FANGRUI CH2015 thermostatic bath, volume 15 L, temperature range RT + 15~ 150 ℃
FANGRUI CH2015 thermostatic bath is a constant temperature circulating water and Oil Bath with a display resolution of 0.1 ℃. Temperature fluctuation is ± 0.05 ℃. The CH2015 thermostatic bath adopts a temperature control method of microcomputer temperature control and self-tuning PID adjustment.
FangRui-
BOZHEN BZ-301 Low temperature Thermostatic Water Bath -10~95 ℃/15L
$ 1555.00 -
NELE HTS-300B standard verification water & oil Tank, with oil rapid cooling
$ 2850.00 -
LEPTO iCooler- 4009 + external circulation thermostat circulator
Login -
Shangtian Jingyi DC-0510N (0.01) Low temperature Thermostatic Bath Electric cooling Thermostatic Bath -5 ℃/10L
$ 1349.00 -
Kenton DC-10/10 low temperature circulating water tank -10 ℃/10L
$ 1328.00
Introduction
FANGRUIs CH2015 constant temperature bath is a microcomputer temperature-controlled constant temperature Water Bath (Oil Bath). It adopts a new high-performance single-chip microcomputer control, self-tuning PID adjustment, and uses imported temperature sensors to measure temperature, with high temperature control accuracy and small fluctuations; imported stirring Motor, low noise and long life. It adopts a large-screen backlit LCD display, and the parameters are clear and clear, beautiful and fashionable. The temperature control of the instrument is accurate, stable and reliable, and the operation is convenient and safe.
Features
1. Adopt high-performance single-chip microcomputer control, PID adjustment, and self-tuning control technology, with high temperature control accuracy and short stabilization time;
2. It has the protection function of breaking the coupler to prevent the instrument from getting out of control;
3. The upper limit over-temperature alarm function can be set by yourself, and if it exceeds the range, it will alarm immediately;
4. The instrument works stably and reliably, and the operation is very convenient;
5. Large-screen backlit LCD, all parameters are clear and beautiful;
6. The Circulating Chiller can lead the constant temperature liquid in the tank to the outside to establish a second constant temperature field;
7. The liner and table are made of high-quality stainless steel, which is corrosion-resistant and easy to clean.
Application
The CH2015 constant temperature bath can not only carry out the constant temperature test directly in the Water Tank, but also use the external circulation function to guide the controlled constant temperature liquid in the tank to other equipment (such as viscometer, density meter, Surface Tensiometer, polarimeter, rotary evaporator, Spectrophotometer , etc.).
CH2015 constant temperature bath is widely used in bioengineering, medicine, food, chemical industry, metallurgy, chemical analysis, petroleum and other fields, providing users with a high-precision, controlled, and uniform temperature constant field source. , factory laboratories, and quality inspection departments are satisfied with the constant temperature device.
Pictures

FangRui CH2015 ThermostatSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | RT+15~200°C |
| Temperature fluctuation | ± 0.05℃ |
| temperature resolution | 0.1℃ |
| Tank Volume | 15L |
| Tank opening Dimensions | 235*140*180mm |
| Temperature control method | Microcomputer temperature control, self-tuning PID adjustment |
| Circular mode | Internal/external circulation |
| Heating power | 2200W |
| Dimensions | 340*280*430mm |
| Pump flow | 10L/min |
| Complete-built unit net Weight | 10Kg |
| Low level protection | without |
FangRui CH2015 Thermostat Packing list
Host x1, cover x1, silicone tube x1, power cord x1, manual, certificate of conformity, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Viscosity Determination of Eccentric Falling Ball Determination
- Instructions for assembly and use of Thermostat
- Thermostat structure and working principle introduction
- 0.01 ℃ High Precision Low Temperature Thermostat
- How to assemble and use Thermostat
- ActiveJJF 2019-2022
- ActiveJJF 1030-2023
- ActiveGB/T 28853-2012
- ActiveGB/T 32710.5-2016
- ActiveJJF 1030-2010
- ActiveGB/T 26808-2011
- ActiveGB/T 2005-19787
- ActiveGB/T 18856.4-2008
- ActiveFZ/T 50010.3-2011
- ActiveHG/T 3660-1999
- ActiveJB/T 9518-1999
- ActiveGB 9278-2008
- ActiveGB/T 5561-2012


CH2015
CH1515