates Non-ferrous magnetic coatings, platings
Magnetic induction + eddy current0 ~ 1250µm±3%
Magnetic Induction eddy Current dual function platings thickness measurement, thickness measurement range 0~1250μm, error range +/- 3%, single or continuous measurement, measurement of copper, aluminum, zinc, tin and other substrate enamel, rubber, paints, plastic layer and other film thickness.

$309.00
SE
LANDTEK CM8829F magnetic Thickness Gauge, integrated F magnetic Induction Film Thickness Gauge
magnetic induction0 ~ 1250µm±3%
1250μm thickness measurement; Automatic memory calibrating, magnetic Induction; RS232C interface; optional USB and Bluetooth data output.

$309.00
SE
LANDTEK CM8829n paint Thickness Gauge, integrated eddy current paint Thickness Gauge
eddy current0 ~ 1250µm±3%
Built-in probe, can be operated with one hand; Single and continuous two measurement modes; Automatic memory calibrating; eddy Current thickness measurement; USB and Bluetooth data output can be purchased separately.

If you don't know how to choose "Coating Thickness Gauge", please consult customer service.