LEICI PHSJ-3F Laboratory pH Meter Class 0.01, Potential/pH/Temperature
The LEICI PHSJ-3F acid alkalinity Tester has a resolution of 0.01 pH respectively, and has a reminder function of electrode performance and calibration. It is a desktop smart acidity instrument.
LeiCi-
Online pH meter QIWEI PH-110 0~14pH
$ 148.00 -
E-PHScan-FT-100K pH electrode
$ 102.00 -
LEICI 962121 Low Conductivity Detector pH composite electrode for low conductivity water samples with conductivity above 100 µS/cm
$ 200.00 -
Qiwei PHS-3DW pH meter (desktop microcomputer)
$ 187.00 -
BANTE A120-UK Laboratory pH Tester
$ 554.00










Introduction
Leici PHSJ-3F pH Tester is an intelligent desktop pH meter with a measurement accuracy of 0.01 and a measurement temperature accuracy of 0.1℃. It is used in laboratories to detect the pH value of solutions and determine the quality of products. In terms of accuracy design, the PHSJ-3F pH Tester adds electrode performance and calibration reminder functions to improve the accuracy of measurement. There are three reading functions: Smart, Timed, and Cont for users to choose from. In addition, the pH Tester can not only measure PH value, but also temperature value and mv value. It is multi-functional and has wider applicability.
Features
1. Three reading mode functions: Smart-Read mode can intelligently determine the end point and facilitate reading; Timed-Read mode can automatically store data through timing ; Cont-Read mode allows users to clearly understand the continuous change process of the sample and achieve continuous intervals. Measurement.
2. Thundermagnetic PHSJ-3F/pH Tester realizes electrode MI and calibration reminder functions, and the measurement is accurate.
3. The measurement information complies with GLP specifications and can be completely traced.
a. Set the operator number and record the operator's operation process;
b. Realize record review and print calibration data;
c. Achieve viewing, deletion, printing and storage of measurement data;
d. Measurement data can be stored up to 500 sets and complies with GLP specifications.
4. The measurement value, temperature value, measurement mode, electrode slope, equipotential value, operation time and date are displayed on the large dot matrix LCD. The content is clear and comprehensive.
5. Achieve automatic calibration, automatic temperature compensation, automatic identification of 5 buffer solutions, and can be calibrated at 1-3 points.
6. The PHSJ-3F pH Tester has 3 isoelectric points to choose from, and can easily measure the PH value of pure water, boiler water, ultrapure water, etc.
7. The PC panel uses new materials and the touch digital keyboard is durable.
8. High data security and power-off protection.
9. USB communication interface and REX data acquisition software can be used.
10. Chinese operation interface and well-designed human-machine interface.
LeiCi PHSJ-3F pH meterSpecifications
| LIST | VALUE |
|---|---|
| Instrument level | Level 0.01 |
| Measurement parameters | Potential, pH and temperature |
| mV range | -2000.0~2000.0mV |
| mV resolution | 0.1mV |
| mV electronic unit error of indication | +/- 0.1% or +/- 0.3 mV |
| PH range | (-2.00~20.00)pH |
| pH resolution | 0.01pH |
| An indication of pH electronic unit error | ±0.01pH |
| Temperature range | (-5.0~110.0)℃ /(23.0-230.0)℉ |
| Temperature Resolution | 0.1℃/0.1℉ |
| Temperature electronic unit error of indication | ±0.2 ℃ |
| Power | Power adapter (input: AC100~240V, output: DC9V) |
| Dimensions | 242*195*68mm |
| Weight | 0.9kg |
LeiCi PHSJ-3F pH meter Packing list
pH meter x1, E-301F composite pH electrode x1, general power supply (9VDC, 800mA, inner positive and outer negative) x1, REX-3 multifunctional electrode holder x1, pH standard buffer pH4.00/6.86/9.18 each x5, USB communication connection x1, REXDC2.0 LEICI data collection software x1, dust cover x1, manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Acidity Meter Operation Application Instructions
- Uncertainty measurement experiment introduced by different levels of pHmeter
- How to choose the right PH electrode? [Selection Guide]
- Classification of common acidity meters on the market
- Glass electrode of pH acidity meter should be selected correctly
- Analysis and measures of influencing factors of online detection error of pure water pHmeter
- Maintenance technology of acidity meter (detailed introduction)
- Acidity meter operation instructions
- The function of temperature compensator of pH meter and its influence on pH value
- Analysis of Influencing Factors on pH Value Test Results of Chemical Products
- ActiveGB/T 3324-2024
- ActiveGB/T 44332-2024
- ActiveGB/T 2394-2024
- ActiveJJF 1575-2016
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 1601-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010
- ActiveGB/T 2390-2013
- ActiveGB/T 3780.7-2016


PHSJ-3F