Qiwei PH-20 pen pH meter pH range 0.1~ 14pH
Qiwei PH-20 pH meter is a pen acidity meter with an accurate measurement of ± 0.1pH, which can measure pH and temperature at the same time. The PH-20 pen acidity meter is a built-in electrode, which is suitable for monitoring tap water, aquaculture, environmental protection, agriculture, printing and dyeing and other fields.
QiWei-
HANNA HI99171 Waterproof Portable pH Meter for leather/paper
$ 997.00 -
FANGZHOU PHBJ-360F Portable pH Meter ph Portable acidity meter 0.001 grade
$ 695.00 -
HANNA HI13302 Bluetooth ultra-fine Glass acidity electrode testtube
$ 757.00 -
LEICI 962242 Planar pH composite electrode for surfaces or droplet samples
$ 243.00 -
FANGZHOU FZ-241-3A Small container pH electrode micro sample test
$ 350.00
Introduction
Qiwei PH-20 is a pen-type acidity meter, the measurement accuracy is ±0.1pH, and it can measure PH value and temperature value at the same time. The PH-20 pen-type acidity meter is small in size and easy to carry, and is often used in outdoor or field test operations. It is suitable for monitoring the pH value of tap water, aquaculture, environmental protection, agriculture, printing and dyeing, electroplating, beverages and scientific research units, and the measurement is accurate and reliable. Among them, the PH-20 pen-type acidity meter is a built-in electrode.
Pictures



QiWei PH-20 PH Meter (pen)Specifications
| LIST | VALUE |
|---|---|
| PH range | 0.1~14pH |
| PH measurement Accuracy | ±0.1pH |
| Power | 1.5V battery (LR44) * 4PCS |
| Dimensions | F40 * 185mm |
| Weight | 88g |
| Allowable environment temperature | 0~50℃ |
| resolution | 0.1pH |
| PH calibrated | PH: 25 ℃ three point calibrated (4.0, 6.9, 9.2) |
| temperature resolution | 0.1℃(1℉) |
| Temperature measurement Accuracy | 1℃ |
| Temperature Measurement range | 0~50℃/32~122℉ |
QiWei PH-20 PH Meter (pen) Packing list
Host x1, Buffer reagent x3, Encasement box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 3324-2024
- ActiveGB/T 2394-2024
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- Active 098-2007
- ActiveGB/T 1601-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010
- ActiveGB/T 2390-2013
- ActiveGB/T 3780.7-2016
- ActiveGB/T 14518-1993


PH-20