LEICI PHS-3G PH Tester with Stirring Automatic calibration Manual warming pH + mV
Automatic calibration manual temperature compensation with stirring, Measurement parameters pH, mV, PH measurement range -2.00~19.99pH, PH measurement accuracy +/- 0.01pH, resolution 0.01pH/1mV, dynamic identification of 3 standard buffer solutions 4.00pH, 6.86pH, 9.18pH
LeiCi-
PHSCAN30F-K pen pHmeter for semi-solid measurement
$ 158.00 -
AOLILONG PHB-10 pen pH meter laboratory test site, water quality assurance, industrial and mining production process and other ph value monitoring
$ 110.00 -
FANGZHOU PHS-3C + economical acidity meter pH/mV/ORP/temperature value 0.01 grade
$ 406.00 -
LEICI T-817-B-6 temperature electrode
$ 125.00 -
LEICI 962223 RoHS pH composite electrode for RoHS compliance
$ 242.00








Leici PHS-3G ph Tester is a desktop pH meter used to test the pH value of laboratory solutions. The measurement results are displayed through a large-screen LCD segment code LCD. Different from ordinary pH meters, the PHS-3G pH Tester has an electromagnetic stirring function, which can not only measure the pH value of the solution, but also automatically stir the solution, making it a dual-use machine. The PHS-3G pH meter has two-point calibration, automatically identifies three standard buffer solutions, and simultaneously measures pH and mV values. The measurement resolution is 0.01pH.
Features
1. Leici PHS-3G ph Tester is equipped with electromagnetic stirring.
2. The pH Tester can automatically identify and calibrate the buffer solution to achieve two-point calibration.
3. Manually perform temperature compensation.
4. The pH composite electrode provided with PHS-3G is type E-201-C-Q9.
5. LCD segment type liquid crystal display, digital display, intuitive and clear.
LeiCi PHS-3G pH meterSpecifications
| LIST | VALUE |
|---|---|
| Instrument level | 0.01 level |
| Measurement parameter | PH value, mV (ORP) |
| Measurement range pH | (-2.00~19.99)pH |
| Measurement range mV | (-1999~1999)mV |
| pH resolution | 0.01pH |
| Resolution mV | 1mV |
| Intrinsic error pH | ±0.01pH |
| Intrinsic error mV | ±0.1%FS |
| Stability | (+/- 0.01pH +/- 1 word)/3h |
| temperature compensation | Manual (0.0~60.0) ℃ |
| Power Supply | AC (220±22)V,(50±1 )Hz |
| Size (mm), Weight (kg) | 210×320×95,2 |
| Standard electrode | E-201F pH composite electrode |
| Measurement range of standard electrode | (0.00~14.00)pH |
LeiCi PHS-3G pH meter Packing list
HS-3G type pH Meter X1, E-201-C type pH composite electrode X1, electrode stem X1, electrode clip X1, three-core power cord (standard universal) X1, buffering reagent pH4/6.86/9. 18X5, stirring beads (small) X3, fuse BGXP φ 5 × 200.5AX2, instruction manual, product certificate
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Glass electrode of pH acidity meter should be selected correctly
- The function of temperature compensator of pH meter and its influence on pH value
- Acidity meter operation instructions
- Maintenance technology of acidity meter (detailed introduction)
- Analysis and measures of influencing factors of online detection error of pure water pHmeter
- Detailed explanation of the application principle of pH meter
- Classification of common acidity meters on the market
- Acidity Meter Operation Application Instructions
- Analysis of Influencing Factors on pH Value Test Results of Chemical Products
- Types and problems of pH meter automatic cleaning instrument
- ActiveGB/T 3324-2024
- ActiveGB/T 44332-2024
- ActiveGB/T 2394-2024
- ActiveJJF 1575-2016
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 1601-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010
- ActiveGB/T 2390-2013
- ActiveGB/T 3780.7-2016


PHS-3G