Qiwei PHS-3E desktop microcomputer pH meter -2~ 18pH
Simultaneous measurement of pH value, mV value, temperature value, using composite electrode, high sensitivity, automatic temperature compensation, data storage, large range of -2~ 18pH
QiWei-
BANTE P22 pH electrode for measurement of high temperature samples
$ 357.00 -
BANTE PHS-3CW-CN Laboratory pH Meter 0.00~14.00pH
$ 257.00 -
BANTE A130-UK Laboratory pH Meter Acid alkalinity Detector
$ 626.00 -
DDKSIC 201T-H triple composite pH electrode environmental protection, chemical industry, energy, conventional water sample measurement
$ 112.00 -
Shima AS218 PH value Detector 0.00~14.00
$ 150.00
product description
Qiwei PHS-3E PH meter (desktop microcomputer) is a PH meter with a relatively large measuring range, the measuring range is -2 ~ 18pH . Data storage and extraction, automatic temperature compensation, convenient and simple operation, stable measurement data.
Principle
Glass electrodes are often used to measure the pH value of aqueous solutions. The head of the pH glass electrode is made of a special sensitive film, which is sensitive to hydrogen ions. Concentration and temperature vary. When the solution temperature is 25°C, the electrode potential changes by 59.16mV for every pH change. That is, the theoretical slope coefficient of the electrode.
The glass electrode is used as the indicating electrode, and since its potential does not change with the concentration of hydrogen ions in the measured solution, the reference electrode is generally a calomel electrode. When the hydrogen ion concentration (strictly speaking, the activity) in the solution, that is, the pH value of the solution changes, the potential generated between the glass electrode and the calomel electrode also changes, and the potential change relationship conforms to the following formula:
△E=-58.16×△pH×(273+t℃)/293(mV)
△E: Indicates the change in potential in millivolts. (mV)
△pH: Indicates the change of the pH value of the solution.
t: Indicates the temperature of the solution to be measured (°C).
The measurement of pH value measures the potential difference between two electrodes. When the potential difference generated by a pair of electrodes in the solution is equal to zero, the pH value of the measured solution is the zero potential pH value, which is related to the solution in the glass electrode. The PHS-3E pH meter is equipped with a composite electrode composed of a glass electrode and an Ag-Agcl electrode, and its zero point pH value is 7±0.25pH.
Pictures



QiWei PHS-3E pH meter (desktop microcomputer)Specifications
| LIST | VALUE |
|---|---|
| PH range | -2~18pH |
| PH measurement Accuracy | ±0.01/0.1pH |
| resolution | pH: 0.01pH/Temperature: ± 1 ℃ |
| Temperature Measurement range | 0~100℃ |
| Stability (zero drift) | ≤ 0.01pH ± 1 word/2h |
| data storage | With data storage function |
| Power | 9V DC Power |
| Dimensions | 230*200*60mm |
| Weight | About 1.5Kg |
| Standard electrode reagent | E201-C-L Glass PH composite electrode (suitable for solution temperature measurement in the range of 0-100 ℃); temperature electrode (only suitable for solution use in the range of 0-65 ℃); pH buffer; power adapter |
| Allowable environment temperature | 0~40℃ |
| Allowable Relative Humidity | <85% |
| input impedance | > 1x1012OH |
| Solution temperature compensation range | 5~60℃ |
| Temperature measurement Accuracy | ±1℃ |
| Temperature compensation method | Automatic/Manual |
| mV range | ±1000mV |
QiWei PHS-3E pH meter (desktop microcomputer) Packing list
Host x1, Buffer reagent x3, Encasement box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 3324-2024
- ActiveGB/T 44332-2024
- ActiveGB/T 2394-2024
- ActiveJJF 1575-2016
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 1601-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010
- ActiveGB/T 2390-2013
- ActiveGB/T 3780.7-2016


PHS-3E